Part Number Hot Search : 
237A1ACM DS2505P AD9844A A5C10 ECCM9 P1500ECL MBR102 MJE5731G
Product Description
Full Text Search
 

To Download 1990114 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
PM7385
FREEDMTM-84A672
FRAME ENGINE AND DATALINK MANAGER 84A672
DATA SHEET
PROPRIETARY AND CONFIDENTIAL ISSUE 6: AUGUST 2001
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
REVISION HISTORY
Issue No. Issue 1 Issue 2 Issue 3 Issue 4 Issue Date Jan 7, 1999 July 8, 1999 January, 2000 June 2000 Details of Change Creation of Document. Update as per issue 3 of the engineering document (PMC981263). Update as per issue 4 of the engineering document (PMC981263), for GCA release. Re-issue to coincide with production release of Rev C of device. Minor corrections and changes to some DC and AC timing parameters. Re-issue to coincide with Issue 6 of the Eng Doc. DEFAULT_DRV register bit changed to PERM_DRV and description changed. (See PREP #4938.) Change bars have been kept to show both Issue 4 and Issue 5 changes. Issue 6 August 2001 Patent information included. Change bars apply to previous issue.
Issue 5
October 2000
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
i
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
CONTENTS 1 2 3 4 5 6 7 8 FEATURES...............................................................................................1 APPLICATIONS ........................................................................................3 REFERENCES .........................................................................................4 BLOCK DIAGRAM....................................................................................5 DESCRIPTION .........................................................................................6 PIN DIAGRAM ..........................................................................................9 PIN DESCRIPTION ................................................................................10 FUNCTIONAL DESCRIPTION................................................................39 8.1 8.2 8.3 8.4 SCALEABLE BANDWIDTH INTERCONNECT (SBI) INTERFACE39 HIGH-LEVEL DATA LINK CONTROL (HDLC) PROTOCOL.........40 SBI EXTRACTER AND PISO.......................................................41 RECEIVE CHANNEL ASSIGNER ................................................41 8.4.1 8.4.2 8.4.3 8.4.4 8.5 Line Interface .................................................................43 Priority Encoder .............................................................44 Channel Assigner ..........................................................44 Loopback Controller.......................................................44
RECEIVE HDLC PROCESSOR / PARTIAL PACKET BUFFER ...44 8.5.1 8.5.2 HDLC Processor............................................................45 Partial Packet Buffer Processor .....................................45
8.6
RECEIVE ANY-PHY INTERFACE ................................................47 8.6.1 8.6.2 FIFO Storage and Control..............................................48 Polling Control and Management...................................49
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
ii
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
8.7
TRANSMIT ANY-PHY INTERFACE .............................................49 8.7.1 8.7.2 FIFO Storage and Control..............................................49 Polling Control and Management...................................50
8.8
TRANSMIT HDLC CONTROLLER / PARTIAL PACKET BUFFER52 8.8.1 8.8.2 Transmit HDLC Processor .............................................52 Transmit Partial Packet Buffer Processor ......................53
8.9
TRANSMIT CHANNEL ASSIGNER..............................................55 8.9.1 8.9.2 8.9.3 Line Interface .................................................................57 Priority Encoder .............................................................57 Channel Assigner ..........................................................58
8.10 8.11 8.12 8.13 9
SBI INSERTER AND SIPO ..........................................................58 PERFORMANCE MONITOR .......................................................59 JTAG TEST ACCESS PORT INTERFACE...................................59 MICROPROCESSOR INTERFACE .............................................59
NORMAL MODE REGISTER DESCRIPTION ........................................64 9.1 MICROPROCESSOR ACCESSIBLE REGISTERS .....................64
10
TEST FEATURES DESCRIPTION .......................................................181 10.1 10.2 TEST MODE REGISTERS.........................................................181 JTAG TEST PORT .....................................................................183 10.2.1 10.2.2 Identification Register ..................................................183 Boundary Scan Register ..............................................184
11
OPERATIONS.......................................................................................201 11.1 JTAG SUPPORT........................................................................201
12
FUNCTIONAL TIMING..........................................................................208
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
iii
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
12.1 12.2 12.3 12.4 12.5 12.6 13 14 15 16 17
SBI DROP BUS INTERFACE TIMING .......................................208 SBI ADD BUS INTERFACE TIMING ..........................................209 RECEIVE LINK TIMING .............................................................209 TRANSMIT LINK TIMING ..........................................................210 RECEIVE APPI TIMING .............................................................210 TRANSMIT APPI TIMING ..........................................................214
ABSOLUTE MAXIMUM RATINGS........................................................218 D.C. CHARACTERISTICS....................................................................219 FREEDM-84A672 TIMING CHARACTERISTICS .................................221 ORDERING AND THERMAL INFORMATION ......................................233 MECHANICAL INFORMATION.............................................................234
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
iv
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
LIST OF FIGURES FIGURE 1 - HDLC FRAME...............................................................................40 FIGURE 2 - CRC GENERATOR.......................................................................41 FIGURE 3 - PARTIAL PACKET BUFFER STRUCTURE ..................................46 FIGURE 4 - PARTIAL PACKET BUFFER STRUCTURE ..................................53 FIGURE 5 - INPUT OBSERVATION CELL (IN_CELL) ...................................198 FIGURE 6 - OUTPUT CELL (OUT_CELL)......................................................199 FIGURE 7 - BI-DIRECTIONAL CELL (IO_CELL)............................................199 FIGURE 8 - LAYOUT OF OUTPUT ENABLE AND BI-DIRECTIONAL CELLS200 FIGURE 9 - BOUNDARY SCAN ARCHITECTURE ........................................202 FIGURE 10 - TAP CONTROLLER FINITE STATE MACHINE ........................204 FIGURE 11 - T1/E1 DROP BUS FUNCTIONAL TIMING ................................208 FIGURE 12 - DS3 DROP BUS FUNCTIONAL TIMING ..................................208 FIGURE 13 - DS3 ADD BUS ADJUSTMENT REQUEST FUNCTIONAL TIMING ..............................................................................................................209 FIGURE 14 - RECEIVE LINK TIMING ............................................................210 FIGURE 15 - TRANSMIT LINK TIMING .........................................................210 FIGURE 16 - RECEIVE APPI TIMING (NORMAL TRANSFER) ..................... 211 FIGURE 17 - RECEIVE APPI TIMING (AUTO DESELECTION) ....................212 FIGURE 18 - RECEIVE APPI TIMING (OPTIMAL RESELECTION)...............213 FIGURE 19 - RECEIVE APPI TIMING (BOUNDARY CONDITION) ...............214 FIGURE 20 - TRANSMIT APPI TIMING (NORMAL TRANSFER)...................215 FIGURE 21 - TRANSMIT APPI TIMING (SPECIAL CONDITIONS)................216 FIGURE 22 - TRANSMIT APPI TIMING (POLLING).......................................217
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
v
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
FIGURE 23 - SBI FRAME PULSE TIMING.....................................................222 FIGURE 24 - SBI DROP BUS TIMING ...........................................................223 FIGURE 25 - SBI ADD BUS TIMING ..............................................................224 FIGURE 26 - SBI ADD BUS COLLISION AVOIDANCE TIMING ....................224 FIGURE 27 - RECEIVE DATA TIMING ...........................................................225 FIGURE 28 - TRANSMIT DATA TIMING.........................................................225 FIGURE 29 - RECEIVE ANY-PHY PACKET INTERFACE TIMING.................227 FIGURE 30 - TRANSMIT ANY-PHY PACKET INTERFACE TIMING ..............228 FIGURE 31 - MICROPROCESSOR READ ACCESS TIMING .......................229 FIGURE 32 - MICROPROCESSOR WRITE ACCESS TIMING......................231 FIGURE 33 - JTAG PORT INTERFACE TIMING............................................232 FIGURE 34 - 352 PIN ENHANCED BALL GRID ARRAY (SBGA) ..................234
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
vi
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
LIST OF TABLES TABLE 1 - SBI INTERFACE SIGNALS (30)......................................................10 TABLE 2 - CLOCK/DATA INTERFACE SIGNALS (15) .....................................16 TABLE 3 - ANY-PHY PACKET INTERFACE SIGNALS (70) .............................18 TABLE 4 - MICROPROCESSOR INTERFACE SIGNALS (31).........................30 TABLE 5 - MISCELLANEOUS INTERFACE SIGNALS (111)............................32 TABLE 6 - PRODUCTION TEST INTERFACE SIGNALS (31)..........................34 TABLE 7 - POWER AND GROUND SIGNALS (64)..........................................36 TABLE 8 - SBI SPE/TRIBUTARY TO RCAS LINK MAPPING...........................42 TABLE 9 - TRANSMIT POLLING......................................................................51 TABLE 10 - SBI SPE/TRIBUTARY TO TCAS LINK MAPPING .........................55 TABLE 11 - NORMAL MODE MICROPROCESSOR ACCESSIBLE REGISTERS59 TABLE 12 - SPE TYPE CONFIGURATION ......................................................90 TABLE 13 - FASTCLK FREQUENCY SELECTION..........................................91 TABLE 14 - SPE TYPE CONFIGURATION ......................................................92 TABLE 15 - FASTCLK FREQUENCY SELECTION..........................................93 TABLE 16 - SBI MODE SPE1 CONFIGURATION ..........................................100 TABLE 17 - SBI MODE SPE2 CONFIGURATION ..........................................103 TABLE 18 - SBI MODE SPE3 CONFIGURATION ..........................................106 TABLE 19 - CRC[1:0] SETTINGS................................................................... 115 TABLE 20 - CRC[1:0] SETTINGS...................................................................126 TABLE 21 - FLAG[2:0] SETTINGS .................................................................131 TABLE 22 - LEVEL[3:0]/TRANS SETTINGS ..................................................133
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
vii
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
TABLE 23 - SBI MODE SPE1 CONFIGURATION ..........................................147 TABLE 24 - SBI MODE SPE2 CONFIGURATION ..........................................150 TABLE 25 - SBI MODE SPE3 CONFIGURATION ..........................................153 TABLE 26 - TRIB_TYP ENCODING ...............................................................168 TABLE 27 - TRIB_TYP ENCODING ...............................................................180 TABLE 28 - TEST MODE REGISTER MEMORY MAP...................................182 TABLE 29 - INSTRUCTION REGISTER.........................................................183 TABLE 30 - BOUNDARY SCAN CHAIN .........................................................184 TABLE 31 - FREEDM-84A672 ABSOLUTE MAXIMUM RATINGS .................218 TABLE 32 - FREEDM-84A672 D.C. CHARACTERISTICS .............................219 TABLE 33 - CLOCKS AND SBI FRAME PULSE (FIGURE 23).......................221 TABLE 34 - SBI DROP BUS (FIGURE 24) .....................................................222 TABLE 35 - SBI ADD BUS (FIGURE 25 TO FIGURE 26)...............................223 TABLE 36 - CLOCK/DATA INPUT (FIGURE 27).............................................225 TABLE 37 - CLOCK/DATA OUTPUT (FIGURE 28).........................................225 TABLE 38 - ANY-PHY PACKET INTERFACE (FIGURE 29 TO FIGURE 30) ..226 TABLE 39 - MICROPROCESSOR INTERFACE READ ACCESS (FIGURE 31) ..............................................................................................................228 TABLE 40 - MICROPROCESSOR INTERFACE WRITE ACCESS (FIGURE 32) ..............................................................................................................230 TABLE 41 - JTAG PORT INTERFACE (FIGURE 33)......................................231 TABLE 42 - FREEDM-84A672 ORDERING INFORMATION..........................233 TABLE 43 - FREEDM-84A672 THERMAL INFORMATION ............................233
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
viii
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
1
FEATURES * Single-chip multi-channel HDLC controller with a 50 MHz, 16 bit "Any-PHY" Packet Interface (APPI) for transfer of packet data using an external controller. Supports up to 672 bi-directional HDLC channels assigned to a maximum of 84 channelised or unchannelised links conveyed via a Scaleable Bandwidth Interconnect (SBI) interface. Data on the SBI interface is divided into 3 Synchronous Payload Envelopes (SPEs). Each SPE can be configured independently to carry data for either 28 T1/J1 links, 21 E1 links, or 1 unchannelised DS-3 link. Links in an SPE can be configured individually to operate in clear channel mode, in which case, all framing bit locations are assumed to be carrying HDLC data. Links in an SPE can be configured individually to operate in channelised mode, in which case, the number of time-slots assigned to an HDLC channel is programmable from 1 to 24 (for T1/J1 links) and from 1 to 31 (for E1 links). Supports three bi-directional HDLC channels each assigned to an unchannelised link with arbitrary rate link of up to 51.84 MHz when SYSCLK is running at 45 MHz. Each link may be configured individually to replace one of the SPEs conveyed on the SBI interface. For each channel, the HDLC receiver supports programmable flag sequence detection, bit de-stuffing and frame check sequence validation. The receiver supports the validation of both CRC-CCITT and CRC-32 frame check sequences. For each channel, the receiver checks for packet abort sequences, octet aligned packet length and for minimum and maximum packet length. The receiver supports filtering of packets that are larger than a user specified maximum value. Alternatively, for each channel, the receiver supports a transparent mode where each octet is transferred transparently on the receive APPI. For channelised links, the octets are aligned with the receive time-slots. For each channel, time-slots are selectable to be in 56 kbits/s format or 64 kbits/s clear channel format.
*
*
*
*
*
*
*
*
*
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
1
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
*
For each channel, the HDLC transmitter supports programmable flag sequence generation, bit stuffing and frame check sequence generation. The transmitter supports the generation of both CRC-CCITT and CRC-32 frame check sequences. The transmitter also aborts packets under the direction of the external controller or automatically when the channel underflows. Alternatively, for each channel, the transmitter supports a transparent mode where each octet is inserted transparently from the transmit APPI. For channelised links, the octets are aligned with the transmit time-slots. Supports per-channel configurable APPI burst sizes of up to 256 bytes for transfers of packet data. The FREEDM maintains packet level performance metrics such as number of received packets, number of received packets with frame check sequence errors, number of transmitted packets, number of receive aborted packets, and number of transmit aborted packets. Provides 32 Kbytes of on-chip memory for partial packet buffering in both the transmit and the receive directions. This memory may be configured to support a variety of different channel configurations from a single channel with 32 Kbytes of buffering to 672 channels, each with a minimum of 48 bytes of buffering. Provides a 16 bit microprocessor interface for configuration and status monitoring. Provides a standard 5 signal P1149.1 JTAG test port for boundary scan board test purposes. Supports 3.3 Volt tolerant I/O. Low power 2.5 Volt 0.25 mm CMOS technology. 352 pin enhanced ball grid array (SBGA) package.
*
* *
*
* * * * *
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
2
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
2
APPLICATIONS * * * * * * * IETF PPP interfaces for routers Frame Relay interfaces for ATM or Frame Relay switches and multiplexors FUNI or Frame Relay service inter-working interfaces for ATM switches and multiplexors. Internet/Intranet access equipment. Packet-based DSLAM equipment. Packet over SONET. PPP over SONET.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
3
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
3
REFERENCES
1. International Organization for Standardization, ISO Standard 3309-1993, "Information Technology - Telecommunications and information exchange between systems - High-level data link control (HDLC) procedures - Frame structure", December 1993. 2. RFC-1662 - "PPP in HDLC-like Framing" Internet Engineering Task Force, July 1994. 3. PMC-1981125 - "High Density T1/E1 Framer with Integrated VT/TU Mapper and M13 Multiplexer (TEMUX) Data Sheet", PMC-Sierra Inc.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
4
4
DATA SHEET
PMC-1990114
FASTCLK R EFC LK RSTB SPE1_EN SPE3_EN SPE2_EN SYSC LK
C1FP
BLOCK DIAGRAM
C 1FPOUT PM C TEST
RCLK[2:0] RD[2:0] SBI PISO SBI PISO SBI PISO Performance Monitor (PMON) Receive Channel Assigner (R CAS672) Receive HDLC Processor / Partia l Packet Buffer (RHDL672) Receive Any-PHY Packet Inte rface (RAPI672)
ISSUE 6
DDATA[7:0] DPL DV5 DD P
SB I Extract
RXCLK RXADDR[2:0] RPA REN B RXDATA[1 5:0] RXP RTY RSX REOP RMOD RERR RVAL
SBI SIPO SBI SIPO SBI SIPO Tra nsm it Channel Assigner (TCAS672) Transmit HD LC Processor / Partia l Packet Buffer (THD L672)
ADATA[7:0] APL AV5 AD P AJUST_REQ AACTIVE ADETEC T[1:0]
SBI Insert
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
TCLK[2:0] TD[2:0] Microprocessor Inte rface JTAG Port
Tra nsm it Any-PHY Packet Inte rface (TAPI6 72)
TXCLK TXADD R[12:0] TPA1[2:0] TPA2[2:0 ] TR D Y TXD ATA[15 :0 ] TXPR TY TSX TEO P TMO D TER R
84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
5
PM7385 FREEDM-84A672
IN TB RDB W RB CSB ALE A[11:2] D[15:0]
TD O TD I TC K TM S TR STB
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
5
DESCRIPTION The PM7385 FREEDM-84A672 Frame Engine and Datalink Manager device is a monolithic integrated circuit that implements HDLC processing for a maximum of 672 bi-directional channels. The FREEDM-84A672 may be configured to support channelised T1/J1/E1 or unchannelised traffic on up to 84 links conveyed via a Scaleable Bandwidth Interconnect (SBI) interface. The SBI interface transports data in three Synchronous Payload Envelopes (SPEs), each of which may be configured independently to carry either 28 T1/J1 links, 21 E1 links or a single DS-3 link. For channelised T1/J1/E1 links, the FREEDM-84A672 allows up to 672 bidirectional HDLC channels to be assigned to individual time-slots within each independently timed T1/J1 or E1 link. The channel assignment supports the concatenation of time-slots (N x DS0) up to a maximum of 24 concatenated timeslots for a T1/J1 link and 31 concatenated time-slots for an E1 link. Time-slots assigned to any particular channel need not be contiguous within a T1/J1 or E1 link. Unchannelised DS-3 links are assigned to a single HDLC channel. Additionally, links may be configured independently to operate in an unframed or "clear channel" mode, in which the bit periods which are normally reserved for framing information in fact carry HDLC data. In unframed mode, links operate as unchannelised (i.e. the entire link is assigned to a single HDLC channel) regardless of link rate. The FREEDM-84A672 supports mixing of channelised T1/J1/E1 and unchannelised or unframed links. The total number of channels in each direction is limited to 672. The maximum possible data rate over all links is 134.208 Mbps (which occurs with three DS-3 links running in unframed mode). The FREEDM-84A672 supports three independently timed bidirectional clock/ data links, each carrying a single unchannellised HDLC stream. The links can be of arbitrary frame format and can operate at up to 51.84 MHz provided SYSCLK is running at 45 MHz. When activated, each link replaces one of the SPEs conveyed on the SBI interface. (The maximum possible data rate when all three clock/data links are activated is 155.52 Mbps.) The FREEDM-84A672 provides a low latency "Any-PHY" packet interface (APPI) to allow an external controller direct access into the 32 Kbyte partial packet buffers. Up to seven FREEDM-84A672 devices may share a single APPI. For each of the transmit and receive APPI, the external controller is the master of the FREEDM-84A672 device sharing the APPI from the point of view of device
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
6
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
selection. The external controller is also the master for channel selection in the transmit direction. In the receive direction, however, each FREEDM-84A672 device retains control over selection of its respective channels. The transmit and receive APPI is made up of three groups of functional signals - polling, selection and data transfer. The polling signals are used by the external controller to interrogate the status of the transmit and receive 32 Kbyte partial packet buffers. The selection signals are used by the external controller to select a FREEDM84A672 device, or a channel within a FREEDM-84A672 device, for data transfer. The data transfer signals provide a means of transferring data across the APPI between the external controller and a FREEDM-84A672 device. In the receive direction, polling and selection are done at the device level. Polling is not decoupled from selection, as the receive address pins serve as both a device poll address and to select a FREEDM-84A672 device. In response to a positive poll, the external controller may select that FREEDM-84A672 device for data transfer. Once selected, the FREEDM-84A672 prepends an in-band channel address to each partial packet transfer across the receive APPI to associate the data with a channel. A FREEDM-84A672 must not be selected after a negative poll response. In the transmit direction, polling is done at the channel level. Polling is completely decoupled from selection. To increase the polling bandwidth, up to two channels may be polled simultaneously. The polling engine in the external controller runs independently of other activity on the transmit APPI. In response to a positive poll, the external controller may commence partial packet data transfer across the transmit APPI for the successfully polled channel of a FREEDM-84A672 device. The external controller must prepend an in-band channel address to each partial packet transfer across the transmit APPI to associate the data with a channel. In the receive direction, the FREEDM-84A672 performs channel assignment and packet extraction and validation. For each provisioned HDLC channel, the FREEDM-84A672 delineates the packet boundaries using flag sequence detection, and performs bit de-stuffing. Sharing of opening and closing flags, as well as sharing of zeros between flags are supported. The resulting packet data is placed into the internal 32 Kbyte partial packet buffer RAM. The partial packet buffer acts as a logical FIFO for each of the assigned channels. An external controller transfers partial packets out of the RAM, across the receive APPI bus, into host packet memory. The FREEDM-84A672 validates the frame check sequence for each packet, and verifies that the packet is an integral number of octets in length and is within a programmable minimum and maximum lengths. Receive APPI bus latency may cause one or more channels to overflow, in which case, the packets are aborted. The FREEDM-84A672 reports the status of each packet on the receive APPI at the end of each packet transfer.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
7
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Alternatively, in the receive direction, the FREEDM-84A672 supports a transparent operating mode. For each provisioned transparent channel, the FREEDM-84A672 directly transfers the received octets onto the receive APPI verbatim. If the transparent channel is assigned to a channelised link, then the octets are aligned to the received time-slots. In the transmit direction, an external controller provides packets to transmit using the transmit APPI. For each provisioned HDLC channel, an external controller transfers partial packets, across the transmit APPI, into the internal 32 Kbyte transmit partial packet buffer. The partial packets are read out of the partial packet buffer by the FREEDM-84A672 and a frame check sequence is optionally calculated and inserted at the end of each packet. Bit stuffing is performed before being assigned to a particular link. The flag or idle sequence is automatically inserted when there is no packet data for a particular channel. Sequential packets are optionally separated by a single flag (combined opening and closing flag) or up to 128 flags. Zeros between flags are not shared in the transmit direction although, as stated previously, they are accepted in the receive direction. Transmit APPI bus latency may cause one or more channels to underflow, in which case, the packets are aborted. The FREEDM-84A672 generates an interrupt to notify the host of aborted packets. For normal traffic, an abort sequence is generated, followed by inter-frame time fill characters (flags or all-ones bytes) until a new packet is sourced on the transmit APPI. The FREEDM-84A672 will not attempt to re-transmit aborted packets. Alternatively, in the transmit direction, the FREEDM-84A672 supports a transparent operating mode. For each provisioned transparent channel, the FREEDM-84A672 directly inserts the transmitted octets provided on the transmit APPI. If the transparent channel is assigned to a channelised link, then the octets are aligned to the transmitted time-slots. If a channel underflows due to excessive transmit APPI bus latency, an abort sequence is generated, followed by inter-frame time fill characters (flags or all-ones bytes) to indicate idle channel. Data resumes immediately when the FREEDM-84A672 receives new data on the transmit APPI. The FREEDM-84A672 is configured, controlled and monitored using the microprocessor interface. The FREEDM-84A672 is implemented in low power 2.5 Volt 0.25 mm CMOS technology. All FREEDM-84A672 I/O are 3.3 volt tolerant. The FREEDM-84A672 is packaged in a 352 pin enhanced ball grid array (SBGA) package.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
8
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
6
PIN DIAGRAM The FREEDM-84A672 is manufactured in a 352 pin enhanced ball grid array (SBGA) package.
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
A
VSS
VSS
N.C.
D[2]
D[6]
VDD2V5
D[12]
A[2]
A[5]
A[9]
ALE
CSB
VSS
VSS
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
VDD2V5
N.C.
N.C.
N.C.
VSS
VSS
A
B
TA[12]/ VSS VDD3V3 VSS TPA2[2] D[3] D[7] D[10] D[13] A[3] A[7] A[10] RDB N.C. VDD2V5 N.C. N.C. N.C. TRS TWRB N.C. TA[10] TA[8] TA[6] VSS VDD3V3 VSS
B
C
TPA2[1]
VSS
VDD3V3
N.C.
D[0]
D[4]
D[8]
D[11]
D[14]
A[4]
A[8]
WRB
INTB
N.C.
N.C.
N.C.
N.C.
N.C.
TRDB
N.C.
N.C.
N.C.
N.C.
VDD3V3
VSS
N.C.
C
D
TPA1[0] TPA2[0]
N.C.
VDD3V3
N.C.
D[1]
D[5]
D[9]
VDD3V3
D[15]
A[6]
A[11]
VDD3V3
N.C.
N.C.
N.C.
N.C.
VDD3V3
TA[11]
TA[9]
TA[7]
N.C.
VDD3V3
N.C.
TA[5]
N.C.
D
E
TXADDR [9]
TXADDR TPA1[2] [12] N.C. N.C. RSTB TA[4] N.C.
E
F
TXADDR [6]
TXADDR [8]
TXADDR TPA1[1] [11] N.C. N.C. TA[2] N.C.
F
G
TXADDR [3]
TXADDR VDD2V5 [5]
TXADDR TA[3] [10] N.C. TA[1] TA[0]
G
H
TXADDR TXCLK [2]
TXADDR [4]
TXADDR VDD2V5 [7] N.C. N.C. N.C.
H
J
TXDATA [13]
TXDATA [15]
TXADDR VDD3V3 [1] VDD3V3 N.C. N.C. N.C.
J
K
TXDATA [9]
TXDATA [11]
TXDATA [14]
TXADDR N.C. [0] N.C. N.C. N.C.
K
L
TXDATA N.C. [8]
TXDATA [10]
TXDATA N.C. [12] N.C. N.C. SYSCLK
L
M
TXDATA N.C. [7] TSX TXPRTY N.C. N.C. N.C. N.C.
M
N
TXDATA VSS VDD2V5 [5]
TXDATA [6]
BOTTOM VIEW
VDD3V3
N.C.
N.C.
VSS
N
P
TXDATA VSS [4]
TXDATA VDD3V3 [3] VDD2V5 RCLK[2] N.C. VSS
P
R
TXDATA [2]
TXDATA [1]
TXDATA TMOD [0] RD[0] RD[1] RCLK[1] RD[2]
R
T
TEOP
TERR
RVAL
RENB
N.C.
N.C.
N.C.
RCLK[0]
T
U
RXDATA TRDY RPA RMOD [15] TCK N.C. N.C. N.C.
U
V
RXDATA REOP RERR [14] VDD3V3 VDD3V3 TDI TRSTB N.C.
V
W
RXDATA RXPRTY [13]
RXDATA [11]
RXDATA SBI3_EN [9] N.C. TDO TMS
W
Y
RXDATA [12]
RXDATA [10]
RXDATA [8]
RXDATA TD[1] [6] VDD2V5 SBI1_EN FASTCLK
Y
AA
RXDATA VDD2V5 RSX [5]
RXDATA
C1FP_OUT
TCLK[1]
TD[0]
SBI2_EN
[2]
AA
AB
RXDATA [7]
RXDATA [4]
RXDATA N.C. [1] AV5 REFCLK TD[2] TCLK[0]
AB
AC
RXDATA [3]
RXDATA N.C. [0] VDD3V3 N.C.
RXADDR N.C. [1]
TDAT VDD3V3 [14]
TDAT N.C. [11] TDAT[7] N.C. VDD3V3
AJUST_REQ
ADATA [7]
DDATA VDD3V3 [4]
DDATA N.C. [1] DDP N.C. VDD3V3 N.C. APL TCLK[2]
AC
AD
RXADDR N.C. VSS VDD3V3 N.C. [2] N.C. N.C.
TDAT N.C. [13] N.C. N.C. TDAT[6] TDAT[4] TDAT[3]
ADETECT [0]
ADATA N.C. [6]
ADATA [4]
DDATA [2]
ADATA N.C. [1] ADP N.C. VDD3V3 VSS DPL
AD
AE
TDAT VSS VDD3V3 VSS RXCLK
PMCTEST
TDAT N.C. [12]
TDAT TDAT[8] [10] N.C. N.C. VDD2V5 N.C. TDAT[2] TDAT[0]
DDATA [7]
DDATA [5]
DDATA [3]
ADATA [2]
DDATA C1FP [0] DV5 VSS VDD3V3 VSS
[15]
AE
AF
RXADDR VSS VSS N.C. [0] N.C. VDD2V5 N.C. N.C. TDAT[9] N.C. N.C. TDAT[5] VSS VSS
ADETECT [1]
DDATA TDAT[1] N.C. [6]
ADATA [5]
ADATA VDD2V5 [3]
ADATA AACTIVE [0] N.C. VSS VSS
AF
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
9
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
7
PIN DESCRIPTION Table 1 - SBI Interface Signals (30) Pin Name REFCLK Type Input Pin No. AB3 Function The SBI reference clock signal (REFCLK) provides reference timing for the SBI ADD and DROP busses. REFCLK is nominally a 50% duty cycle clock of frequency 19.44 MHz 50ppm. FASTCLK Input Y1 The high-speed reference clock signal (FASTCLK) is used by the FREEDM-84A672 to generate an internal clock for use when processing DS-3 links. FASTCLK is nominally a 50% duty cycle, 50ppm clock having one of the following frequencies: 51.84 MHz, 44.928 MHz or 66 MHz. C1FP Input AE5 The C1 octet frame pulse signal (C1FP) provides frame synchronisation for devices connected via an SBI interface. C1FP must be asserted for 1 REFCLK cycle every 500 s or multiples thereof (i.e. every 9720 n REFCLK cycles, where n is a positive integer). All devices interconnected via an SBI interface must be synchronised to a C1FP signal from a single source. C1FP is sampled on the rising edge of REFCLK. Note - If the SBI bus is being operated in synchronous mode [Ref. 3], C1FP must be asserted for 1 REFCLK cycle every 6 ms or multiples thereof.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
10
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name C1FPOUT
Type Output
Pin No. AA4
Function The C1 octet frame pulse output signal (C1FPOUT) may be used to provide frame synchronisation for devices interconnected via an SBI interface. C1FPOUT is asserted for 1 REFCLK cycle every 500 s (i.e. every 9720 REFCLK cycles). If C1FPOUT is used for synchronisation, it must be connected to the C1FP inputs of all the devices connected to the SBI interface. C1FPOUT is updated on the rising edge of REFCLK. Note - The C1FPOUT pulse generated by FREEDM-84A672 is not suitable for use in systems in which the SBI bus is operated in synchronous mode [Ref. 3].
DDATA[0] DDATA[1] DDATA[2] DDATA[3] DDATA[4] DDATA[5] DDATA[6] DDATA[7]
Input
AE6 AC8 AD8 AE8 AC10 AE9 AF9 AE10
The SBI DROP bus data signals (DDATA[7:0]) contain the time division multiplexed receive data from the up to 84 independently timed links. Data from each link is transported as a tributary within the SBI TDM bus structure. Multiple PHY devices can drive the SBI DROP bus at uniquely assigned tributary column positions. DDATA[7:0] are sampled on the rising edge of REFCLK.
DDP
Input
AC6
The SBI DROP bus parity signal (DDP) carries the even or odd parity for the DROP bus signals. The parity calculation encompasses the DDATA[7:0], DPL and DV5 signals. Multiple PHY devices can drive DDP at uniquely assigned tributary column positions. This parity signal is intended to detect accidental PHY source clashes in the column assignment. DDP is sampled on the rising edge of REFCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
11
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name DPL
Type Input
Pin No. AD1
Function The SBI DROP bus payload signal (DPL) indicates valid data within the SBI TDM bus structure. This signal is asserted during all octets making up a tributary. This signal may be asserted during the V3 or H3 octet within a tributary to accommodate negative timing adjustments between the tributary rate and the fixed TDM bus structure. This signal may be deasserted during the octet following the V3 or H3 octet within a tributary to accommodate positive timing adjustments between the tributary rate and the fixed TDM bus structure. Multiple PHY devices can drive DPL at uniquely assigned tributary column positions. DPL is sampled on the rising edge of REFCLK.
DV5
Input
AE4
The SBI DROP bus payload indicator signal (DV5) locates the position of the floating payloads for each tributary within the SBI TDM bus structure. Timing differences between the port timing and the TDM bus timing are indicated by adjustments of this payload indicator relative to the fixed TDM bus structure. Multiple PHY devices can drive DV5 at uniquely assigned tributary column positions. All movements indicated by this signal must be accompanied by appropriate adjustments in the DPL signal. DV5 is sampled on the rising edge of REFCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
12
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name ADATA[0] ADATA[1] ADATA[2] ADATA[3] ADATA[4] ADATA[5] ADATA[6] ADATA[7]
Type Tristat e Output
Pin No. AF5 AD7 AE7 AF7 AD9 AF8 AD10 AC11
Function The SBI ADD bus data signals (ADATA[7:0]) contain the time division multiplexed transmit data from the up to 84 independently timed links. Data from each link is transported as a tributary within the SBI TDM bus structure. Multiple link layer devices can drive the SBI ADD bus at uniquely assigned tributary column positions. ADATA[7:0] are tristated when the FREEDM-84A672 is not outputting data on a particular tributary column. ADATA[7:0] are updated on the rising edge of REFCLK.
ADP
Tristat e Output
AD5
The SBI ADD bus parity signal (ADP) carries the even or odd parity for the ADD bus signals. The parity calculation encompasses the ADATA[7:0], APL and AV5 signals. Multiple link layer devices can drive this signal at uniquely assigned tributary column positions. ADP is tristated when the FREEDM-84A672 is not outputting data on a particular tributary column. This parity signal is intended to detect accidental link layer source clashes in the column assignment. ADP is updated on the rising edge of REFCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
13
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name APL
Type Tristat e Output
Pin No. AC2
Function The SBI ADD bus payload signal (APL) indicates valid data within the SBI TDM bus structure. This signal is asserted during all octets making up a tributary. This signal may be asserted during the V3 or H3 octet within a tributary to accommodate negative timing adjustments between the tributary rate and the fixed TDM bus structure. This signal may be deasserted during the octet following the V3 or H3 octet within a tributary to accommodate positive timing adjustments between the tributary rate and the fixed TDM bus structure. Multiple link layer devices can drive this signal at uniquely assigned tributary column positions. APL is tristated when the FREEDM-84A672 is not outputting data on a particular tributary column. APL is updated on the rising edge of REFCLK.
AV5
Tristat e output
AB4
The SBI ADD bus payload indicator signal (AV5) locates the position of the floating payloads for each tributary within the SBI TDM bus structure. Timing differences between the port timing and the TDM bus timing are indicated by adjustments of this payload indicator relative to the fixed TDM bus structure. Multiple link layer devices can drive this signal at uniquely assigned tributary column positions. AV5 is tristated when the FREEDM-84A672 is not outputting data on a particular tributary column. AV5 is updated on the rising edge of REFCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
14
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name AJUST_REQ
Type Input
Pin No. AC12
Function The SBI ADD bus justification request signal (AJUST_REQ) is used to speed up or slow down the output data rate of the FREEDM84A672. Negative timing adjustments are requested by asserting AJUST_REQ during the V3 or H3 octet, depending on the tributary type. In response to this the FREEDM-84A672 will send an extra byte in the V3 or H3 octet of the next frame along with a valid APL indicating a negative justification. Positive timing adjustments are requested by asserting AJUST_REQ during the octet following the V3 or H3 octet, depending on the tributary type. FREEDM-84A672 will respond to this by not sending an octet during the octet following the V3 or H3 octet of the next frame and deasserting APL to indicate a positive justification. AJUST_REQ is sampled on the rising edge of REFCLK.
AACTIVE
Output
AF4
The SBI ADD bus active indicator signal (AACTIVE) is asserted whenever FREEDM84A672 is driving the SBI ADD bus signals, ADATA[7:0], ADP, APL and AV5. All other Link Layer devices driving the SBI ADD bus should monitor this signal (to detect multiple sources accidentaly driving the bus) and should cease driving the bus whenever a conflict is detected. AACTIVE is updated on the rising edge of REFCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
15
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name ADETECT[0] ADETECT[1]
Type Input
Pin No. AD12 AF12
Function The SBI ADD bus conflict detection signals (ADETECT[1:0]) may be connected to the AACTIVE outputs of other link layer devices sharing the SBI ADD bus. FREEDM-84A672 will immediately tristate the SBI ADD bus signals ADATA[7:0], ADP, APL and AV5 if either of ADETECT[1] and ADETECT[0] is asserted. ADETECT[1:0] are asynchronous inputs.
Table 2 - Clock/Data Interface Signals (15) Pin Name RCLK[0] RCLK[1] RCLK[2] Type Input Pin No. T1 R2 P3 Function The receive line clock signals (RCLK[2:0]) contain the recovered line clock for the 3 independently timed links. RCLK[n] must be externally gapped during the bits or time-slots that are not part of the transmission format payload (i.e. not part of the HDLC packet). RCLK[2:0] is nominally a 50% duty cycle clock between 0 and 51.84 MHz. The RCLK[n] inputs are invalid and should be tied low when their associated link is not configured for operation (i.e. SPEn_EN input is high). RD[0] RD[1] RD[2] Input R4 R3 R1 The receive data signals (RD[2:0]) contain the recovered line data for the 3 independently timed links. RD[2:0] contain HDLC packet data. For certain transmission formats, RD[2:0] may contain place holder bits or timeslots. RCLK[n] must be externally gapped during the place holder positions in the RD[n] stream. The FREEDM-84A672 supports a maximum data rate of 51.84 Mbit/s on each link. RD[2:0] are sampled on the rising edge of the corresponding RCLK[2:0].
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
16
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name TCLK[0] TCLK[1] TCLK[2]
Type Input
Pin No. AB1 AA3 AC1
Function The transmit line clock signals (TCLK[2:0]) contain the transmit clocks for the 3 independently timed links. TCLK[n] must be externally gapped during the bits or time-slots that are not part of the transmission format payload (i.e. not part of the HDLC packet). TCLK[2:0] is nominally a 50% duty cycle clock between 0 and 51.84 MHz. The TCLK[n] inputs are invalid and should be tied low when their associated link is not configured for operation (i.e. SPEn_EN input is high).
TD[0] TD[1] TD[2]
Output
AA2 Y4 AB2
The transmit data signals (TD[2:0]) contain the transmit data for the 3 independently timed links. TD[2:0] contain HDLC packet data. For certain transmission formats, TD[2:0] may contain place holder bits or timeslots. TCLK[n] must be externally gapped during the place holder positions in the TD[n] stream. The FREEDM-84A672 supports a maximum data rate of 51.84 Mbit/s on each link. TD[2:0] are updated on the falling edge of the corresponding TCLK[2:0] clock.
SPE1_EN SPE2_EN SPE3_EN
Input
Y2 AA1 W4
The Synchronous Payload Envelope Enable signals (SPEn_EN) configure the operation of the clock/data inputs and the SBI Interface. When SPEn_EN is low, the corresponding Synchronous Payload Envelope conveyed on the SBI interface is unused and the corresponding independently timed link (signals RCLK[n-1], RD[n-1], TCLK[n-1] and TD[n-1]) is enabled. When SPEn_EN is high, the corresponding Synchronous Payload Envelope conveyed on the SBI interface is enabled and the corresponding independently timed link is disabled. SPEn_EN are asynchronous inputs.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
17
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 3 - Any-PHY Packet Interface Signals (70) Pin Name TXCLK Type Input Pin No. H26 Function The transmit clock signal (TXCLK) provides timing for the transmit Any-PHY packet interface. TXCLK is a nominally 50% duty cycle, 25 to 50 MHz clock. The transmit address signals (TXADDR[12:0]) provide a channel address for polling a transmit channel FIFO. The 10 least significant bits provide the channel number (0 to 671) while the 3 most significant bits select one of seven possible FREEDM-84A672 devices sharing a single external controller. (One address is reserved as a null address.) The Tx APPI of each FREEDM-84A672 device is identified by the base address in the TAPI672 Control register. The TXADDR[12:0] signals are sampled on the rising edge of TXCLK.
TXADDR[0] TXADDR[1] TXADDR[2] TXADDR[3] TXADDR[4] TXADDR[5] TXADDR[6] TXADDR[7] TXADDR[8] TXADDR[9] TXADDR[10] TXADDR[11] TXADDR[12]
Input
K23 J24 H25 G26 H24 G25 F26 H23 F25 E26 G23 F24 E25
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
18
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name TPA1[0] TPA1[1] TPA1[2] TPA2[0] TPA2[1] TPA2[2]
Type Tristate Output
Pin No. D26 F23 E24 D25 C26 B23
Function The transmit packet available signals (TPA1[2:0] and TPA2[2:0]) reflects the status of a poll of two transmit channel FIFOs. TPA1[2:0] returns the polled results for channel address `n' provided on TXADDR[12:0] and TPA2[2:0] returns the polled results for channel address `n+1'. TPAn[2] reports packet underrun events and TPAn[1:0] report the fill state of the transmit channel FIFO. TPAn[2] is set high when one or more packets has underrun on the channel and a further data transfer has occurred since it was last polled. When TPAn[2] is set low, no packet has underrun on the channel since the last poll. TPAn[1:0] are coded as follows: TPAn[1:0] = "11" TPAn[1:0] = "10" TPAn[1:0] = "01" TPAn[1:0] = "00" => => => => Starving (Reserved) Space Full
A "Starving" polled response indicates that the polled transmit channel FIFO is at risk of underflowing and should be supplied with data as soon as possible. A "Space" polled response indicates that the polled transmit channel FIFO can accept XFER[3:0] plus one blocks (16 bytes per block) of data. A "Full" polled response indicates that the polled transmit channel FIFO cannot accept XFER[3:0] plus one blocks of data. (XFER[3:0] is a per-channel programmable value - see description of register 0x38C.) It is the responsibility of the external controller to prevent channel underflow conditions by adequately polling each channel before data transfer. TPAn[2:0] are tristate during reset and when a device address other than the FREEDM84A672's base address is provided on TXADDR[12:10].
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
19
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name
Type
Pin No.
Function TPAn[2:0] are updated on the rising edge of TXCLK.
TRDY
Tristate Output
U26
The transmit ready signal (TRDY) indicates the ability of the transmit Any-PHY packet interface (APPI) to accept data. When TRDY is set low, the transmit APPI is unable to accept further data. When TRDY is set high, data provided on the transmit APPI will be accepted by the FREEDM-84A672 device. TRDY is asserted one TXCLK cycle after TSX is sampled high. TRDY is asserted by the FREEDM-84A672 device which was selected by the in-band channel address on TXDATA[15:0] when TSX was sampled high. If TRDY is driven low, the external controller must hold the data on TXDATA[15:0] until TRDY is driven high. TRDY may be driven low for 0 or more TXCLK cycles before it is driven high. TRDY is always driven tristate one TXCLK cycle after it is driven high. TRDY is tristate during reset. TRDY is updated on the rising edge of TXCLK. It is recommended that TRDY be connected externally to a weak pull-up, e.g. 10 kW.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
20
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name TXDATA[0] TXDATA[1] TXDATA[2] TXDATA[3] TXDATA[4] TXDATA[5] TXDATA[6] TXDATA[7] TXDATA[8] TXDATA[9] TXDATA[10] TXDATA[11] TXDATA[12] TXDATA[13] TXDATA[14] TXDATA[15]
Type Input
Pin No. R24 R25 R26 P24 P25 N24 N23 M26 L25 K26 L24 K25 L23 J26 K24 J25
Function The transmit data signals (TXDATA[15:0]) contain the transmit Any-PHY packet interface (APPI) data provided by the external controller. Data must be presented in big endian order, i.e. the byte in TXDATA[15:8] is transmitted by the FREEDM-84A672 before the byte in TXDATA[7:0]. The first word of each data transfer contains an address to identify the device and channel associated with the data being transferred. This prepended address must be qualified with the TSX signal. The 10 least significant bits provide the channel number (0 to 671) while the 3 most significant bits select one of seven possible FREEDM-84A672 devices sharing a single external controller. (One address is reserved as a null address.) The FREEDM-84A672 will not respond to channel addresses outside the range 0 to 671, nor to device addresses other than the base address stored in the TAPI672 Control register. The second and any subsequent words of each data transfer contain packet data. The TXDATA[15:0] signals are sampled on the rising edge of TXCLK.
TXPRTY
Input
M23
The transmit parity signal (TXPRTY) reflects the odd parity calculated over the TXDATA[15:0] signals. TXPRTY is only valid when TXDATA[15:0] are valid. TXPRTY is sampled on the rising edge of TXCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
21
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name TSX
Type Input
Pin No. M24
Function The transmit start of transfer signal (TSX) denotes the start of data transfer on the transmit APPI. When the TSX signal is sampled high, the sampled word on the TXDATA[15:0] signals contain the device and channel address associated with the data to follow. When the TSX signal is sampled low, the sampled word on the TXDATA[15:0] signals do not contain a device/channel address. The TSX signal is sampled on the rising edge of TXCLK.
TEOP
Input
T26
The transmit end of packet signal (TEOP) denotes the end of a packet. TEOP is only valid during data transfer. When TEOP is sampled high, the data on TXDATA[15:0] is the last word of a packet. When TEOP is sampled low, the data on TXDATA[15:0] is not the last word of a packet. TEOP is sampled on the rising edge of TXCLK. The transmit word modulo signal (TMOD) indicates the size of the current word on TXDATA[15:0]. TMOD is only valid when TEOP is sampled high. When TMOD is sampled high and TEOP is sampled high, only the TXDATA[15:8] signals contain valid data and the TXDATA[7:0] signals are invalid. When TMOD is sampled low and TEOP is sampled high, the complete word on TXDATA[15:0] contains valid data. TMOD must be set low when TEOP is set low. TMOD is sampled on the rising edge of TXCLK.
TMOD
Input
R23
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
22
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name TERR
Type Input
Pin No. T25
Function The transmit error signal (TERR) indicates that the current packet is errored and should be aborted. TERR is only valid when TEOP is sampled high. When TERR is sampled high and TEOP is sampled high, the current packet is errored and the FREEDM-84A672 will respond accordingly. When TERR is sampled low and TEOP is sampled high, the current packet is not errored. TERR must be set low when TEOP is set low. TERR is sampled on the rising edge of TXCLK. The receive clock signal (RXCLK) provides timing for the receive Any-PHY packet interface (APPI). RXCLK is a nominally 50% duty cycle, 25 to 50 MHz clock. The receive address signals (RXADDR[2:0]) serve two functions - device polling and device selection. When polling, the RXADDR[2:0] signals provide an address for polling a FREEDM-84A672 device for receive data available in any one of its 672 channels. Polling results are returned on the RPA tristate output. During selection, the address on the RXADDR[2:0] signals is qualified with the RENB signal to select a FREEDM-84A672 device enabling it to output data on the receive APPI. Note that up to seven FREEDM-84A672 devices may share a single external controller (one address is reserved as a null address). The Rx APPI of each FREEDM-84A672 device is identified by the base address in the RAPI672 Control register. The RXADDR[2:0] signals are sampled on the rising edge of RXCLK.
RXCLK
Input
AE23
RXADDR[0] RXADDR[1] RXADDR[2]
Input
AF23 AC21 AD22
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
23
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name RPA
Type Tristate Output
Pin No. U25
Function The receive packet available signal (RPA) reflects the status of a poll on the receive APPI of a FREEDM-84A672 device. When RPA is set high, the polled FREEDM-84A672 device has XFER[3:0] plus one blocks (16 bytes per block) of data to transfer, or alternatively, a smaller amount of data which includes an end of packet. When RPA is set low, the polled FREEDM84A672 device does not have data ready to transfer. (XFER[3:0] is a per-channel programmable value - see description of register 0x208.) A FREEDM-84A672 device must not be selected for receive data transfer unless it has been polled and responded that it has data ready to transfer. When the RXADDR[2:0] inputs match the base address in the RAPI672 Control register, that FREEDM-84A672 device drives RPA one RXCLK cycle after sampling RXADDR[2:0]. RPA is tristate during reset and when a device address other than the FREEDM-84A672's base address is provided on RXADDR[2:0]. RPA is updated on the rising edge of RXCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
24
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name RENB
Type Input
Pin No. T23
Function The receive enable signal (RENB) qualifies the RXADDR[2:0] signals for selection of a FREEDM-84A672 device. When RENB is sampled high and then low in consecutive RXCLK cycles, the address on RXADDR[2:0] during the cycle when RENB is sampled high selects a FREEDM-84A672 device enabling it to output data on the receive APPI. The Rx APPI of each FREEDM-84A672 device is identified by the base address in the RAPI672 Control register. The polling function of the RXADDR[2:0] and RPA signals operates regardless of the state of RENB. RENB may also be used to throttle the FREEDM-84A672 during data transfer on the Rx APPI. When the FREEDM-84A672 samples RENB high during data transfer, the FREEDM84A672 will pause the data transfer and tri-state the receive APPI outputs (except RPA) until RENB is returned low. Since the Any-PHY bus specification does not support deselection during data transfers, the address on the RXADDR[2:0] inputs during the cycle before RENB is returned low must either re-select the same FREEDM-84A672 device or be a null address. To commence data transfer, RENB must be sampled low following device selection. It is the responsibility of the external controller to prevent overflow by providing each FREEDM84A672 device on an Any-PHY point to multipoint bus sufficient bandwidth through selection. RENB is sampled on the rising edge of RXCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
25
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name RXDATA[0] RXDATA[1] RXDATA[2] RXDATA[3] RXDATA[4] RXDATA[5] RXDATA[6] RXDATA[7] RXDATA[8] RXDATA[9] RXDATA[10] RXDATA[11] RXDATA[12] RXDATA[13] RXDATA[14] RXDATA[15]
Type Tristate Output
Pin No. AC25 AB24 AA23 AC26 AB25 AA24 Y23 AB26 Y24 W23 Y25 W24 Y26 W25 V24 U23
Function The receive data signals (RXDATA[15:0]) contain the receive Any-PHY packet interface (APPI) data output by the FREEDM-84A672 when selected. Data is presented in big endian format, i.e. the byte in RXDATA[15:8] was received by the FREEDM-84A672 before the byte in RXDATA[7:0]. The first word of each data transfer (when RSX is high) contains an address to identify the device and channel associated with the data being transferred. The 10 least significant bits (RXDATA[9:0]) contain the channel number (0 to 671) and the 3 most significant bits (RXDATA[15:13]) contain the device base address. The second and any subsequent words of each data transfer contain valid data. The FREEDM-84A672 may be programmed to overwrite RXDATA[7:0] of the final word of each packet transfer (REOP is high) with the status of packet reception when that packet is errored (RERR is high). This status information is bit mapped as follows: RXDATA[0]='1' => channel FIFO overrun. RXDATA[1]='1' => max. packet length violation. RXDATA[2]='1' => FCS error. RXDATA[3]='1' => non-octet aligned. RXDATA[4]='1' => HDLC packet abort. RXDATA[7:5]="Xh" => Reserved. The RXDATA[15:0] signals are tristated when the FREEDM-84A672 device is not selected via the RENB signal. The RXDATA[15:0] signals are updated on the rising edge of RXCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
26
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name RXPRTY
Type Tristate Output
Pin No. W26
Function The receive parity signal (RXPRTY) reflects the odd parity calculated over the RXDATA[15:0] signals. RXPRTY is driven/tristated at the same time as RXDATA[15:0]. RXPRTY is updated on the rising edge of RXCLK.
RSX
Tristate Output
AA25
The receive start of transfer signal (RSX) denotes the start of data transfer on the receive APPI. When the RSX signal is set high, the 3 most significant bits on the RXDATA[15:0] signals contain the FREEDM-84A672 device address and the 10 least significant bits on the RXDATA[15:0] signals contain the channel address associated with the data to follow. Valid device addresses are in the range 0 through 7 (with one address reserved as a null address) and valid channel addresses are in the range 0 through 671. When the RSX signal is sampled low, the word on the RXDATA[15:0] signals does not contain a device and channel address. RSX is tristated when the FREEDM-84A672 device is not selected via the RENB signal. RSX is updated on the rising edge of RXCLK. It is recommended that RSX be connected externally to a weak pull-down, e.g. 10 kW.
REOP
Tristate Output
V26
The receive end of packet signal (REOP) denotes the end of a packet. REOP is only valid during data transfer. When REOP is set high, RXDATA[15:0] contains the last data byte of a packet. When REOP is set low, RXDATA[15:0] does not contain the last data byte of a packet. REOP is tristated when the FREEDM-84A672 device is not selected via the RENB signal. REOP is updated on the rising edge of RXCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
27
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name RMOD
Type Tristate Output
Pin No. U24
Function The receive word modulo signal (RMOD) indicates the size of the current word on RXDATA[15:0]. When RDAT[15:0] does not contain the last byte of a packet (REOP set low), RMOD is set low. When RMOD is set high and REOP is set high, RXDATA[15:8] contains the last data byte of a packet. When RMOD is set low and REOP is set high, RXDATA[7:0] contains the last byte of the packet, or optionally, the error status byte. The behavior of RMOD relates only to packet data and is unaffected when the FREEDM-84A672 device is programmed to overwrite RXDATA[7:0] with status information when errored packets are received. RMOD is tristated when the FREEDM-84A672 device is not selected via the RENB signal. RMOD is updated on the rising edge of RXCLK.
RERR
Tristate Output
V25
The receive error signal (RERR) indicates that the current packet is errored and should be discarded. When RDAT[15:0] does not contain the last byte of a packet (REOP set low), RERR is set low. When RERR is set high and REOP is set high, the current packet is errored. When RERR is set low and REOP is set high, the current packet is not errored. The FREEDM-84A672 may be programmed to overwrite RXDATA[7:0] of the final word of each packet transfer (REOP set high) with the status of packet reception when that packet is errored (RERR is high). RERR is tristated when the FREEDM-84A672 device is not selected via the RENB signal. RERR is updated on the rising edge of RXCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
28
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name RVAL
Type Tristate Output
Pin No. T24
Function The receive data valid (RVAL) is asserted when packet data is being output on RXDATA[15:0]. It is deasserted whenever the FREEDM-84A672 device is selected, but not outputting packet data on RXDATA[15:0]. (E.g., when RSX is high and address/channel prepend is being output on RXDATA[15:0], RVAL is deasserted.) RVAL is tristated when the FREEDM-84A672 device is not selected via the RENB signal. RVAL is updated on the rising edge of RXCLK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
29
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 4 - Microprocessor Interface Signals (31) Pin Name D[0] D[1] D[2] D[3] D[4] D[5] D[6] D[7] D[8] D[9] D[10] D[11] D[12] D[13] D[14] D[15] A[2] A[3] A[4] A[5] A[6] A[7] A[8] A[9] A[10] A[11] ALE Type I/O Pin No. C22 D21 A23 B22 C21 D20 A22 B21 C20 D19 B20 C19 A20 B19 C18 D17 A19 B18 C17 A18 D16 B17 C16 A17 B16 D15 A16 Function The bi-directional data signals (D[15:0]) provide a data bus to allow the FREEDM-84A672 device to interface to an external micro-processor. Both read and write transactions are supported. The microprocessor interface is used to configure and monitor the FREEDM-84A672 device.
Input
The address signals (A[11:2]) provide an address bus to allow the FREEDM-84A672 device to interface to an external microprocessor. All microprocessor accessible registers are dword aligned.
Input
The address latch enable signal (ALE) latches the A[11:2] signals during the address phase of a bus transaction. When ALE is set high, the address latches are transparent. When ALE is set low, the address latches hold the address provided on A[11:2]. ALE has an integral pull-up resistor.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
30
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name WRB
Type Input
Pin No. C15
Function The write strobe signal (WRB) qualifies write accesses to the FREEDM-84A672 device. When CSB is set low, the D[15:0] bus contents are clocked into the addressed register on the rising edge of WRB. The read strobe signal (RDB) qualifies read accesses to the FREEDM-84A672 device. When CSB is set low, the FREEDM-84A672 device drives the D[15:0] bus with the contents of the addressed register on the falling edge of RDB. The chip select signal (CSB) qualifies read/write accesses to the FREEDM-84A672 device. The CSB signal must be set low during read and write accesses. When CSB is set high, the microprocessor interface signals are ignored by the FREEDM-84A672 device. If CSB is not required (register accesses controlled only by WRB and RDB) then CSB should be connected to an inverted version of the RSTB signal.
RDB
Input
B15
CSB
Input
A15
INTB
OpenDrain Output
C14
The interrupt signal (INTB) indicates that an interrupt source is active and unmasked. When INTB is set low, the FREEDM-84A672 device has an active interrupt that is unmasked. When INTB is tristate, no interrupts are active, or an active interrupt is masked. Please refer to the register description section of this document for possible interrupt sources and masking. It is the responsibility of the external microprocessor to read the status registers in the FREEDM-84A672 device to determine the exact cause of the interrupt. INTB is an open drain output.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
31
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 5 - Miscellaneous Interface Signals (111) Pin Name SYSCLK Type Input Pin No. L1 Function The system clock (SYSCLK) provides timing for the core logic. SYSCLK is nominally a 50% duty cycle clock of frequency 45 MHz 50ppm. The active low reset signal (RSTB) signal provides an asynchronous FREEDM-84A672 reset. RSTB is an asynchronous input. When RSTB is set low, all FREEDM-84A672 registers are forced to their default states. In addition, all SBI, APPI and P interface output pins are forced tristate and will remain tristated until RSTB is set high.
RSTB
Input
E3
PMCTEST
Input
AE22 The PMC production test enable signal (PMCTEST) places the FREEDM-84A672 is test mode. When PMCTEST is set high, production test vectors can be executed to verify manufacturing via the test mode interface signals TA[11:0], TA[12]/TRS, TRDB, TWRB and TDAT[15:0]. PMCTEST must be tied low for normal operation. U4 The test clock signal (TCK) provides timing for test operations that can be carried out using the IEEE P1149.1 test access port. TMS and TDI are sampled on the rising edge of TCK. TDO is updated on the falling edge of TCK. The test mode select signal (TMS) controls the test operations that can be carried out using the IEEE P1149.1 test access port. TMS is sampled on the rising edge of TCK. TMS has an integral pull up resistor. The test data input signal (TDI) carries test data into the FREEDM-84A672 via the IEEE P1149.1 test access port. TDI is sampled on the rising edge of TCK. TDI has an integral pull up resistor.
TCK
Input
TMS
Input
W1
TDI
Input
V3
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
32
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name TDO
Type
Pin No.
Function The test data output signal (TDO) carries test data out of the FREEDM-84A672 via the IEEE P1149.1 test access port. TDO is updated on the falling edge of TCK. TDO is a tristate output which is inactive except when scanning of data is in progress. The active low test reset signal (TRSTB) provides an asynchronous FREEDM-84A672 test access port reset via the IEEE P1149.1 test access port. TRSTB is an asynchronous input with an integral pull up resistor. Note that when TRSTB is not being used, it must be connected to the RSTB input.
Tristate W2 Output
TRSTB
Input
V2
NC1-103
Open
These pins must be left unconnected.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
33
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 6 - Production Test Interface Signals (31) Pin Name TA[0] TA[1] TA[2] TA[3] TA[4] TA[5] TA[6] TA[7] TA[8] TA[9] TA[10] TA[11] TA[12]/TR S Type Input Pin No. G1 G2 F2 G4 E2 D2 B4 D6 B5 D7 B6 D8 B9 Function The test mode address bus (TA[11:0]) selects specific registers during production test (PMCTEST set high) read and write accesses. In normal operation (PMCTEST set low), these signals should be grounded.
Input
The test register select signal (TA[12]/TRS) selects between normal and test mode register accesses during production test (PMCTEST set high). TRS is set high to select test registers and is set low to select normal registers. In normal operation (PMCTEST set low), this signal should be grounded. The test mode read enable signal (TRDB) is set low during FREEDM-84A672 register read accesses during production test (PMCTEST set high). The FREEDM-84A672 drives the test data bus (TDAT[15:0]) with the contents of the addressed register while TRDB is low. In normal operation (PMCTEST set low), this signal should be tied to logic 1. The test mode write enable signal (TWRB) is set low during FREEDM-84A672 register write accesses during production test (PMCTEST set high). The contents of the test data bus (TDAT[15:0]) are clocked into the addressed register on the rising edge of TWRB. In normal operation (PMCTEST set low), this signal should be tied to logic 1.
TRDB
Input
C8
TWRB
Input
B8
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
34
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name TDAT[0] TDAT[1] TDAT[2] TDAT[3] TDAT[4] TDAT[5] TDAT[6] TDAT[7] TDAT[8] TDAT[9] TDAT[10] TDAT[11] TDAT[12] TDAT[13] TDAT[14] TDAT[15]
Type I/O
Pin No. AE11 AF11 AE12 AD13 AD14 AF15 AD15 AC15 AE17 AF18 AE18 AC17 AE19 AD19 AC19 AE21
Function The bi-directional test mode data bus (TDAT[15:0]) carries data read from or written to FREEDM-84A672 registers during production test (PMCTEST set high). In normal operation (PMCTEST set low), these signals should be left unconnected.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
35
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 7 - Power and Ground Signals (64) Pin Name VDD3V3[1] VDD3V3[2] VDD3V3[3] VDD3V3[4] VDD3V3[5] VDD3V3[6] VDD3V3[7] VDD3V3[8] VDD3V3[9] VDD3V3[10] VDD3V3[11] VDD3V3[12] VDD3V3[13] VDD3V3[14] VDD3V3[15] VDD3V3[16] VDD3V3[17] VDD3V3[18] VDD3V3[19] VDD3V3[20] VDD3V3[21] VDD3V3[22] VDD3V3[23] VDD3V3[24] VDD2V5[1] VDD2V5[2] VDD2V5[3] VDD2V5[4] VDD2V5[5] VDD2V5[6] VDD2V5[7] VDD2V5[8] VDD2V5[9] VDD2V5[10] VDD2V5[11] VDD2V5[12] Type Power Pin No. B25 C3 C24 D4 D9 D14 D18 D23 J4 N4 P23 J23 V4 V23 AC4 AC9 AC13 AC18 AC23 AD3 AE2 AE25 B2 AD24 H4 P4 Y3 AF6 AE14 AF21 AA26 N25 G24 A21 B13 A6 Function The VDD3V3[24:1] DC power pins should be connected to a well decoupled +3.3 V DC supply. These power pins provide DC current to the I/O pads.
Power
The VDD2V5[12:1] DC power pins should be connected to a well decoupled +2.5 V DC supply. These power pins provide DC current to the digital core.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
36
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin Name VSS[1] VSS[2] VSS[3] VSS[4] VSS[5] VSS[6] VSS[7] VSS[8] VSS[9] VSS[10] VSS[11] VSS[12] VSS[13] VSS[14] VSS[15] VSS[16] VSS[17] VSS[18] VSS[19] VSS[20] VSS[21] VSS[22] VSS[23] VSS[24] VSS[25] VSS[26] VSS[27] VSS[28]
Type Ground
Pin No. A1 A2 A13 A14 A25 A26 B1 B3 B24 B26 C2 C25 N1 N26 P1 P26 AD2 AD25 AE1 AE3 AE24 AE26 AF1 AF2 AF13 AF14 AF25 AF26
Function The VSS[28:1] DC ground pins should be connected to ground. They provide a ground reference for the 3.3 V rail. They also provide a ground reference for the 2.5 V rail.
Notes on Pin Description: 1. All FREEDM-84A672 inputs and bi-directionals present minimum capacitive loading and are 3.3V tolerant. 2. All FREEDM-84A672 outputs and bi-directionals have 8 mA drive capability except TDO, which has 4 mA drive capability. 3. All FREEDM-84A672 outputs can be tristated under control of the IEEE P1149.1 test access port, even those which do not tristate under normal operation. All outputs and bi-directionals are 3.3 V tolerant when tristated.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
37
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
4. All inputs with the exception of the Any-PHY interface are Schmitt triggered. Inputs ALE, TMS, TDI and TRSTB have internal pull-up resistors. 5. Power to the VDD3V3 pins should be applied before power to the VDD2V5 pins is applied. Similarly, power to the VDD2V5 pins should be removed before power to the VDD3V3 pins is removed.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
38
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
8 8.1
FUNCTIONAL DESCRIPTION Scaleable Bandwidth Interconnect (SBI) Interface The Scaleable Bandwidth Interconnect is a synchronous, time-division multiplexed bus designed to transfer, in a pin-efficient manner, data belonging to a number of independently timed links of varying bandwidth. The bus is timed to a reference 19.44MHz clock and a 2 kHz or 166.7Hz frame pulse. All sources and sinks of data on the bus are timed to the reference clock and frame pulse. Timing is communicated across the Scaleable Bandwidth Interconnect by floating data structures. Payload indicator signals in the SBI control the position of the floating data structure and therefore the timing. When sources are running faster than the SBI the floating payload structure is advanced by an octet by passing an extra octet in the V3 octet locations (H3 octet for DS3 mappings). When the source is slower than the SBI the floating payload is retarded by leaving the octet after the V3 or H3 octet unused. Both these rate adjustments are indicated by the SBI control signals. An SBI interface consists of a DROP BUS and an ADD BUS. On the DROP BUS all timing is sourced from the PHY and is passed onto the FREEDM-84A672 by the arrival rate of data over the SBI. On the ADD BUS timing can be controlled by either the PHY or the FREEDM-84A672. When the FREEDM-84A672 is the timing master, the PHY device determines its transmit timing information from the arrival rate of data across the SBI. When the PHY device is the timing master, it signals the FREEDM-84A672 to speed up or slow down with justification request signals. The PHY timing master indicates a speedup request to the Link Layer by asserting the justification request signal high during the V3 or H3 octet. When this is detected by the FREEDM-84A672 it will advance the channel by inserting data in the next V3 or H3 octet as described above. The PHY timing master indicates a slowdown request to the FREEDM-84A672 by asserting the justification request signal high during the octet after the V3 or H3 octet. The FREEDM-84A672 responds by leaving the octet following the next V3 or H3 octet unused. Both advance and retard rate adjustments take place in the frame or multi-frame following the justification request. The SBI multiplexing structure is modeled on the SONET/SDH standards. The SONET/SDH virtual tributary structure is used to carry T1/J1 and E1 links. Unchannelized DS3 payloads follow a byte synchronous structure modeled on the SONET/SDH format. The SBI structure uses a locked SONET/SDH structure fixing the position of the TUG-3/TU-3 relative to the STS-3/STM-1 transport frame. The SBI is also of fixed
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
39
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
frequency and alignment as determined by the reference clock (REFCLK) and frame indicator signal (C1FP). Frequency deviations are compensated by adjusting the location of the T1/J1/E1/DS3 channels using floating tributaries as determined by the V5 indicator and payload signals (DV5, AV5, DPL and APL). The multiplexed links are separated into three Synchronous Payload Envelopes. Each envelope may be configured independently to carry up to 28 T1/J1s, 21 E1s or a DS3. 8.2 High-Level Data Link Control (HDLC) Protocol Figure 1 shows a diagram of the synchronous HDLC protocol supported by the FREEDM-84A672 device. The incoming stream is examined for flag bytes (01111110 bit pattern) which delineate the opening and closing of the HDLC packet. The packet is bit de-stuffed which discards a "0" bit which directly follows five contiguous "1" bits. The resulting HDLC packet size must be a multiple of an octet (8 bits) and within the expected minimum and maximum packet length limits. The minimum packet length is that of a packet containing two information bytes (address and control) and FCS bytes. For packets with CRC-CCITT as FCS, the minimum packet length is four bytes while those with CRC-32 as FCS, the minimum length is six bytes. An HDLC packet is aborted when seven contiguous "1" bits (with no inserted "0" bits) are received. At least one flag byte must exist between HDLC packets for delineation. Contiguous flag bytes, or all ones bytes between packets are used as an "inter-frame time fill". Adjacent flag bytes may share zeros. Figure 1 - HDLC Frame
Flag Information HDLC Packet FCS Flag Flag
The CRC algorithm for the frame checking sequence (FCS) field is either a CRC-CCITT or CRC-32 function. Figure 2 shows a CRC encoder block diagram using the generating polynomial g(X) = 1 + g1X + g2X2 +...+ gn-1Xn-1 + Xn. The CRC-CCITT FCS is two bytes in size and has a generating polynomial g(X) = 1 + X5 + X12 + X16. The CRC-32 FCS is four bytes in size and has a generating polynomial g(X) = 1 + X + X2 + X4 + X5 + X7 + X8 + X10 + X11 + X12 + X16 + X22 + X23 + X26 + X32. The first FCS bit received is the residue of the highest term.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
40
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 2 - CRC Generator
g1
g2
gn-1 Message
D0
D1
D2
Dn-1
LSB
Parity Check Digits
MSB
8.3
SBI Extracter and PISO The SBI receive circuitry consists of an SBI Extract block and three SBI Parallel to Serial Converter (SBI PISO) blocks. The SBI Extract block receives data from the SBI DROP BUS and converts it to an internal parallel bus format. The received data is then converted to serial bit streams by the PISO blocks. Each PISO block processes one of the three Synchronous Payload Envelopes (SPEs) conveyed on the SBI DROP BUS. The SBI Extract block may be configured to enable or disable reception of individual tributaries within the SBI DROP bus. Individual tributaries may also be configured to operate in framed or unframed mode. Each PISO block processes data from one SPE on the internal parallel bus and generates either 28 serial data streams at T1/J1 rate, 21 streams at E1 rate or a single stream at DS-3 rate. These serial streams are then processed by the Receive Channel Assigner block.
8.4
Receive Channel Assigner The Receive Channel Assigner block (RCAS672) processes up to 84 serial links. When receiving data from the SBI PISO blocks, links may be configured to support channelised T1/J1/E1 traffic, unchannelised DS-3 traffic or unframed traffic at T1/J1, E1 or DS-3 rates. When receiving data from the RCLK/RD inputs, links 0, 1 and 2 support unchannelised data at arbitary rates up to 51.84 Mbps. Each link is independent and has its own associated clock. For each link, the RCAS672 performs a serial to parallel conversion to form data bytes. The data bytes are multiplexed, in byte serial format, for delivery to the Receive HDLC Processor / Partial Packet Buffer block (RHDL672) at SYSCLK rate. In the event
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
41
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
where multiple streams have accumulated a byte of data, multiplexing is performed on a fixed priority basis with link #0 having the highest priority and link #83 the lowest. The 84 RCAS links have a fixed relationship to the SPE and tributary numbers on the SBI DROP BUS as shown in the following table. Table 8 - SBI SPE/Tributary to RCAS Link Mapping SBI SPE No. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SBI Trib. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 RCAS Link No. 0 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51 54 57 60 63 SBI SPE No. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 SBI Trib. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 RCAS Link No. 1 4 7 10 13 16 19 22 25 28 31 34 37 40 43 46 49 52 55 58 61 64 SBI SPE No. 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 SBI Trib. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 RCAS Link No. 2 5 8 11 14 17 20 23 26 29 32 35 38 41 44 47 50 53 56 59 62 65
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
42
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
SBI SPE No. 1 1 1 1 1 1
SBI Trib. No. 23 24 25 26 27 28
RCAS Link No. 66 69 72 75 78 81
SBI SPE No. 2 2 2 2 2 2
SBI Trib. No. 23 24 25 26 27 28
RCAS Link No. 67 70 73 76 79 82
SBI SPE No. 3 3 3 3 3 3
SBI Trib. No. 23 24 25 26 27 28
RCAS Link No. 68 71 74 77 80 83
Links containing a T1/J1 or an E1 stream may be channelised. Data at each time-slot may be independently assigned to a different channel. The RCAS672 performs a table lookup to associate the link and time-slot identity with a channel. The position of T1/J1 and E1 framing bits/bytes is identified by frame pulse signals generated by the SBI PISO blocks. Links containing a DS-3 stream are unchannelised, i.e. all data on the link belongs to one channel. The RCAS672 performs a table lookup using only the link number to determine the associated channel, as time-slots are non-existent in unchannelised links. Links may additionally be configured to operate in an unframed "clear channel" mode, in which all bit positions, including those normally reserved for framing information, are assumed to be carrying HDLC data. Links so configured operate as unchannelised regardless of link rate and the RCAS672 performs a table lookup using only the link number to determine the associated channel. 8.4.1 Line Interface There are 84 line interface blocks in the RCAS672. Each line interface block contains a bit counter, an 8-bit shift register and a holding register that, together, perform serial to parallel conversion. Whenever the holding register is updated, a request for service is sent to the priority encoder block. When acknowledged by the priority encoder, the line interface responds with the data residing in the holding register. To support channelised links, each line interface block contains a time-slot counter. The time-slot counter is incremented each time the holding register is updated and is reset on detection of a frame pulse from the SBI PISO blocks. For unchannelised or unframed links, the time-slot counter is held reset.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
43
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
8.4.2 Priority Encoder The priority encoder monitors the line interfaces for requests and synchronises them to the SYSCLK timing domain. Requests are serviced on a fixed priority scheme where highest to lowest priority is assigned from the line interface attached to link 0 to that attached to link 83. Thus, simultaneous requests from link `m' will be serviced ahead of link `n', if m < n. When there are no pending requests, the priority encoder generates an idle cycle. In addition, once every fourth SYSCLK cycle, the priority encoder inserts a null cycle where no requests are serviced. This cycle is used by the channel assigner downstream for host microprocessor accesses to the provisioning RAMs. 8.4.3 Channel Assigner The channel assigner block determines the channel number of the data byte currently being processed. The block contains a 2688 word channel provision RAM. The address of the RAM is constructed from concatenating the link number and the time-slot number of the current data byte. The fields of each RAM word include the channel number and a time-slot enable flag. The time-slot enable flag labels the current time-slot as belonging to the channel indicated by the channel number field. 8.4.4 Loopback Controller The loopback controller block implements the channel based diagnostic loopback function. Every valid data byte belonging to a channel with diagnostic loopback enabled from the Transmit HDLC Processor / Partial Packet Buffer block (THDL672) is written into a 256 word FIFO. The loopback controller monitors for an idle time-slot or a time-slot carrying a channel with diagnostic loopback enabled. If either conditions hold, the current data byte is replaced by data retrieved from the loopback data FIFO. 8.5 Receive HDLC Processor / Partial Packet Buffer The Receive HDLC Processor / Partial Packet Buffer block (RHDL672) processes up to 672 synchronous transmission HDLC data streams. Each channel can be individually configured to perform flag sequence detection, bit destuffing and CRC-CCITT or CRC-32 verification. The packet data is written into the partial packet buffer. At the end of a frame, packet status including CRC error, octet alignment error and maximum length violation are also loaded into the partial packet buffer. Alternatively, a channel can be provisioned as transparent, in which case, the HDLC data stream is passed to the partial packet buffer processor verbatim.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
44
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
There is a natural precedence in the alarms detectable on a receive packet. Once a packet exceeds the programmable maximum packet length, no further processing is performed on it. Thus, octet alignment detection, FCS verification and abort recognition are squelched on packets with a maximum length violation. An abort indication squelches octet alignment detection, minimum packet length violations, and FCS verification. In addition, FCS verification is only performed on packets that do not have octet alignment errors, in order to allow the RHDL672 to perform CRC calculations on a byte-basis. The partial packet buffer is a 32 Kbyte RAM that is divided into 16-byte blocks. Each block has an associated pointer which points to another block. A logical FIFO is created for each provisioned channel by programming the block pointers to form a circular linked list. A channel FIFO can be assigned a minimum of 3 blocks (48 bytes) and a maximum of 2048 blocks (32 Kbytes). The depth of the channel FIFOs are monitored in a round-robin fashion. Requests are made to the Receive Any-PHY Interface block (RAPI672) to transfer, on the Rx APPI, data in channel FIFOs with depths exceeding their associated threshold. 8.5.1 HDLC Processor The HDLC processor is a time-slice state machine which can process up to 672 independent channels. The state vector and provisioning information for each channel is stored in a RAM. Whenever new channel data arrives, the appropriate state vector is read from the RAM, processed and written back to the RAM. The HDLC state-machine can be configured to perform flag delineation, bit de-stuffing, CRC verification and length monitoring. The resulting HDLC data and status information is passed to the partial packet buffer processor to be stored in the appropriate channel FIFO buffer. The configuration of the HDLC processor is accessed using indirect channel read and write operations. When an indirect operation is performed, the information is accessed from RAM during a null clock cycle generated by the upstream Receive Channel Assigner block (RCAS672). Writing new provisioning data to a channel resets the channel's entire state vector. 8.5.2 Partial Packet Buffer Processor The partial packet buffer processor controls the 32 Kbyte partial packet RAM which is divided into 16 byte blocks. A block pointer RAM is used to chain the partial packet blocks into circular channel FIFO buffers. Thus, non-contiguous sections of the RAM can be allocated in the partial packet buffer RAM to create a channel FIFO. System software is responsible for the assignment of blocks to individual channel FIFOs. Figure 3 shows an example of three blocks (blocks 1, 3, and 200) linked together to form a 48 byte channel FIFO.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
45
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 3 - Partial Packet Buffer Structure
Partial Packet Buffer RAM
Block 0 Block 1 Block 2 Block 3 16 bytes 16 bytes 16 bytes 16 bytes Block 0 Block 1 Block 2 Block 3
Block Pointer RAM
XX 0x03 XX 0xC8
Block 200
16 bytes
Block 200
0x01
Block 2047
16 bytes
Block 2047
XX
The partial packet buffer processor is divided into three sections: writer, reader and roamer. The writer is a time-sliced state machine which writes the HDLC data and status information from the HDLC processor into a channel FIFO in the packet buffer RAM. The reader transfers channel FIFO data from the packet buffer RAM to the downstream Receive Any-PHY Interface block (RAPI672). The roamer is a time-sliced state machine which tracks channel FIFO buffer depths and signals the reader to service a particular channel. If a buffer over-run occurs, the writer ends the current packet from the HDLC processor in the channel FIFO with an overrun flag and ignores the rest of the packet. The FIFO algorithm of the partial packet buffer processor is based on a programmable per-channel transfer size. Instead of tracking the number of full blocks in a channel FIFO, the processor tracks the number of transactions. Whenever the partial packet writer fills a transfer-sized number of blocks or writes an end-of-packet flag to the channel FIFO, a transaction is created. Whenever the partial packet reader transmits a transfer-size number of blocks or an end-ofpacket flag to the RAPI672 block, a transaction is deleted. Thus, small packets
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
46
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
less than the transfer size will be naturally transferred to the RAPI672 block without having to precisely track the number of full blocks in the channel FIFO. The partial packet roamer performs the transaction accounting for all channel FIFOs. The roamer increments the transaction count when the writer signals a new transaction and sets a per-channel flag to indicate a non-zero transaction count. The roamer searches the flags in a round-robin fashion to decide for which channel FIFO to request transfer by the RAPI672 block. The roamer informs the partial packet reader of the channel to process. The reader transfers the data to the RAPI672 until the channel transfer size is reached or an end of packet is detected. The reader then informs the roamer that a transaction is consumed. The roamer updates its transaction count and clears the non-zero transaction count flag if required. The roamer then services the next channel with its transaction flag set high. The writer and reader determine empty and full FIFO conditions using flags. Each block in the partial packet buffer has an associated flag. The writer sets the flag after the block is written and the reader clears the flag after the block is read. The flags are initialized (cleared) when the block pointers are written using indirect block writes. The writer declares a channel FIFO overrun whenever the writer tries to store data to a block with a set flag. In order to support optional removal of the FCS from the packet data, the writer does not declare a block as filled (set the block flag nor increment the transaction count) until the first double word of the next block in channel FIFO is filled. If the end of a packet resides in the first double word, the writer declares both blocks as full at the same time. When the reader finishes processing a transaction, it examines the first double word of the next block for the end-of-packet flag. If the first double word of the next block contains only FCS bytes, the reader would, optionally, process next transaction (end-of-packet) and consume the block, as it contains information not transferred to the RAPI672 block.
8.6
Receive Any-PHY Interface
The Receive Any-PHY Interface (RAPI672) provides a low latency path for transferring data out of the partial packet buffer in the RHDL672 and onto the Receive Any-PHY Packet Interface (Rx APPI). The RAPI672 contains a FIFO block for latency control as well as to segregate the APPI timing domain from the SYSCLK timing domain. The RAPI672 contains the necessary logic to manage and respond to device polling from an upper layer device. The RAPI672 also provides the upper layer device with status information on a per packet basis.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
47
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
8.6.1 FIFO Storage and Control
The FIFO block temporarily stores channel data during transfer across the Rx APPI. RAPI672 burst data transfers are transaction based - a write burst data transfer must be complete before any data will be read, and all data must be completely read from the FIFO before any further data will be written into the FIFO. To support full Rx APPI bus rate, a double buffer scheme is used. While data is being read from one FIFO onto the Rx APPI, data can be written into the other FIFO. Because the bandwidth on the writer side of the FIFOs is higher than that on the reader side, the RAPI672 can maintain continuous full bandwidth transfer over the Rx APPI. A maximum of 256 bytes can be stored in each of the two FIFOs for any given burst transfer. A separate storage element samples the 10 bit channel ID to associate the data in that FIFO with a specific HDLC channel. This channel ID is prepended in-band as the first word of every burst data transfer across the Rx APPI. (The maximum length of a burst data transfer on the Rx APPI is therefore 129 words, including prepend.) The 3 most significant bits of the prepended word of each burst data transfer across the Rx APPI identify the FREEDM84A672 device associated with the transfer and reflect the value of the base address programmed in the RAPI672 Control register. The writer controller provides a means for writing data into the FIFOs. The writer controller indicates that it can accept data when there is at least one completely empty FIFO. In response, a burst transfer of data, up to a maximum of 256 bytes, is written into that empty FIFO. (The transfer is sourced by the upstream RHDL672 block which selects from those channels with data available using its round-robin algorithm.) The writer controller then informs the reader controller that data is available in that FIFO. The writer controller now switches to the other FIFO and repeats the process. When both FIFOs are full, the writer throttles the upstream RHDL672 block to prevent of any further data writes into the FIFOs. The reader controller provides a means of reading data out of the FIFOs onto the Rx APPI. When selected to do so, and the writer controller has indicated that at least one FIFO is full, the reader controller will read the data out of the FIFOs in the order in which they were filled. To prevent from overloading the Rx APPI with several small bursts of data, the RAPI672 automatically deselects after every burst transfer. This provides time for the upper layer device to detect an end of packet indication and possibly reselect a different FREEDM-84A672 device without having to store the extra word or two which may have been output onto the Rx APPI during the time it took for deselection. The RAPI672 provides packet status information on the Rx APPI at the end of every packet transfer. The RAPI672 asserts RERR at the end of packet
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
48
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
reception (REOP high) to indicate that the packet is in error. The RAPI672 may optionally be programmed to overwrite RXDATA[7:0] of the final word of each packet transfer (REOP is high) with the status of packet reception when that packet is errored (RERR is high). Overwriting of status information is enabled by setting the STATEN bit in the RAPI Control register.
8.6.2 Polling Control and Management
The RAPI672 only responds to device polls which match the base address programmed in the RAPI672 Control register. A positive poll response indicates that at least one of the two FIFOs has a complete XFER[3:0] plus one blocks of data, or an end of packet, and is ready to be selected to transfer this data across the Rx APPI.
8.7
Transmit Any-PHY Interface
The Transmit Any-PHY Interface (TAPI672) provides a low latency path for transferring data from the Transmit Any-PHY Packet Interface (Tx APPI) into the partial packet buffer in the THDL672. The TAPI672 contains a FIFO block for latency control as well as to segregate the APPI timing domain from the SYSCLK timing domain. The TAPI672 contains the necessary logic to manage and respond to channel polling from an upper layer device.
8.7.1 FIFO Storage and Control
The FIFO block temporarily stores channel data during transfer across the Tx APPI. TAPI672 burst data transfers are transaction based on the writer side of the FIFO - all data must be completely read from the FIFO before any further data will be written into the FIFO. To support as close as possible to full Tx APPI bus rate, a double buffer is used. While data is being read from the one FIFO, data can be written into the other FIFO. Because the bandwidth on the reader side of the FIFOs is higher than that on the writer side, the TAPI672 will not incur any bandwidth reduction to maximum burst data transfers through its FIFOs. The upper layer device cannot interrupt data transfers on the Tx APPI. However, the FREEDM-84A672 may throttle the upper layer device if both FIFOs in the TAPI672 are full. When the FIFOs in the TAPI672 cannot accept data, the TAPI672 deasserts the TRDY output to the upper layer device connected to the Tx APPI. In this instance, the upper layer device must halt data transfer until the TRDY output is returned high. The upper layer device connected to the Tx APPI must sample the TRDY output high before continuing to burst data across the Tx APPI.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
49
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
A maximum of 256 bytes may be stored in each of the two FIFOs for any given burst transfer. The first word of each burst transfer contains a prepended address field. (The maximum length of a burst transfer on the Tx APPI is therefore 129 words, including prepend.) A separate storage element samples the 10 least significant bits of the prepended channel address to associate the data with a specific channel. The 3 most significant bits must match the base address programmed into the TAPI672 Control register for the TAPI672 to respond to the data transaction on the Tx APPI. The writer controller provides a means for writing data from the Tx APPI into the FIFOs. The writer controller can accept data when there is at least one completely empty FIFO. When a data transfer begins and there are no empty FIFOs, the writer controller catches the data provided on the Tx APPI and throttles the upper layer device. The writer controller will continue to throttle the upper layer device until at least one FIFO is completely empty and can accept a maximum burst transfer of data. The whisper controller provides the channel address of the data being written into the FIFO. As soon as the first word of data has been written into the FIFO, the whisper controller provides the channel information for that data to the downstream THDL672 block. The whisper controller will wait for acknowledgement and the reader controller is then requested to read the data from the FIFO. Once the reader controller has commenced the data transfer, the whisper controller will provide the channel information for the other FIFO. The whisper controller alternates between the two FIFOs in the order in which data is written into them. The reader controller provides a means of reading data out of the FIFOs. When the writer controller indicates that data has been completely written into one of the two FIFOs, the reader controller is permitted to read that data. The reader controller will then wait for a request for data from the THDL672 block. When requested to transfer data, the reader controller will completely read all the data out of the FIFO before indicating to the writer controller that more data may be written into that FIFO. Because the reader controller reads data out of the FIFOs in the order in which they were filled, the THDL672 block will request data for channels in the order in which they were whispered. The reader controller manages the read and write FIFO pointers to allow simultaneous reading and writing of data to/from the double buffer FIFO.
8.7.2 Polling Control and Management
The TAPI672 only responds to poll addresses which are in the range programmed in the base address field in the TAPI672 Control register. The TAPI672 uses the 3 most significant bits of the poll address for device recognition
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
50
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
and the 10 least significant bits of the poll address for identification of a channel. The TAPI672 provides three poll results for every poll address according to Table 9. The TPAn[0] bit indicates whether or not space exists in the channel FIFO for data and the TPAn[1] bit indicates whether or not that polled channel FIFO is at risk of underflowing and should be provided data soon. The TPAn[2] bit indicates that an underflow event has occurred on that channel FIFO.
Table 9 - Transmit Polling Poll Address
Channel 0 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 * * * Channel 671
TPA1[0]
(Full/Space)
TPA1[1]
(Space/Starving)
TPA1[2]
(Underflow)
TPA2[0]
(Full/Space)
TPA2[1]
(Space/Starving)
TPA2[2]
(Underflow)
Channel 0 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 * * * Channel 671
Channel 0 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 * * * Channel 671
Channel 0 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 * * * Channel 671
Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 * * * Channel 0
Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 * * * Channel 0
Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 * * * Channel 0
The TAPI672 maintains a mirror image of the status of each channel FIFO in the partial packet buffer. The THDL672 continuously reports the status of the 672 channel FIFOs to the TAPI672 and the TAPI672 updates the mirror image accordingly. The THDL672 also signals to the TAPI672 whenever an underflow event has occurred on a channel FIFO. At the beginning of every data transfer across the Tx APPI, the TAPI672 sets the mirror image status of the channel to "full". Only the TAPI672 can cause the status to be set to "full" and only the THDL672 can cause the status to be set to "space" or "starving". Only the THDL672 can cause the status to be set to "underflow" and only the TAPI672 can clear the "underflow" status when that channel FIFO is polled. In the event that both the TAPI672 and the THDL672 try to change the mirror image status of a particular channel simultaneously, the TAPI672 takes precedence, except for the "underflow" status, where the THDL672 takes precedence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
51
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
8.8
Transmit HDLC Controller / Partial Packet Buffer
The Transmit HDLC Controller / Partial Packet Buffer block (THDL672) contains a partial packet buffer for Tx APPI latency control and a transmit HDLC controller. The THDL672 also contains logic to monitor the full/empty status of each channel FIFO and push this status onto the polling interface signals. The THDL672 requests data from the TAPI672 in response to control information from the TAPI672 indicating the channel for which data is available and ready to be transferred. Packet data received from the TAPI672 is stored in channel specific FIFOs residing in the partial packet buffer. When the amount of data in a FIFO reaches a programmable threshold, the HDLC controller is enabled to initiate transmission. The HDLC controller performs flag generation, bit stuffing and, optionally, frame check sequence (FCS) insertion. The FCS is software selectable to be CRC-CCITT or CRC-32. The minimum packet size, excluding FCS, is two bytes. A single byte payload is illegal. The HDLC controller delivers data to the Transmit Channel Assigner block (TCAS672) on demand. A packet in progress is aborted if an under-run occurs. The THDL672 is programmable to operate in transparent mode where packet data retrieved from the TAPI672 is transmitted verbatim.
8.8.1 Transmit HDLC Processor
The HDLC processor is a time-slice state machine which can process up to 672 independent channels. The state vector and provisioning information for each channel is stored in a RAM. Whenever the TCAS672 requests data, the appropriate state vector is read from the RAM, processed and finally written back to the RAM. The HDLC state-machine can be configured to perform flag insertion, bit stuffing and CRC generation. The HDLC processor requests data from the partial packet processor whenever a request for channel data arrives. However, the HDLC processor does not start transmitting a packet until the entire packet is stored in the channel FIFO or until the FIFO free space is less than the software programmable limit. If a channel FIFO under-runs, the HDLC processor aborts the packet, generates a microprocessor interrupt and signals the underflow to the transmit Any-PHY interface. The configuration of the HDLC processor is accessed using indirect channel read and write operations. When an indirect operation is performed, the information is accessed from RAM during a null clock cycle inserted by the TCAS672 block. Writing new provisioning data to a channel resets the channel's entire state vector.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
52
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
8.8.2 Transmit Partial Packet Buffer Processor
The partial packet buffer processor controls the 32 Kbyte partial packet RAM which is divided into 16 byte blocks. A block pointer RAM is used to chain the partial packet blocks into circular channel FIFO buffers. Thus, non-contiguous sections of RAM can be allocated in the partial packet buffer RAM to create a channel FIFO. Figure 4 shows an example of three blocks (blocks 1, 3, and 200) linked together to form a 48 byte channel FIFO. The three pointer values would be written sequentially using indirect block write accesses. When a channel is provisioned within this FIFO, the state machine can be initialized to point to any one of the three blocks.
Figure 4 - Partial Packet Buffer Structure Partial Packet Buffer RAM
Block 0 Block 1 Block 2 Block 3 16 bytes 16 bytes 16 bytes 16 bytes Block 0 Block 1 Block 2 Block 3
Block Pointer RAM
XX 0x03 XX 0xC8
Block 200
16 bytes
Block 200
0x01
Block 2047
16 bytes
Block 2047
XX
The partial packet buffer processor is divided into three sections: reader, writer and roamer. The roamer is a time-sliced state machine which tracks each channel's FIFO buffer free space and signals the writer to service a particular channel. The writer requests data from the TAPI672 block and transfers packet data from the TAPI672 to the associated channel FIFO. The reader is a time-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
53
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
sliced state machine which transfers the HDLC information from a channel FIFO to the HDLC processor in response to a request from the HDLC processor. If a buffer under-run occurs for a channel, the reader informs the HDLC processor and purges the rest of the packet. If a buffer overflow occurs for a channel (this can only happen if an external device disregards or mis-interprets poll results on the Tx APPI and transfers data to a channel which does not have space in its FIFO), the THDL672 overwrites the FIFO contents resulting in data corruption on that particular channel. When either an underflow or an overflow occurs, an interrupt is generated and the cause of the interrupt may be read via the interrupt status register using the microprocessor interface. The writer and reader determine empty and full FIFO conditions using flags. Each block in the partial packet buffer has an associated flag. The writer sets the flag after the block is written and the reader clears the flag after the block is read. The flags are initialized (cleared) when the block pointers are written using indirect block writes. The reader declares a channel FIFO under-run whenever it tries to read data from a block without a set flag. The FIFO algorithm of the partial packet buffer processor is based on perchannel software programmable transfer size and free space trigger level. Instead of tracking the number of full blocks in a channel FIFO, the processor tracks the number of empty blocks, called free space, as well as the number of end of packets stored in the FIFO. Recording the number of empty blocks instead of the number of full blocks reduces the amount of information the roamer must store in its state RAM. The partial packet roamer records the FIFO free space and end-of-packet count for all channel FIFOs. When the reader signals that a block has been read, the roamer increments the FIFO free space and sets a per-channel request flag if the free space is greater than the limit set by XFER[3:0]. The roamer pushes this status information to the TAPI672 to indicate that it can accept at least XFER[3:0] blocks of data. The roamer also decrements the end-of-packet count when the reader signals that it has passed an end of a packet to the HDLC processor. If the HDLC processor is transmitting a packet and the FIFO free space is greater than the starving trigger level and there are no complete packets within the FIFO (end-of-packet count equal to zero), a per-channel starving flag is set. The roamer searches the starving flags in a round-robin fashion to decide which channel FIFOs are at risk of underflowing and pushes this status information to the TAPI672. The roamer listens to control information from the TAPI672 to decide which channel FIFO requests data from the TAPI672 block. The roamer informs the partial packet writer of the channel FIFO to process and the FIFO free space. The writer sends a request for data to the TAPI672 block, writes the response data to the channel FIFO, and sets the block full flags. The writer reports back to the roamer the number of blocks and end-of-packets transferred.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
54
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
The maximum amount of data transferred during one request is limited by a software programmable limit (XFER[3:0]). The roamer round-robins between all channel FIFOs and pushes the status to the TAPI672 block. The status consists of two pieces of information: (1) is there space in the channel FIFO for at least one XFER[3:0] of data, and (2) is this channel FIFO at risk of underflowing. Where a channel FIFO is at risk of underflowing, the THDL672 pushes a starving status for that channel FIFO to the TAPI672 at the earliest possible opportunity. The configuration of the HDLC processor is accessed using indirect channel read and write operations as well as indirect block read and write operations. When an indirect operation is performed, the information is accessed from RAM during a null clock cycle identified by the TCAS672 block. Writing new provisioning data to a channel resets the entire state vector.
8.9
Transmit Channel Assigner
The Transmit Channel Assigner block (TCAS672) processes up to 672 channels. Data for all channels is sourced from a single byte-serial stream from the Transmit HDLC Controller / Partial Packet Buffer block (THDL672). The TCAS672 demultiplexes the data and assigns each byte to any one of 84 links. When sending data to the SBI SIPO blocks, each link may be configured to support channelised T1/J1/E1 traffic, unchannelised DS-3 traffic or unframed traffic at T1/J1, E1 or DS-3 rates. When sending data to the TD outputs, links 0, 1 and 2 support unchannelised data at arbitary rates up to 51.84 Mbps. Each link is independent and has its own associated clock. The 84 TCAS links have a fixed relationship to the SPE and tributary numbers on the SBI ADD BUS as shown in the following table.
Table 10 - SBI SPE/Tributary to TCAS Link Mapping SBI SPE No.
1 1 1 1 1
SBI Trib. No.
1 2 3 4 5
TCAS Link No.
0 3 6 9 12
SBI SPE No.
2 2 2 2 2
SBI Trib. No.
1 2 3 4 5
TCAS Link No.
1 4 7 10 13
SBI SPE No.
3 3 3 3 3
SBI Trib. No.
1 2 3 4 5
TCAS Link No.
2 5 8 11 14
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
55
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
SBI SPE No. 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
SBI Trib. No. 6
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
TCAS Link No. 15
18 21 24 27 30 33 36 39 42 45 48 51 54 57 60 63 66 69 72 75 78 81
SBI SPE No. 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
SBI Trib. No. 6
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
TCAS Link No. 16
19 22 25 28 31 34 37 40 43 46 49 52 55 58 61 64 67 70 73 76 79 82
SBI SPE No. 3
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
SBI Trib. No. 6
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
TCAS Link No. 17
20 23 26 29 32 35 38 41 44 47 50 53 56 59 62 65 68 71 74 77 80 83
As shown in the table above, TCAS links 0, 1, and 2 are mapped to tributary 1 of SPEs 1, 2 and 3 respectively. These links may be configured to operate at DS-3 rate. (They may also be configured to output data to the TD outputs at rates up to 51.84 Mbps.) For each of these high-speed links, the TCAS672 provides a six byte FIFO. For the remaining links (TCAS links 3 to 83, mapped to tributaries 2
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
56
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
to 28 of each SPE), the TCAS672 provides a single byte holding register. The TCAS672 performs parallel to serial conversion to form bit-serial streams which are passed to the SBI SIPO blocks. In the event where multiple links are in need of data, TCAS672 requests data from upstream blocks on a fixed priority basis with link 0 having the highest priority and link 83 the lowest. Links containing a T1/J1 or an E1 stream may be channelised. Data at each time-slot may be independently assigned to be sourced from a different channel. The position of T1/J1 and E1 framing bits/bytes is identified by frame pulse signals generated by the SBI SIPO blocks. With knowledge of the transmit link and time-slot identity, the TCAS672 performs a table look-up to identify the channel from which a data byte is to be sourced. Links containing a DS-3 stream are unchannelised, in which case, all data bytes on the link belong to one channel. The TCAS672 performs a table look-up to identify the channel to which a data byte belongs using only the outgoing link identity, as no time-slots are associated with unchannelised links. Links may additionally be configured to operate in an unframed "clear channel" mode, in which case the FREEDM-84A672 will output HDLC data in all bit positions, including those normally reserved for framing information. Links so configured operate as unchannelised regardless of link rate and the TCAS672 performs a table lookup using only the link number to determine the associated channel.
8.9.1 Line Interface
There are 84 line interface blocks in the TCAS672. Each line interface block contains a bit counter, an 8-bit shift register and a holding register that, together, perform parallel to serial conversion. Whenever the shift register is updated, a request for service is sent to the priority encoder block. When acknowledged by the priority encoder, the line interface responds by writing the data into the holding register. To support channelised links, each line interface block contains a time-slot counter. The time-slot counter is incremented each time the shift register is updated and is reset on detection of a frame pulse from the SBI SIPO blocks. For unchannelised or unframed links, the time-slot counter is held reset.
8.9.2 Priority Encoder
The priority encoder monitors the line interfaces for requests and synchronises them to the SYSCLK timing domain. Requests are serviced on a fixed priority scheme where highest to lowest priority is assigned from the line interface attached to link 0 to that attached to link 83. Thus, simultaneous requests from link `m' will be serviced ahead of link `n', if m < n. The priority encoder selects the
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
57
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
request from the link with the highest priority for service. When there are no pending requests, the priority encoder generates an idle cycle. In addition, once every fourth SYSCLK cycle, the priority encoder inserts a null cycle where no requests are serviced. This cycle is used by the channel assigner upstream for CBI accesses to the channel provision RAM.
8.9.3 Channel Assigner
The channel assigner block determines the channel number of the request currently being processed. The block contains a 2688 word channel provision RAM. The address of the RAM is constructed from concatenating the link number and the time-slot number of the highest priority requester. The fields of each RAM word include the channel number and a time-slot enable flag. The time-slot enable flag labels the current time-slot as belonging to the channel indicted by the channel number field. For time-slots that are enabled, the channel assigner issues a request to the THDL672 block which responds with packet data within one byte period of the transmit stream.
8.10 SBI Inserter and SIPO
The SBI transmit circuitry consists of an SBI Insert block and three SBI Serial to Parallel Converter (SBI SIPO) blocks. Each SIPO block processes data for one of the three Synchronous Payload Envelopes (SPEs) conveyed on the SBI ADD BUS. It receives serial data on either 28 links running at T1/J1 rate, 21 links at E1 rate or a single link at DS-3 rate and converts it to an internal parallel bus format. The SBI Insert block receives data from the SIPO blocks in the internal format and transmits it on the SBI ADD BUS. The SIPO blocks generate the serial clocks for the TCAS672 and thus are able to control the rate at which data is transmitted on to the SBI. The SBI Insert block can command the SIPO blocks to speed up or slow down these clocks in response to justfication requests received on the SBI interface. The SBI Insert block also contains FIFO circuitry to compensate for short term variations in the rate at which data is output by the TCAS672 and the rate at which it is transmitted on the SBI ADD BUS. The SBI Insert block may be configured to enable or disable transmission of individual tributaries on to the SBI ADD bus. Individual tributaries may also be configured to operate in framed or unframed mode.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
58
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
8.11 Performance Monitor
The Performance Monitor block (PMON) contains four counters. The first two accumulate receive partial packet buffer FIFO overrun events and transmit partial packet buffer FIFO underflow events, respectively. The remaining two counters are software programmable to accumulate a variety of events, such as receive packet count, FCS error counts, etc. All counters saturate upon reaching maximum value. The accumulation logic consists of a counter and holding register pair. The counter is incremented when the associated event is detected. Writing to the FREEDM-84A672 Master Clock / Frame Pulse Activity Monitor and Accumulation Trigger register transfer the count to the corresponding holding register and clear the counter. The contents of the holding register is accessible via the microprocessor interface.
8.12 JTAG Test Access Port Interface
The JTAG Test Access Port block provides JTAG support for boundary scan. The standard JTAG EXTEST, SAMPLE, BYPASS, IDCODE and STCTEST instructions are supported. The FREEDM-84A672 identification code is 073850CD hexadecimal.
8.13 Microprocessor Interface
The FREEDM-84A672 supports microprocessor access to an internal register space for configuring and monitoring the device. All registers are 16 bits wide but are DWORD aligned in the microprocessor memory map. The registers are described below:
Table 11 - Normal Mode Microprocessor Accessible Registers Address
0x000 0x004 0x008 0x00C 0x010 0x014 0x018 - 0x020
Register
FREEDM-84A672 Master Reset FREEDM-84A672 Master Interrupt Enable FREEDM-84A672 Master Interrupt Status FREEDM-84A672 Master Clock / Frame Pulse Activity Monitor and Accumulation Trigger FREEDM-84A672 Reserved FREEDM-84A672 Master Line Loopback FREEDM-84A672 Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
59
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Address
0x024 0x028 0x02C 0x030 0x034 0x038 0x03C 0x040 0x044 0x048 0x04C 0x050 - 0x0FC 0x100 0x104 0x108 0x10C 0x110 - 0x13C 0x140 0x144 0x148 0x14C 0x150 0x154 0x158 - 0x17C 0x180 - 0x188 0x18C - 0x1FC 0x200 0x204
Register
FREEDM-84A672 Master Performance Monitor Control FREEDM-84A672 Master SBI Interrupt Enable FREEDM-84A672 Master SBI Interrupt Status FREEDM-84A672 Master Tributary Loopback #1 FREEDM-84A672 Master Tributary Loopback #2 FREEDM-84A672 Master Tributary Loopback #3 FREEDM-84A672 Master Tributary Loopback #4 FREEDM-84A672 Master Tributary Loopback #5 FREEDM-84A672 Master Tributary Loopback #6 FREEDM-84A672 SBI DROP BUS Master Configuration FREEDM-84A672 SBI ADD BUS Master Configuration Reserved RCAS Indirect Channel and Time-slot Select RCAS Indirect Channel Data RCAS Reserved RCAS Channel Disable RCAS Reserved RCAS SBI SPE1 Configuration Register #1 RCAS SBI SPE1 Configuration Register #2 RCAS SBI SPE2 Configuration Register #1 RCAS SBI SPE2 Configuration Register #2 RCAS SBI SPE3 Configuration Register #1 RCAS SBI SPE3 Configuration Register #2 RCAS Reserved RCAS Link #0 to #2 Configuration RCAS Reserved RHDL Indirect Channel Select RHDL Indirect Channel Data Register #1
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
60
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Address
0x208 0x20C 0x210 0x214 0x218 - 0x21C 0x220 0x224 0x228 - 0x23C 0x240 - 0x37C 0x380 0x384 0x388 0x38C 0x390 - 0x39C 0x3A0 0x3A4 0x3A8 - 0x3AC 0x3B0 0x3B4 - 0x3BC 0x3C0 - 0x3FC 0x400 0x404 0x408 0x40C 0x410 0x414 - 0x43C 0x440 0x444
Register
RHDL Indirect Channel Data Register #2 RHDL Reserved RHDL Indirect Block Select RHDL Indirect Block Data Register RHDL Reserved RHDL Configuration RHDL Maximum Packet Length RHDL Reserved Reserved THDL Indirect Channel Select THDL Indirect Channel Data #1 THDL Indirect Channel Data #2 THDL Indirect Channel Data #3 THDL Reserved THDL Indirect Block Select THDL Indirect Block Data THDL Reserved THDL Configuration THDL Reserved Reserved TCAS Indirect Channel and Time-slot Select TCAS Indirect Channel Data TCAS Reserved TCAS Idle Time-slot Fill Data TCAS Channel Disable TCAS Reserved TCAS SBI SPE1 Configuration Register #1 TCAS SBI SPE1 Configuration Register #2
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
61
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Address
0x448 0x44C 0x450 0x454 0x458 - 0x47C 0x480 - 0x488 0x48C - 0x4FC 0x500 0x504 0x508 0x50C 0x510 0x514 - 0x51C 0x520 - 0x57C 0x580 0x584 - 0x5BC 0x5C0 0x5C4 - 0x5C8 0x5CC 0x5D0 0x5D4 0x5D8 0x5DC 0x5E0 - 0x5FC 0x600 0x604 0x608 0x60C - 0x63C
Register
TCAS SBI SPE2 Configuration Register #1 TCAS SBI SPE2 Configuration Register #2 TCAS SBI SPE3 Configuration Register #1 TCAS SBI SPE3 Configuration Register #2 TCAS Reserved TCAS Link #0 to #2 Configuration TCAS Reserved PMON Status PMON Receive FIFO Overflow Count PMON Transmit FIFO Underflow Count PMON Configurable Count #1 PMON Configurable Count #2 PMON Reserved Reserved RAPI Control RAPI Reserved SBI EXTRACT Control SBI EXTRACT Reserved SBI EXTRACT Tributary RAM Indirect Access Address SBI EXTRACT Tributary RAM Indirect Access Control SBI EXTRACT Reserved SBI EXTRACT Tributary RAM Indirect Access Data SBI EXTRACT Parity Error Interrupt Reason SBI EXTRACT Reserved TAPI Control TAPI Indirect Channel Provisioning TAPI Indirect Channel Data Register TAPI Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
62
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Address
0x640 - 0x67C 0x680 0x684 - 0x688 0x68C 0x690 0x694 0x698 0x69C - 0x6FC 0x700 - 0x7FC
Register
Reserved SBI INSERT Control SBI INSERT Reserved SBI INSERT Tributary RAM Indirect Access Address SBI INSERT Tributary RAM Indirect Access Control SBI INSERT Reserved SBI INSERT Tributary RAM Indirect Access Data SBI INSERT Reserved Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
63
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
9
NORMAL MODE REGISTER DESCRIPTION
Normal mode registers are used to configure and monitor the operation of the FREEDM-84A672.
Notes on Normal Mode Register Bits:
1. Writing values into unused register bits has no effect. However, to ensure software compatibility with future, feature-enhanced versions of the product, unused register bits must be written with logic zero. Reading back unused bits can produce either a logic one or a logic zero; hence, unused register bits should be masked off by software when read. 2. Except where noted, all configuration bits that can be written into can also be read back. This allows the processor controlling the FREEDM-84A672 to determine the programming state of the block. 3. Writable normal mode register bits are cleared to logic zero upon reset unless otherwise noted. 4. Writing into read-only normal mode register bit locations does not affect FREEDM84A672 operation unless otherwise noted. 5. Certain register bits are reserved. These bits are associated with megacell functions that are unused in this application. To ensure that the FREEDM-84A672 operates as intended, reserved register bits must only be written with their default values. Similarly, writing to reserved registers should be avoided.
9.1
Microprocessor Accessible Registers
Microprocessor accessible registers can be accessed by the external microprocessor. For each register description below, the hexadecimal register number indicates the address in the FREEDM-84A672 when accesses are made using the external microprocessor.
Note
These registers are not byte addressable. Writing to any one of these registers modifies all 16 bits in the register.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
64
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x000 : FREEDM-84A672 Master Reset Bit
Bit 15 Bit 14 to Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R R R R R R R R R R R R
Type
R/W
Function
Reset Unused
Default
0 XH
TYPE[3] TYPE[2] TYPE[1] TYPE[0] ID[7] ID[7] ID[5] ID[4] ID[3] ID[2] ID[1] ID[0]
0 1 0 1 0 0 0 0 0 0 1 0
This register provides software reset capability and device ID information. RESET: The RESET bit allows the FREEDM-84A672 to be reset under software control. If the RESET bit is a logic one, the entire FREEDM-84A672, except the microprocessor interface, is held in reset. In addition, all registers are reset to their default values. This bit is not self-clearing. Therefore, a logic zero must be written to bring the FREEDM-84A672 out of reset. Holding the FREEDM-84A672 in a reset state places it into a low power, stand-by mode. A hardware reset clears the RESET bit, thus negating the software reset.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
65
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Note
Unlike the hardware reset input (RSTB), RESET does not force the FREEDM84A672's microprocessor interface pins tristate. RESET causes all registers to be set to their default values and forces the APPI outputs tristate. TYPE[3:0]: The Device Type bits (TYPE[3:0]) allow software to identify the device as the FREEDM-84A672 member of the FREEDM family of products. ID[7:0]: The Device ID bits (ID[7:0]) allow software to identify the version level of the FREEDM-84A672.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
66
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x004 : FREEDM-84A672 Master Interrupt Enable Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 to Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W
Type
R/W R/W R/W R/W
Function
TFUDRE TFOVRE TUNPVE TPRTYE Unused
Default
0 0 0 0 XXH
RFOVRE RPFEE RABRTE RFCSEE Unused Unused
0 0 0 0 X X
This register provides interrupt enables for various events detected or initiated by the FREEDM-84A672. RFCSEE: The receive frame check sequence error interrupt enable bit (RFCSEE) enables receive FCS error interrupts to the microprocessor. When RFCSEE is set high, a mismatch between the received FCS code and the computed CRC residue will cause an interrupt to be generated on the INTB output. Interrupts are masked when RFCSEE is set low. However, the RFCSEI bit remains valid when interrupts are disabled and may be polled to detect receive FCS error events. RABRTE: The receive abort interrupt enable bit (RABRTE) enables receive HDLC abort interrupts to the microprocessor. When RABRTE is set high, receipt of an abort code (at least 7 contiguous 1's) will cause an interrupt to be generated on the INTB output. Interrupts are masked when RABRTE is set low. However, the RABRTI bit remains valid when interrupts are disabled and may be polled to detect receive abort events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
67
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
RPFEE: The receive packet format error interrupt enable bit (RPFEE) enables receive packet format error interrupts to the microprocessor. When RPFEE is set high, receipt of a packet that is longer than the maximum specified in the RHDL Maximum Packet Length register, or a packet that is shorter than 32 bits (CRC-CCITT) or 48 bits (CRC-32), or a packet that is not octet aligned will cause an interrupt to be generated on the INTB output. Interrupts are masked when RPFEE is set low. However, the RPFEI bit remains valid when interrupts are disabled and may be polled to detect receive packet format error events. RFOVRE: The receive FIFO overrun error interrupt enable bit (RFOVRE) enables receive FIFO overrun error interrupts to the microprocessor. When RFOVRE is set high, attempts to write data into the logical FIFO of a channel when it is already full will cause an interrupt to be generated on the INTB output. Interrupts are masked when RFOVRE is set low. However, the RFOVRI bit remains valid when interrupts are disabled and may be polled to detect receive FIFO overrun events. TPRTYE: The transmit parity error interrupt enable bit (TPRTYE) enables parity errors on the transmit APPI to generate interrupts to the microprocessor. When TPRTYE is set high, detection of a parity error on the transmit APPI will cause an interrupt to be generated on the INTB output. Interrupts are masked when TPRTYE is set low. However, the TPRTYI bit remains valid when interrupts are disabled and may be polled to detect parity error events. TUNPVE: The transmit unprovisioned error interrupt enable bit (TUNPVE) enables attempted transmissions to unprovisioned channels to generate interrupts to the microprocessor. When TUNPVE is set high, attempts to write data to an unprovisioned channel will cause an interrupt to be generated on the INTB output. Interrupts are masked when TUNPVE is set low. However, the TUNPVI bit remains valid when interrupts are disabled and may be polled to detect attempted transmissions to unprovisioned channel events. TFOVRE: The transmit FIFO overflow error interrupt enable bit (TFOVRE) enables transmit FIFO overflow error interrupts to the microprocessor. When TFOVRE is set high, attempts to write data to the logical FIFO when it is already full will cause an interrupt to be generated on the INTB output.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
68
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Interrupts are masked when TFOVRE is set low. However, the TFOVRI bit remains valid when interrupts are disabled and may be polled to detect transmit FIFO overflow events. TFUDRE: The transmit FIFO underflow error interrupt enable bit (TFUDRE) enables transmit FIFO underflow error interrupts to the microprocessor. When TFUDRE is set high, attempts to read data from the logical FIFO when it is already empty will cause an interrupt to be generated on the INTB output. Interrupts are masked when TFUDRE is set low. However, the TFUDRI bit remains valid when interrupts are disabled and may be polled to detect transmit FIFO underflow events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
69
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x008 : FREEDM-84A672 Master Interrupt Status Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 to Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R R R R
Type
R R R R
Function
TFUDRI TFOVRI TUNPVI TPRTYI Unused
Default
X X X X XXH
RFOVRI RPFEI RABRTI RFCSEI Unused Unused
X X X X X X
This register reports the interrupt status for various events detected or initiated by the FREEDM-84A672. Reading this registers acknowledges and clears the interrupts. RFCSEI: The receive frame check sequence error interrupt status bit (RFCSEI) reports receive FCS error interrupts to the microprocessor. RFCSEI is set high when a mismatch between the received FCS code and the computed CRC residue is detected. RFCSEI remains valid when interrupts are disabled and may be polled to detect receive FCS error events. RABRTI: The receive abort interrupt status bit (RABRTI) reports receive HDLC abort interrupts to the microprocessor. RABRTI is set high upon receipt of an abort code (at least 7 contiguous 1's). RABRTI remains valid when interrupts are disabled and may be polled to detect receive abort events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
70
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
RPFEI: The receive packet format error interrupt status bit (RPFEI) reports receive packet format error interrupts to the microprocessor. RPFEI is set high upon receipt of a packet that is longer than the maximum programmed length, of a packet that is shorter than 32 bits (CRC-CCITT) or 48 bits (CRC-32), or of a packet that is not octet aligned. RPFEI remains valid when interrupts are disabled and may be polled to detect receive packet format error events. RFOVRI: The receive FIFO overrun error interrupt status bit (RFOVRI) reports receive FIFO overrun error interrupts to the microprocessor. RFOVRI is set high on attempts to write data into the logical FIFO of a channel when it is already full. RFOVRI remains valid when interrupts are disabled and may be polled to detect receive FIFO overrun events. TPRTYI: The transmit parity error interrupt status bit (TPRTYI) reports the detection of a parity on the transmit APPI. TPRTYI is set high upon detection of a parity error. TPRTYI remains valid when interrupts are disabled and may be polled to detect parity errors. TUNPVI: The transmit unprovisioned error interrupt status bit (TUNPVI) reports an attempted data transmission to an unprovisioned channel FIFO. TUNPVI is set high upon attempts to write data to an unprovisioned channel FIFO. TUNPVI remains valid when interrupts are disabled and may be polled to detect an attempt to write data to an unprovisioned channel FIFO. TFOVRI: The transmit FIFO overflow error interrupt status bit (TFOVRI) reports transmit FIFO overflow error interrupts to the microprocessor. TFOVRI is set high upon attempts to write data to the logical FIFO when it is already full. TFOVRI remains valid when interrupts are disabled and may be polled to detect transmit FIFO overflow events. (Note - Transmit FIFO overflows will not occur if channels are properly polled on the Transmit APPI before transferring data.) TFUDRI: The transmit FIFO underflow error interrupt status bit (TFUDRI) reports transmit FIFO underflow error interrupts to the microprocessor. TFUDRI is set high upon attempts to read data from the logical FIFO when it is already
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
71
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
empty. TFUDRI remains valid when interrupts are disabled and may be polled to detect transmit FIFO underflow events.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
72
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x00C : FREEDM-84A672 Master Clock / Frame Pulse Activity Monitor and Accumulation Trigger Bit
Bit 15 to Bit 14 Bit 13 Bit 12 Bit 11 to Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R R R R R R
Type
Function
Unused
Default
XH
TXCLKA RXCLKA Unused
X X XH
C1FPA FASTCLKA REFCLKA SYSCLKA
X X X X
This register provides activity monitoring on the FREEDM-84A672 clock and SBI frame pulse inputs. When a monitored input makes a transition, the corresponding register bit is set high. The bit will remain high until this register is read, at which point, all the bits in this register are cleared. A lack of transitions is indicated by the corresponding register bit reading low. This register should be read periodically to detect for stuck at conditions. Writing to this register delimits the accumulation intervals in the PMON accumulation registers. Counts accumulated in those registers are transferred to holding registers where they can be read. The counters themselves are then cleared to begin accumulating events for a new accumulation interval. The bits in this register are not affected by write accesses. SYSCLKA: The system clock active bit (SYSCLKA) monitors for low to high transitions on the SYSCLK input. SYSCLKA is set high on a rising edge of SYSCLK, and is set low when this register is read.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
73
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
REFCLKA: The SBI reference clock active bit (REFCLKA) monitors for low to high transitions on the REFCLK input. REFCLKA is set high on a rising edge of REFCLK, and is set low when this register is read. FASTCLKA: The SBI fast clock active bit (FASTCLKA) monitors for low to high transitions on the FASTCLK input. FASTCLKA is set high on a rising edge of FASTCLK, and is set low when this register is read. C1FPA: The SBI frame pulse active bit (C1FPA) monitors for low to high transitions on the C1FP input. C1FPA is set high on a rising edge of C1FP, and is set low when this register is read. RXCLKA: The Any-PHY receive clock active bit (RXCLKA) monitors for low to high transitions on the RXCLK input. RXCLKA is set high on a rising edge of RXCLK, and is set low when this register is read. TXCLKA: The Any-PHY transmit clock active bit (TXCLKA) monitors for low to high transitions on the TXCLK input. TXCLKA is set high on a rising edge of TXCLK, and is set low when this register is read.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
74
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x014 : FREEDM-84A672 Master Line Loopback Bit
Bit 15 to Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W
Function
Reserved
Default
0000H
R/W R/W R/W
LLBEN[2] LLBEN[1] LLBEN[0]
0 0 0
This register controls line loopback for the three serial data links (enabled when SPEn_EN is low). LLBEN[2:0]: The line loopback enable bits (LLBEN[2:0]) control line loopback for links #2 to #0. When LLBEN[n] is set high, the data on RD[n] is passed verbatim to TD[n] which is then updated on the falling edge of RCLK[n]. TCLK[n] is ignored. When LLBEN[n] is set low, TD[n] is processed normally.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
75
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x024 : FREEDM-84A672 Master Performance Monitor Control Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
Function
Unused TP2EN TABRT2EN RP2EN RLENE2EN RABRT2EN RFCSE2EN RSPE2EN Unused TP1EN TABRT1EN RP1EN RLENE1EN RABRT1EN RFCSE1EN RSPE1EN
Default
X 0 0 0 0 0 0 0 X 0 0 0 0 0 0 0
This register configures the events that are accumulated in the two configurable performance monitor counters in the PMON block. RSPE1EN: The receive small packet error accumulate enable bit (RSPE1EN) enables counting of minimum packet size violation events. When RSPE1EN is set high, receipt of a packet that is shorter than 32 bits (CRC-CCITT, Unspecified CRC or no CRC) or 48 bits (CRC-32) will cause the PMON Configurable Accumulator #1 register to increment. Small packet errors are ignored when RSPE1EN is set low. RFCSE1EN: The receive frame check sequence error accumulate enable bit (RFCSE1EN) enables counting of receive FCS error events. When RFCSE1EN is set high,
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
76
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
a mismatch between the received FCS code and the computed CRC residue will cause the PMON Configurable Accumulator #1 register to increment. Receive frame check sequence errors are ignored when RFCSE1EN is set low. RABRT1EN: The receive abort accumulate enable bit (RABRT1EN) enables counting of receive HDLC abort events. When RABRT1EN is set high, receipt of an abort code (at least 7 contiguous 1's) will cause the PMON Configurable Accumulator #1 register to increment. Receive aborts are ignored when RABRT1EN is set low. RLENE1EN: The receive packet length error accumulate enable bit (RLENE1EN) enables counting of receive packet length error events. When RLENE1EN is set high, receipt of a packet that is longer than the programmable maximum or of a packet that in not octet aligned will cause the PMON Configurable Accumulator #1 register to increment. (Receipt of a packet that is both too long and not octet aligned results in only one increment.) Receive packet length errors are ignored when RLENE1EN is set low. RP1EN: The receive packet enable bit (RP1EN) enables counting of receive error-free packets. When RP1EN is set high, receipt of an error-free packet will cause the PMON Configurable Accumulator #1 register to increment. Receive errorfree packets are ignored when RP1EN is set low. TABRT1EN: The transmit abort accumulate enable bit (TABRT1EN) enables counting of transmit HDLC abort events. When TABRT1EN is set high, insertion of an abort in the outgoing stream will cause the PMON Configurable Accumulator #1 register to increment. Transmit aborts are ignored when TABRT1EN is set low. TP1EN: The transmit packet enable bit (TP1EN) enables counting of transmit error-free packets. When TP1EN is set high, transmission of an error-free packet will cause the PMON Configurable Accumulator #1 register to increment. Transmit error-free packets are ignored when TP1EN is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
77
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
RSPE2EN: The receive small packet error accumulate enable bit (RSPE2EN) enables counting of minimum packet size violation events. When RSPE2EN is set high, receipt of a packet that is shorter than 32 bits (CRC-CCITT, Unspecified CRC or no CRC) or 48 bits (CRC-32) will cause the PMON Configurable Accumulator #2 register to increment. Small packet errors are ignored when RSPE2EN is set low. RFCSE2EN: The receive frame check sequence error accumulate enable bit (RFCSE2EN) enables counting of receive FCS error events. When RFCSE2EN is set high, a mismatch between the received FCS code and the computed CRC residue will cause the PMON Configurable Accumulator #2 register to increment. Receive frame check sequence errors are ignored when RFCSE2EN is set low. RABRT2EN: The receive abort accumulate enable bit (RABRT2EN) enables counting of receive HDLC abort events. When RABRT2EN is set high, receipt of an abort code (at least 7 contiguous 2's) will cause the PMON Configurable Accumulator #2 register to increment. Receive aborts are ignored when RABRT2EN is set low. RLENE2EN: The receive packet length error accumulate enable bit (RLENE2EN) enables counting of receive packet length error events. When RLENE2EN is set high, receipt of a packet that is longer than the programmable maximum or of a packet that in not octet aligned will cause the PMON Configurable Accumulator #2 register to increment. (Receipt of a packet that is both too long and not octet aligned results in only one increment.) Receive packet length errors are ignored when RLENE2EN is set low. RP2EN: The receive packet enable bit (RP2EN) enables counting of receive error-free packets. When RP2EN is set high, receipt of an error-free packet will cause the PMON Configurable Accumulator #2 register to increment. Receive errorfree packets are ignored when RP2EN is set low. TABRT2EN: The transmit abort accumulate enable bit (TABRT2EN) enables counting of transmit HDLC abort events. When TABRT2EN is set high, insertion of an abort in the outgoing stream will cause the PMON Configurable Accumulator
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
78
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
#2 register to increment. Transmit aborts are ignored when TABRT2EN is set low. TP2EN: The transmit packet enable bit (TP2EN) enables counting of transmit error-free packets. When TP2EN is set high, transmission of an error-free packet will cause the PMON Configurable Accumulator #2 register to increment. Transmit error-free packets are ignored when TP2EN is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
79
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x028 : FREEDM-84A672 Master SBI Interrupt Enable Bit
Bit 15 to Bit 1 Bit 0 R/W
Type
Function
Unused
Default
XXH
SBIEXTE
0
This register provides interrupt enables for various events detected or initiated by the SBI circuitry within the FREEDM-84A672. SBIEXTE: The SBI Extracter interrupt enable bit (SBIEXTE) enables interrupts from the SBI Extract block to the microprocessor. When SBIEXTE is set high, an interrupt from the SBI Extract block will cause an interrupt to be generated on the INTB output. Interrupts are masked when SBIEXTE is set low. However, the SBIEXTI bit remains valid when interrupts are disabled and may be polled to detect interrupts from the SBI Extract Block.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
80
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x02C : FREEDM-84A672 Master SBI Interrupt Status Bit
Bit 15 to Bit 1 Bit 0 R
Type
Function
Unused
Default
XXH
SBIEXTI
X
This register reports the interrupt status for various events detected or initiated by the SBI circuitry within the FREEDM-84A672. Reading this register acknowledges and clears the interrupts. SBIEXTI: The SBI Extracter interrupt status bit (SBIEXTI) reports an error condition from the SBI Extract block to the microprocessor. SBIEXTI remains valid when interrupts are disabled and may be polled to detect SBI Extract block error conditions.
Note
The only error condition which the SBI Extract block reports is a parity error on the SBI DROP BUS. If parity errors occur, the SBI EXTRACT Parity Error Interrupt Reason register (0x5DC) may be read to obtain more detailed information concerning the error.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
81
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x030 : FREEDM-84A672 Master Tributary Loopback #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
SPE1_LBEN[16] SPE1_LBEN[15] SPE1_LBEN[14] SPE1_LBEN[13] SPE1_LBEN[12] SPE1_LBEN[11] SPE1_LBEN[10] SPE1_LBEN[9] SPE1_LBEN[8] SPE1_LBEN[7] SPE1_LBEN[6] SPE1_LBEN[5] SPE1_LBEN[4] SPE1_LBEN[3] SPE1_LBEN[2] SPE1_LBEN[1]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
This register controls line loopback for tributaries #1 to #16 of SPE #1. SPE1_LBEN[16:1]: The SPE #1 loopback enable bits (SPE1_LBEN[16:1]) control line loopback for tributaries #16 to #1 of SPE #1 of the SBI Interface. When SPE1_LBEN[n] is set high, the data on tributary #n output by the SBI PISO block is looped back to the tributary #n input of the SBI SIPO block. When SPE1_LBEN[n] is set low, transmit data for tributary #n is provided by the TCAS block (i.e. processed normally).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
82
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x034 : FREEDM-84A672 Master Tributary Loopback #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
SPE2_LBEN[4] SPE2_LBEN[3] SPE2_LBEN[2] SPE2_LBEN[1] SPE1_LBEN[28] SPE1_LBEN[27] SPE1_LBEN[26] SPE1_LBEN[25] SPE1_LBEN[24] SPE1_LBEN[23] SPE1_LBEN[22] SPE1_LBEN[21] SPE1_LBEN[20] SPE1_LBEN[19] SPE1_LBEN[18] SPE1_LBEN[17]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
This register controls line loopback for tributaries #17 to #28 of SPE #1 and tributaries #1 to #4 of SPE #2. SPE1_LBEN[28:17]: The SPE #1 loopback enable bits (SPE1_LBEN[28:17]) control line loopback for tributaries #28 to #17 of SPE #1 of the SBI Interface. When SPE1_LBEN[n] is set high, the data on tributary #n output by the SBI PISO block is looped back to the tributary #n input of the SBI SIPO block. When SPE1_LBEN[n] is set low, transmit data for tributary #n is provided by the TCAS block (i.e. processed normally). SPE2_LBEN[4:1]: The SPE #2 loopback enable bits (SPE2_LBEN[4:1]) control line loopback for tributaries #4 to #1 of SPE #2 of the SBI Interface. When SPE2_LBEN[n] is
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
83
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
set high, the data on tributary #n output by the SBI PISO block is looped back to the tributary #n input of the SBI SIPO block. When SPE2_LBEN[n] is set low, transmit data for tributary #n is provided by the TCAS block (i.e. processed normally).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
84
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x038 : FREEDM-84A672 Master Tributary Loopback #3 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
SPE2_LBEN[20] SPE2_LBEN[19] SPE2_LBEN[18] SPE2_LBEN[17] SPE2_LBEN[16] SPE2_LBEN[15] SPE2_LBEN[14] SPE2_LBEN[13] SPE2_LBEN[12] SPE2_LBEN[11] SPE2_LBEN[10] SPE2_LBEN[9] SPE2_LBEN[8] SPE2_LBEN[7] SPE2_LBEN[6] SPE2_LBEN[5]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
This register controls line loopback for tributaries #5 to #20 of SPE #2. SPE2_LBEN[20:5]: The SPE #2 loopback enable bits (SPE2_LBEN[20:5]) control line loopback for tributaries #20 to #5 of SPE #2 of the SBI Interface. When SPE2_LBEN[n] is set high, the data on tributary #n output by the SBI PISO block is looped back to the tributary #n input of the SBI SIPO block. When SPE2_LBEN[n] is set low, transmit data for tributary #n is provided by the TCAS block (i.e. processed normally).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
85
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x03C : FREEDM-84A672 Master Tributary Loopback #4 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
SPE3_LBEN[8] SPE3_LBEN[7] SPE3_LBEN[6] SPE3_LBEN[5] SPE3_LBEN[4] SPE3_LBEN[3] SPE3_LBEN[2] SPE3_LBEN[1] SPE2_LBEN[28] SPE2_LBEN[27] SPE2_LBEN[26] SPE2_LBEN[25] SPE2_LBEN[24] SPE2_LBEN[23] SPE2_LBEN[22] SPE2_LBEN[21]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
This register controls line loopback for tributaries #21 to #28 of SPE #2 and tributaries #1 to #8 of SPE #3. SPE3_LBEN[28:21]: The SPE #2 loopback enable bits (SPE2_LBEN[28:21]) control line loopback for tributaries #28 to #21 of SPE #2 of the SBI Interface. When SPE2_LBEN[n] is set high, the data on tributary #n output by the SBI PISO block is looped back to the tributary #n input of the SBI SIPO block. When SPE2_LBEN[n] is set low, transmit data for tributary #n is provided by the TCAS block (i.e. processed normally). SPE3_LBEN[8:1]: The SPE #3 loopback enable bits (SPE3_LBEN[8:1]) control line loopback for tributaries #8 to #1 of SPE #3 of the SBI Interface. When SPE3_LBEN[n] is
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
86
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
set high, the data on tributary #n output by the SBI PISO block is looped back to the tributary #n input of the SBI SIPO block. When SPE3_LBEN[n] is set low, transmit data for tributary #n is provided by the TCAS block (i.e. processed normally).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
87
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x040 : FREEDM-84A672 Master Tributary Loopback #5 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
SPE3_LBEN[24] SPE3_LBEN[23] SPE3_LBEN[22] SPE3_LBEN[21] SPE3_LBEN[20] SPE3_LBEN[19] SPE3_LBEN[18] SPE3_LBEN[17] SPE3_LBEN[16] SPE3_LBEN[15] SPE3_LBEN[14] SPE3_LBEN[13] SPE3_LBEN[12] SPE3_LBEN[11] SPE3_LBEN[10] SPE3_LBEN[9]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
This register controls line loopback for tributaries #9 to #24 of SPE #3. SPE3_LBEN[24:9]: The SPE #3 loopback enable bits (SPE3_LBEN[24:9]) control line loopback for tributaries #24 to #9 of SPE #3 of the SBI Interface. When SPE3_LBEN[n] is set high, the data on tributary #n output by the SBI PISO block is looped back to the tributary #n input of the SBI SIPO block. When SPE3_LBEN[n] is set low, transmit data for tributary #n is provided by the TCAS block (i.e. processed normally).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
88
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x044 : FREEDM-84A672 Master Tributary Loopback #6 Bit
Bit 15 to Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W
Type
Function
Unused
Default
X
SPE3_LBEN[28] SPE3_LBEN[27] SPE3_LBEN[26] SPE3_LBEN[25]
0 0 0 0
This register controls line loopback for tributaries #25 to #28 of SPE #3. SPE3_LBEN[28:25]: The SPE #3 loopback enable bits (SPE3_LBEN[28:25]) control line loopback for tributaries #28 to #25 of SPE #3 of the SBI Interface. When SPE3_LBEN[n] is set high, the data on tributary #n output by the SBI PISO block is looped back to the tributary #n input of the SBI SIPO block. When SPE3_LBEN[n] is set low, transmit data for tributary #n is provided by the TCAS block (i.e. processed normally).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
89
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x048 : FREEDM-84A672 SBI DROP BUS Master Configuration Bit
Bit 15 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
Function
Unused
Default
X
Reserved Reserved FCLK_FREQ[1] FCLK_FREQ[0] SPE3_TYP[1] SPE3_TYP[0] SPE2_TYP[1] SPE2_TYP[0] SPE1_TYP[1] SPE1_TYP[0]
0 0 0 0 0 0 0 0 0 0
This register controls configures the operation of the SBI DROP BUS. SPEn_TYP[1:0]: The SPE type bits (SPEn_TYP[1:0]) determine the configuration of each of the three Synchronous Payload Envelopes conveyed on the SBI DROP BUS, according to the following table.
Table 12 - SPE Type Configuration SPEn_TYP[1:0] 00 01 10 11
FCLK_FREQ[1:0]: The FASTCLK frequency selector bits (FCLK_FREQ[1:0]) must be set according to the following table, depending on the frequency chosen for the FASTCLK input.
Link Configuration 28 T1/J1 links 21 E1 links Single DS-3 link Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
90
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 13 - FASTCLK Frequency Selection FCLK_FREQ[1:0] 00 01 10 11
Reserved: The reserved bits must be set low for correct operation of the FREEDM84A672 device.
FASTCLK Frequency 51.84 MHz 44.928 MHz Reserved 66 MHz
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
91
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x04C : FREEDM-84A672 SBI ADD BUS Master Configuration Bit
Bit 15 to Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
Function
Unused
Default
X
PERM_DRV Reserved Reserved Reserved Reserved Reserved FCLK_FREQ[1] FCLK_FREQ[0] SPE3_TYP[1] SPE3_TYP[0] SPE2_TYP[1] SPE2_TYP[0] SPE1_TYP[1] SPE1_TYP[0]
0 0 0 0 0 0 0 0 0 0 0 0 0 0
This register controls configures the operation of the SBI ADD BUS. SPEn_TYP[1:0]: The SPE type bits (SPEn_TYP[1:0]) determine the configuration of each of the three Synchronous Payload Envelopes conveyed on the SBI ADD BUS, according to the following table.
Table 14 - SPE Type Configuration SPEn_TYP[1:0] 00 01 10 11 Link Configuration 28 T1/J1 links 21 E1 links Single DS-3 link Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
92
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
FCLK_FREQ[1:0]: The FASTCLK frequency selector bits (FCLK_FREQ[1:0]) must be set according to the following table, depending on the frequency chosen for the FASTCLK input.
Table 15 - FASTCLK Frequency Selection FCLK_FREQ[1:0] 00 01 10 11
Reserved: The reserved bits must be set low for correct operation of the FREEDM84A672 device. PERM_DRV: The Permanent Bus Driver selector bit (PERM_DRV) enables the FREEDM84A672 device to drive the SBI ADD BUS continously. When set to 1, the FREEDM-84A672 will drive the bus and assert the AACTIVE output at all times, provided that the ADETECT[1:0] inputs are both 0. When set to 0, the FREEDM-84A672 will only drive the bus and assert AACTIVE when it has data to send (and when ADETECT[1:0] are both 0). PERM_DRV should only be set to 1 if the FREEDM-84A672 is the only device driving the SBI ADD bus and it is desired to prevent the bus tristating.
FASTCLK Frequency 51.84 MHz 44.928 MHz Reserved 66 MHz
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
93
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x100 : RCAS Indirect Link and Time-slot Select Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R R/W
Function
BUSY RWB Unused LINK[6] LINK[5] LINK[4] LINK[3] LINK[2] LINK[1] LINK[0] Unused TSLOT[4] TSLOT[3] TSLOT[2] TSLOT[1] TSLOT[0]
Default
X 0 X 0 0 0 0 0 0 0 X 0 0 0 0 0
This register provides the receive link and time-slot number used to access the channel provision RAM. Writing to this register triggers an indirect register access. TSLOT[4:0]: The indirect time-slot number bits (TSLOT[4:0]) indicate the time-slot to be configured or interrogated in the indirect access. For a channelised T1/J1 link, time-slots 1 to 24 are valid. For a channelised E1 link, time-slots 1 to 31 are valid. For unchannelised or unframed links, only time-slot 0 is valid. LINK[6:0]: The indirect link number bits (LINK[6:0]) select amongst the 84 receive links to be configured or interrogated in the indirect access.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
94
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
RWB: The indirect access control bit (RWB) selects between a configure (write) or interrogate (read) access to the channel provision RAM. The address to the channel provision RAM is constructed by concatenating the TSLOT[4:0] and LINK[6:0] bits. Writing a logic zero to RWB triggers an indirect write operation. Data to be written is taken from the PROV, the CDLBEN and the CHAN[9:0] bits of the RCAS Indirect Channel Data register. Writing a logic one to RWB triggers an indirect read operation. Addressing of the RAM is the same as in an indirect write operation. The data read can be found in the PROV, the CDLBEN and the CHAN[9:0] bits of the RCAS Indirect Channel Data register. BUSY: The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set high when this register is written to trigger an indirect access, and will stay high until the access is complete. At which point, BUSY will be set low. This register should be polled to determine when data from an indirect read operation is available in the RCAS Indirect Channel Data register or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
95
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x104 : RCAS Indirect Channel Data Bit
Bit 15 Bit 14 Bit 13 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R/W R/W
Function
CDLBEN PROV Unused
Default
0 0 XH
CHAN[9] CHAN[8] CHAN[7] CHAN[6] CHAN[5] CHAN[4] CHAN[3] CHAN[2] CHAN[1] CHAN[0]
0 0 0 0 0 0 0 0 0 0
This register contains the data read from the channel provision RAM after an indirect read operation or the data to be inserted into the channel provision RAM in an indirect write operation. CHAN[9:0]: The indirect data bits (CHAN[9:0]) report the channel number read from the channel provision RAM after an indirect read operation has completed. Channel number to be written to the channel provision RAM in an indirect write operation must be set up in this register before triggering the write. CHAN[9:0] reflects the value written until the completion of a subsequent indirect read operation. PROV: The indirect provision enable bit (PROV) reports the channel provision enable flag read from the channel provision RAM after an indirect read operation has completed. The provision enable flag to be written to the channel provision RAM, in an indirect write operation, must be set up in this register before
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
96
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
triggering the write. When PROV is set high, the current receive data byte is processed as part of the channel as indicated by CHAN[9:0]. When PROV is set low, the current time-slot does not belong to any channel and the receive data byte ignored. PROV reflects the value written until the completion of a subsequent indirect read operation. CDLBEN: The indirect channel based diagnostic loopback enable bit (CDLBEN) reports the loopback enable flag read from channel provision RAM after an indirect read operation has complete. The loopback enable flag to be written to the channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. When CDLBEN is set high, the current receive data byte is to be over-written by data retrieved from the loopback FIFO of the channel as indicated by CHAN[9:0]. When CDLBEN is set low, the current receive data byte is processed normally. CDLBEN reflects the value written until the completion of a subsequent indirect read operation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
97
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x10C : RCAS Channel Disable Bit
Bit 15 Bit 14 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R/W
Function
CHDIS Unused
Default
0 XXH
DCHAN[9] DCHAN[8] DCHAN[7] DCHAN[6] DCHAN[5] DCHAN[4] DCHAN[3] DCHAN[2] DCHAN[1] DCHAN[0]
0 0 0 0 0 0 0 0 0 0
This register controls the disabling of one specific channel to allow orderly provisioning of time-slots associated with that channel. DCHAN[9:0]: The disable channel number bits (DCHAN[9:0]) selects the channel to be disabled. When CHDIS is set high, the channel specified by DCHAN[9:0] is disabled. Data in time-slots associated with the specified channel is ignored. When CHDIS is set low, the channel specified by DCHAN[9:0] operates normally. CHDIS: The channel disable bit (CHDIS) controls the disabling of the channels specified by DCHAN[9:0]. When CHDIS is set high, the channel selected by DCHAN[9:0] is disabled. Data in time-slots associated with the specified channel is ignored. When CHDIS is set low, the channel specified by DCHAN[9:0] operates normally.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
98
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x140 : RCAS SBI SPE1 Configuration Register #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[11] FEN[10] FEN[9] FEN[8] FEN[7] FEN[6] FEN[5] FEN[4] FEN[3] FEN[2] FEN[1] FEN[0] Unused SBI_MODE[2] SBI_MODE[1] SBI_MODE[0]
Default
0 0 0 0 0 0 0 0 0 0 0 0 X 0 0 0
This register configures the operational mode of receive links 0, 3, 6, 9, ... 33, 36, 39, ...81, i.e. those links mapped to SPE 1 of the SBI DROP BUS. SBI_MODE[2:0]: The SBI mode select bits (SBI_MODE[2:0]) configure the receive links of SPE1, as shown in the following table:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
99
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 16 - SBI Mode SPE1 Configuration SBI_MODE [2:0] 000 001 010 011 100 101 110 111
FEN[11:0] Each FEN bit, FEN[n], configures link 3n for framed operation. In unframed operation (FEN[n] = 0), all framing bit locations are treated as containing data. In framed mode (FEN[n] = 1), the contents of framing bit locations are ignored.
SPE1 Configuration Single unchannelised DS-3 on link 0 28 T1/J1 links 21 E1 links (links 63, 66, 69, ... , 81 are unused) Reserved Reserved Reserved Reserved Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
100
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x144 : RCAS SBI SPE1 Configuration Register #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[27] FEN[26] FEN[25] FEN[24] FEN[23] FEN[22] FEN[21] FEN[20] FEN[19] FEN[18] FEN[17] FEN[16] FEN[15] FEN[14] FEN[13] FEN[12]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The bits of this register set are used to configure the framing modes of receive links 36, 39, 42 ... 81. FEN[27:12]: Each FEN bit, FEN[n], configures link 3n for framed operation. In unframed operation (FEN[n] = 0), all framing bit locations are treated as containing data. In framed mode (FEN[n] = 1), the contents of framing bit locations are ignored.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
101
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x148 : RCAS SBI SPE2 Configuration Register #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[11] FEN[10] FEN[9] FEN[8] FEN[7] FEN[6] FEN[5] FEN[4] FEN[3] FEN[2] FEN[1] FEN[0] Unused SBI_MODE[2] SBI_MODE[1] SBI_MODE[0]
Default
0 0 0 0 0 0 0 0 0 0 0 0 X 0 0 0
This register configures the operational mode of receive links 1, 4, 7, 10, ... 34, 37, ...82, i.e. those links mapped to SPE 2 of the SBI DROP BUS. SBI_MODE[2:0]: The SBI mode select bits (SBI_MODE[2:0]) configure the receive links of SPE2, as shown in the following table:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
102
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 17 - SBI Mode SPE2 Configuration SBI_MODE [2:0] 000 001 010 011 100 101 110 111
FEN[11:0] Each FEN bit, FEN[n], configures link 3n+1 for framed operation. In unframed operation (FEN[n] = 0), all framing bit locations are treated as containing data. In framed mode (FEN[n] = 1), the contents of framing bit locations are ignored.
SPE2 Configuration Single unchannelised DS-3 on link 1 28 T1/J1 links 21 E1 links (links 64, 67, 70, ... , 82 are unused) Reserved Reserved Reserved Reserved Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
103
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x14C : RCAS SBI SPE2 Configuration Register #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[27] FEN[26] FEN[25] FEN[24] FEN[23] FEN[22] FEN[21] FEN[20] FEN[19] FEN[18] FEN[17] FEN[16] FEN[15] FEN[14] FEN[13] FEN[12]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The bits of this register set are used to configure the framing modes of receive links 37, 40, 43 ... 82. FEN[27:12]: Each FEN bit, FEN[n], configures link 3n+1 for framed operation. In unframed operation (FEN[n] = 0), all framing bit locations are treated as containing data. In framed mode (FEN[n] = 1), the contents of framing bit locations are ignored.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
104
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x150 : RCAS SBI SPE3 Configuration Register #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[11] FEN[10] FEN[9] FEN[8] FEN[7] FEN[6] FEN[5] FEN[4] FEN[3] FEN[2] FEN[1] FEN[0] Unused SBI_MODE[2] SBI_MODE[1] SBI_MODE[0]
Default
0 0 0 0 0 0 0 0 0 0 0 0 X 0 0 0
This register configures the operational mode of receive links 2, 5, 8, 11, ... 35, 38, ...83, i.e. those links mapped to SPE 3 of the SBI DROP BUS. SBI_MODE[2:0]: The SBI mode select bits (SBI_MODE[2:0]) configure the receive links of SPE3, as shown in the following table:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
105
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 18 - SBI Mode SPE3 Configuration SBI_MODE [2:0] 000 001 010 011 100 101 110 111
FEN[11:0] Each FEN bit, FEN[n], configures link 3n+2 for framed operation. In unframed operation (FEN[n] = 0), all framing bit locations are treated as containing data. In framed mode (FEN[n] = 1), the contents of framing bit locations are ignored.
SPE3 Configuration Single unchannelised DS-3 on link 2 28 T1/J1 links 21 E1 links (links 65, 68, 71, ... , 83 are unused) Reserved Reserved Reserved Reserved Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
106
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x154 : RCAS SBI SPE3 Configuration Register #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[27] FEN[26] FEN[25] FEN[24] FEN[23] FEN[22] FEN[21] FEN[20] FEN[19] FEN[18] FEN[17] FEN[16] FEN[15] FEN[14] FEN[13] FEN[12]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The bits of this register set are used to configure the framing modes of receive links 38, 41, 44 ... 83. FEN[27:12]: Each FEN bit, FEN[n], configures link 3n+2 for framed operation. In unframed operation (FEN[n] = 0), all framing bit locations are treated as containing data. In framed mode (FEN[n] = 1), the contents of framing bit locations are ignored.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
107
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x180 - 0x188 : RCAS Links #0 to #2 Configuration Bit
Bit 15 to Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W
Type
Function
Unused
Default
XXXH
Reserved Unused Reserved Reserved Reserved
0 X 0 0 0
This register controls the operation of receive links #0 to #2 when they are configured to receive data from the RD[2:0] inputs (i.e. SPEn_EN is low). Reserved: The reserved bits must be set low for correct operation of the FREEDM84A672 device.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
108
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x200 : RHDL Indirect Channel Select Bit
Bit 15 Bit 14 Bit 13 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R R/W
Function
BUSY CRWB Unused
Default
X 0 XH
CHAN[9] CHAN[8] CHAN[7] CHAN[6] CHAN[5] CHAN[4] CHAN[3] CHAN[2] CHAN[1] CHAN[0]
0 0 0 0 0 0 0 0 0 0
This register provides the channel number used to access the receive channel provision RAM. Writing to this register triggers an indirect channel register access. CHAN[9:0]: The indirect channel number bits (CHAN[9:0]) indicate the receive channel to be configured or interrogated in the indirect access. CRWB: The channel indirect access control bit (CRWB) selects between a configure (write) or interrogate (read) access to the receive channel provision RAM. Writing a logic zero to CRWB triggers an indirect write operation. Data to be written is taken from the Indirect Channel Data registers. Writing a logic one to CRWB triggers an indirect read operation. The data read can be found in the Indirect Channel Data registers.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
109
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
BUSY: The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set high when this register is written to trigger an indirect access, and will stay high until the access is complete. At which point, BUSY will be set low. This register should be polled to determine when data from an indirect read operation is available in the RHDL Indirect Channel Data #1 and #2 registers or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
110
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x204 : RHDL Indirect Channel Data Register #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R W W W W W W W W W W W W
Function
PROV STRIP DELIN TAVAIL Reserved FPTR[10] FPTR[9] FPTR[8] FPTR[7] FPTR[6] FPTR[5] FPTR[4] FPTR[3] FPTR[2] FPTR[1] FPTR[0]
Default
0 0 0 X X X X X X X X X X X X X
This register contains data read from the channel provision RAM after an indirect read operation or data to be inserted into the channel provision RAM in an indirect write operation. FPTR[10:0]: The indirect FIFO block pointer (FPTR[10:0]) identifies one of the blocks of the circular linked list in the partial packet buffer used in the logical FIFO of the current channel. The FIFO pointer to be written to the channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. The FIFO pointer value can be any one of the blocks provisioned to form the circular buffer.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
111
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device. TAVAIL: The indirect transaction available bit (TAVAIL) reports the fill level of the partial packet buffer used in the logical FIFO of the current channel. TAVAIL is set high when the FIFO of the current channel contains sufficient data, as controlled by XFER[3:0], to result in a transfer across the receive APPI. TAVAIL is set low when the amount of receive data is too small to result in a transfer across the receive APPI. TAVAIL is updated by an indirect channel read operation. DELIN: The indirect delineate enable bit (DELIN) configures the HDLC processor to perform flag sequence delineation and bit de-stuffing on the incoming data stream. The delineate enable bit to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. When DELIN is set high, flag sequence delineation and bit de-stuffing is performed on the incoming data stream. When DELIN is set low, the HDLC processor does not perform any processing (flag sequence delineation, bit de-stuffing nor CRC verification) on the incoming stream. DELIN reflects the value written until the completion of a subsequent indirect channel read operation. STRIP: The indirect frame check sequence discard bit (STRIP) configures the HDLC processor to remove the CRC from the incoming frame when writing the data to the channel FIFO. The FCS discard bit to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. When STRIP is set high and CRC[1:0] is not equal to "00", the received CRC value is not written to the FIFO. When STRIP is set low, the received CRC value is written to the FIFO. The bytes in buffer field of the RPD correctly reflect the presence/absence of CRC bytes in the buffer. The value of STRIP is ignored when DELIN is low. STRIP reflects the value written until the completion of a subsequent indirect channel read operation. PROV: The indirect provision enable bit (PROV) reports the channel provision enable flag read from the channel provision RAM after an indirect channel read operation has completed. The provision enable flag to be written to the
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
112
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. When PROV is set high, the HDLC processor will process data on the channel specified by CHAN[9:0]. When PROV is set low, the HDLC processor will ignore data on the channel specified by CHAN[9:0]. PROV reflects the value written until the completion of a subsequent indirect channel read operation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
113
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x208 : RHDL Indirect Channel Data Register #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W
Type
R/W R/W R/W
Function
7BIT PRIORITY INVERT Unused CRC[1] CRC[0] OFFSET[1] OFFSET[0] Unused Unused Unused Unused XFER[3] XFER[2] XFER[1] XFER[0]
Default
0 0 0 X 0 0 0 0 X X X X 0 0 0 0
This register contains data read from the channel provision RAM after an indirect read operation or data to be inserted into the channel provision RAM in an indirect write operation. XFER[3:0]: The indirect channel transfer size (XFER[3:0]) configures the amount of data transferred in each transaction. The channel transfer size to be written to the channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. When the channel FIFO depth reaches the depth specified by XFER[3:0] or when an end-of-packet exists in the FIFO, a poll of this FREEDM-84A672 device will indicate that data exists and is ready to be transferred across the receive APPI. Channel transfer size is measured in 16 byte blocks. The amount of data transferred and the depth threshold are specified by given setting is:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
114
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
XFER[3:0] + 1 blocks = 16 * (XFER[3:0] + 1) bytes XFER[3:0] should be set such that the number of blocks transferred is at least two fewer than the total allocated to the associated channel. XFER[3:0] reflects the value written until the completion of a subsequent indirect channel read operation. OFFSET[1:0]: The packet byte offset (OFFSET[1:0]) configures the partial packet processor to insert invalid bytes at the beginning of a packet stored in the channel FIFO. The value of OFFSET[1:0] to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. The number of bytes inserted before the beginning of a HDLC packet is defined by the binary value of OFFSET[1:0]. OFFSET[1:0] reflects the value written until the completion of a subsequent indirect channel read operation. CRC[1:0]: The CRC algorithm bits (CRC[1:0]) configures the HDLC processor to perform CRC verification on the incoming data stream. The value of CRC[1:0] to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. CRC[1:0] is ignored when DELIN is low. CRC[1:0] reflects the value written until the completion of a subsequent indirect channel read operation.
Table 19 - CRC[1:0] Settings CRC[1]
0 0 1 1 INVERT: The HDLC data inversion bit (INVERT) configures the HDLC processor to logically invert the incoming HDLC stream from the RCAS672 before processing it. The value of INVERT to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. When INVERT is set to one, the HDLC stream is logically inverted before processing. When INVERT is set to zero, the HDLC
CRC[0]
0 1 0 1
Operation
No Verification CRC-CCITT CRC-32 Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
115
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
stream is not inverted before processing. INVERT reflects the value written until the completion of a subsequent indirect channel read operation. PRIORITY: The channel FIFO priority bit (PRIORITY) informs the partial packet processor that the channel has precedence over other channels when being serviced by the RAPI672 block for transfer across the receive APPI. The value of PRIORITY to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. Channel FIFOs with PRIORITY set to one are serviced by the RAPI672 before channel FIFOs with PRIORITY set to zero. Channels with an HDLC data rate to FIFO size ratio that is significantly higher than other channels should have PRIORITY set to one. PRIORITY reflects the value written until the completion of a subsequent indirect channel read operation. 7BIT: The 7BIT enable bit (7BIT) configures the HDLC processor to ignore the least significant bit of each octet in the incoming channel stream. The value of 7BIT to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. When 7BIT is set high, the least significant bit (last bit of each octet received), is ignored. When 7BIT is set low, the entire receive data stream is processed. 7BIT reflects the value written until the completion of a subsequent indirect channel read operation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
116
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x210 : RHDL Indirect Block Select Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R R/W
Function
BUSY BRWB Unused Unused Reserved BLOCK[10] BLOCK[9] BLOCK[8] BLOCK[7] BLOCK[6] BLOCK[5] BLOCK[4] BLOCK[3] BLOCK[2] BLOCK[1] BLOCK[0]
Default
X X X X X X X X X X X X X X X X
This register provides the block number used to access the block pointer RAM. Writing to this register triggers an indirect block register access. BLOCK[10:0]: The indirect block number (BLOCK[10:0]) indicate the block to be configured or interrogated in the indirect access. Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device. BRWB: The block indirect access control bit (BRWB) selects between a configure (write) or interrogate (read) access to the block pointer RAM. Writing a logic
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
117
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
zero to BRWB triggers an indirect block write operation. Data to be written is taken from the Indirect Block Data register. Writing a logic one to BRWB triggers an indirect block read operation. The data read can be found in the Indirect Block Data register. BUSY: The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set high when this register is written to trigger an indirect access, and will stay high until the access is complete. At which point, BUSY will be set low. This register should be polled to determine when data from an indirect read operation is available in the RHDL Indirect Block Data register or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
118
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x214 : RHDL Indirect Block Data Bit
Bit 15 to Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
Function
Unused
Default
XH
Reserved BPTR[10] BPTR[9] BPTR[8] BPTR[7] BPTR[6] BPTR[5] BPTR[4] BPTR[3] BPTR[2] BPTR[1] BPTR[0]
X 0 0 0 0 0 0 0 0 0 0 0
This register contains data read from the block pointer RAM after an indirect block read operation or data to be inserted into the block pointer RAM in an indirect block write operation. BPTR[10:0]: The indirect block pointer (BPTR[10:0]) configures the block pointer of the block specified by the Indirect Block Select register. The block pointer to be written to the block pointer RAM, in an indirect write operation, must be set up in this register before triggering the write. The block pointer value is the block number of the next block in the linked list. A circular list of blocks must be formed in order to use the block list as a receive channel FIFO buffer. BPTR[10:0] reflects the value written until the completion of a subsequent indirect block read operation. When provisioning a channel FIFO, all block pointers must be re-written to properly initialize the FIFO.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
119
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
120
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x220 : RHDL Configuration Bit
Bit 15 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W
Type
Function
Unused
Default
XXH
LENCHK TSTD Unused Unused Unused Unused Unused Unused Unused Unused
0 0 X X X X X X X X
This register configures all provisioned receive channels. TSTD: The telecom standard bit (TSTD) controls the bit ordering of the HDLC data transferred across the receive APPI. When TSTD is set low, the least significant bit of each byte on the receive APPI bus (AD[0] and AD[8]) is the first HDLC bit received and the most significant bit of each byte (AD[7] and AD[15]) is the last HDLC bit received (datacom standard). When TSTD is set high, AD[0] and AD[8] are the last HDLC bits received and AD[7] and AD[15] are the first HDLC bits received (telecom standard). LENCHK: The packet length error check bit (LENCHK) controls the checking of receive packets that are longer than the maximum programmed length. When LENCHK is set high, receive packets are aborted and the remainder of the frame discarded when the packet exceeds the maximum packet length given by MAX[15:0]. When LENCHK is set low, receive packets are not checked for maximum size and MAX[15:0] must be set to `hFFFF.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
121
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x224 : RHDL Maximum Packet Length Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
MAX[15] MAX[14] MAX[13] MAX[12] MAX[11] MAX[10] MAX[9] MAX[8] MAX[7] MAX[6] MAX[5] MAX[4] MAX[3] MAX[2] MAX[1] MAX[0]
Default
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
This register configures the maximum legal HDLC packet byte length. MAX[15:0]: The maximum HDLC packet length (MAX[15:0]) configures the FREEDM84A672 to reject HDLC packets longer than a maximum size when LENCHK is set high. Receive packets with total length, including address, control, information and FCS fields, greater than MAX[15:0] bytes are aborted. When LENCHK is set low, aborts are not generated regardless of packet length and MAX[15:0] must be set to `hFFFF.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
122
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x380 : THDL Indirect Channel Select Bit
Bit 15 Bit 14 Bit 13 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R R/W
Function
BUSY CRWB Unused
Default
X 0 XH
CHAN[9] CHAN[8] CHAN[7] CHAN[6] CHAN[5] CHAN[4] CHAN[3] CHAN[2] CHAN[1] CHAN[0]
0 0 0 0 0 0 0 0 0 0
This register provides the channel number used to access the transmit channel provision RAM. Writing to this register triggers an indirect channel register access. CHAN[9:0]: The indirect channel number bits (CHAN[9:0]) indicate the channel to be configured or interrogated in the indirect access. CRWB: The channel indirect access control bit (CRWB) selects between a configure (write) or interrogate (read) access to the channel provision RAM. Writing a logic zero to CRWB triggers an indirect write operation. Data to be written is taken from the Indirect Channel Data registers. Writing a logic one to CRWB triggers an indirect read operation. The data read can be found in the Indirect Channel Data registers.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
123
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
BUSY: The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set high when this register is written to trigger an indirect access, and will stay high until the access is complete. At which point, BUSY will be set low. This register should be polled to determine when data from an indirect read operation is available in the THDL Indirect Channel Data #1, #2 and #3 registers or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
124
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x384 : THDL Indirect Channel Data #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W W W W W W W W W W W W W
Function
PROV CRC[1] CRC[0] DELIN Reserved FPTR[10] FPTR[9] FPTR[8] FPTR[7] FPTR[6] FPTR[5] FPTR[4] FPTR[3] FPTR[2] FPTR[1] FPTR[0]
Default
0 0 0 0 X 0 0 0 0 0 0 0 0 0 0 0
This register contains data read from the channel provision RAM after an indirect channel read operation or data to be inserted into the channel provision RAM in an indirect channel write operation. FPTR[10:0]: The indirect FIFO block pointer (FPTR[10:0]) informs the partial packet buffer processor about the circular linked list of blocks to use for a FIFO for the channel. The FIFO pointer to be written to the channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. The FIFO pointer value can be any one of the block numbers provisioned, by indirect block write operations, to form the circular buffer.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
125
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device. DELIN: The indirect delineate enable bit (DELIN) configures the HDLC processor to perform flag sequence insertion and bit stuffing on the outgoing data stream. The delineate enable bit to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. When DELIN is set high, flag sequence insertion, bit stuffing and ,optionally, CRC generation is performed on the outgoing HDLC data stream. When DELIN is set low, the HDLC processor does not perform any processing (flag sequence insertion, bit stuffing nor CRC generation) on the outgoing stream. DELIN reflects the value written until the completion of a subsequent indirect channel read operation. CRC[1:0]: The CRC algorithm (CRC[1:0]) configures the HDLC processor to perform CRC generation on the outgoing HDLC data stream. The value of CRC[1:0] to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. CRC[1:0] is ignored when DELIN is low. CRC[1:0] reflects the value written until the completion of a subsequent indirect channel read operation.
Table 20 - CRC[1:0] Settings CRC[1]
0 0 1 1 PROV: The indirect provision enable bit (PROV) reports the channel provision enable flag read from the channel provision RAM after an indirect channel read operation has completed. The provision enable flag to be written to the channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. When PROV is set high, the HDLC processor will service requests for data from the TCAS672 block. When PROV is set low, the HDLC processor will ignore requests from the TCAS672
CRC[0]
0 1 0 1
Operation
No CRC CRC-CCITT CRC-32 Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
126
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
block. PROV reflects the value written until the completion of a subsequent indirect channel read operation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
127
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x388 : THDL Indirect Channel Data #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W W W W W W W W W W W W W
Function
7BIT Reserved INVERT DFCS Reserved FLEN[10] FLEN[9] FLEN[8] FLEN[7] FLEN[6] FLEN[5] FLEN[4] FLEN[3] FLEN[2] FLEN[1] FLEN[0]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
This register contains data to be inserted into the channel provision RAM in an indirect write operation. FLEN[10:0]: The indirect FIFO length (FLEN[10:0]) is the number of blocks, less one, that is provisioned to the circular channel FIFO specified by the FPTR[10:0] block pointer. The FIFO length to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. Reserved: The reserved bits must be set low for correct operation of the FREEDM84A672 device.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
128
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
DFCS: The diagnose frame check sequence bit (DFCS) controls the inversion of the FCS field inserted into the transmit packet. The value of DFCS to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. When DFCS is set to one, the FCS field in the outgoing HDLC stream is logically inverted allowing diagnosis of downstream FCS verification logic. The outgoing FCS field is not inverted when DFCS is set to zero. DFCS reflects the value written until the completion of a subsequent indirect channel read operation. INVERT: The HDLC data inversion bit (INVERT) configures the HDLC processor to logically invert the outgoing HDLC stream. The value of INVERT to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. When INVERT is set to one, the outgoing HDLC stream is logically inverted. The outgoing HDLC stream is not inverted when INVERT is set to zero. INVERT reflects the value written until the completion of a subsequent indirect channel read operation. 7BIT: The least significant stuff enable bit (7BIT) configures the HDLC processor to stuff the least significant bit of each octet in the outgoing channel stream. The value of 7BIT to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. When 7BIT is set high, the least significant bit (last bit of each octet transmitted) does not contain channel data and is forced to the value configured by the BIT8 register bit. When 7BIT is set low, the entire octet contains valid data and BIT8 is ignored. 7BIT reflects the value written until the completion of a subsequent indirect channel read operation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
129
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x38C : THDL Indirect Channel Data #3 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R/W R/W
Function
TRANS IDLE Unused Unused LEVEL[3] LEVEL[2] LEVEL[1] LEVEL[0] FLAG[2] FLAG[1] FLAG[0] Unused XFER[3] XFER[2] XFER[1] XFER[0]
Default
0 0 X X 0 0 0 0 0 0 0 X 0 0 0 0
This register contains data read from the channel provision RAM after an indirect read operation or data to be inserted into the channel provision RAM in an indirect write operation. XFER[3:0]: The indirect channel transfer size (XFER[3:0]) specifies the amount of data the partial packet processor requests from the TAPI672 block. The channel transfer size to be written to the channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. When the channel FIFO free space reaches or exceeds the limit specified by XFER[3:0], the partial packet processor will inform the TAPI672 so that a poll on that channel reflects that the channel FIFO is able to accept XFER[3:0] + 1 blocks of data. FIFO free space and transfer size are measured in number of 16-byte blocks. XFER[3:0] reflects the value written until the completion of a subsequent indirect channel read operation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
130
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
To prevent lockup, the channel transfer size (XFER[3:0]) can be configured to be less than or equal to the start transmission level set by LEVEL[3:0] and TRANS. Alternatively, the channel transfer size can be set such that the total number of blocks in the logical channel FIFO minus the start transmission level is an integer multiple of the channel transfer size. FLAG[2:0]: The flag insertion control (FLAG[2:0]) configures the minimum number of flags or bytes of idle bits the HDLC processor inserts between HDLC packets. The value of FLAG[2:0] to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. The minimum number of flags or bytes of idle (8 bits of 1's) inserted between HDLC packets is shown in the table below. FLAG[2:0] reflects the value written until the completion of a subsequent indirect channel read operation.
Table 21 - FLAG[2:0] Settings FLAG[2:0]
000 001 010 011 100 101 110 111 LEVEL[3:0]: The indirect channel FIFO trigger level (LEVEL[3:0]), in concert with the TRANS bit, configure the various channel FIFO free space levels which trigger the HDLC processor to start transmission of a HDLC packet as well as trigger the partial packet buffer to request data from the TAPI672 as shown in the following table. The channel FIFO trigger level to be written to the channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. LEVEL[3:0] reflects the value written until the completion of a subsequent indirect channel read operation.
Minimum Number of Flag/Idle Bytes
1 flag / 0 Idle byte 2 flags / 0 idle byte 4 flags / 2 idle bytes 8 flags / 6 idle bytes 16 flags / 14 idle bytes 32 flags / 30 idle bytes 64 flags / 62 idle bytes 128 flags / 126 idle bytes
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
131
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
The HDLC processor starts transmitting a packet when the channel FIFO free space is less than or equal to the level specified in the appropriate Start Transmission Level column of the following table or when an end of a packet is stored in the channel FIFO. When the channel FIFO free space is greater than or equal to the level specified in the Starving Trigger Level column of the following table and the HDLC processor is transmitting a packet and an end of a packet is not stored in the channel FIFO, the partial packet buffer makes expedited requests to the TAPI672 to retrieve XFER[3:0] + 1 blocks of data. To prevent lockup, the channel transfer size (XFER[3:0]) can be configured to be less than or equal to the start transmission level set by LEVEL[3:0] and TRANS. Alternatively, the channel transfer size can be set such that the total number of blocks in the logical channel FIFO, minus the start transmission level, is an integer multiple of the channel transfer size. The starving trigger level must always be set to a number of blocks greater than or equal to the channel transfer size. IDLE: The interframe time fill bit (IDLE) configures the HDLC processor to use flag bytes or HDLC idle as the interframe time fill between HDLC packets. The value of IDLE to be written to the channel provision RAM, in an indirect channel write operation, must be set up in this register before triggering the write. When IDLE is set low, the HDLC processor uses flag bytes as the interframe time fill. When IDLE is set high, the HDLC processor uses HDLC idle (all one's bit with no bit-stuffing pattern is transmitted) as the interframe time fill. IDLE reflects the value written until the completion of a subsequent indirect channel read operation. TRANS: The indirect transmission start bit (TRANS), in concert with the LEVEL[3:0] bits, configure the various channel FIFO free space levels which trigger the HDLC processor to start transmission of a HDLC packet as well as trigger the partial packet buffer to request data from the TAPI672 as shown in the following table. The transmission start mode to be written to the channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. TRANS reflects the value written until the completion of a subsequent indirect channel read operation. The HDLC processor starts transmitting a packet when the channel FIFO free space is less than or equal to the level specified in the appropriate Start Transmission Level column of the following table or when an end of a packet is stored in the channel FIFO. When the channel FIFO free space is greater than or equal to the level specified in the Starving Trigger Level column of the
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
132
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
following table and the HDLC processor is transmitting a packet and an end of a packet is not stored in the channel FIFO, the partial packet buffer makes expedited requests to the TAPI672 to retrieve XFER[3:0] + 1 blocks of data. To prevent lockup, the channel transfer size (XFER[3:0]) can be configured to be less than or equal to the start transmission level set by LEVEL[3:0] and TRANS. Alternatively, the channel transfer size can be set, such that, the total number of blocks in the logical channel FIFO minus the start transmission level is an integer multiple of the channel transfer size. The starving trigger level must always be set to a number of blocks greater than or equal to the channel transfer size.
Table 22 - Level[3:0]/TRANS Settings LEVEL[3:0] Starving Trigger Level
2 Blocks (32 bytes free) 3 Blocks (48 bytes free) 4 Blocks (64 bytes free) 6 Blocks (96 bytes free) 8 Blocks (128 bytes free) 12 Blocks (192 bytes free) 16 Blocks (256 bytes free) 24 Blocks (384 bytes free) 32 Blocks (512 bytes free) 48 Blocks (768 bytes free)
Start Transmission Level (TRANS=0)
1 Block (16 bytes free) 2 Blocks (32 bytes free) 3 Blocks (48 bytes free) 4 Blocks (64 bytes free) 6 Blocks (96 bytes free) 8 Blocks (128 bytes free) 12 Blocks (192 bytes free) 16 Blocks (256 bytes free) 24 Blocks (384 bytes free) 32 Blocks (512 bytes free)
Start Transmission Level (TRANS=1)
1 Block (16 bytes free) 1 Block (16 bytes free) 2 Blocks (32 bytes free) 3 Blocks (48 bytes free) 4 Blocks (64 bytes free) 6 Blocks (96 bytes free) 8 Blocks (128 bytes free) 12 Blocks (192 bytes free) 16 Blocks (256 bytes free) 24 Blocks (384 bytes free)
0000 0001 0010 0011 0100 0101 0110 0111 1000 1001
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
133
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
LEVEL[3:0]
Starving Trigger Level
64 Blocks (1 Kbytes free) 96 Blocks (1.5 Kbytes free) 192 Blocks (3 Kbytes free) 384 Blocks (6 Kbytes free) 768 Blocks (12 Kbytes free) 1536 Blocks (24 Kbytes free)
Start Transmission Level (TRANS=0)
48 Blocks (768 bytes free) 64 Blocks (1 Kbytes free) 128 Blocks (2 Kbytes free) 256 Blocks (4 Kbytes free) 512 Blocks (8 Kbytes free) 1024 Blocks (16 Kbytes free)
Start Transmission Level (TRANS=1)
32 Blocks (512 bytes free) 48 Blocks (768 bytes free) 96 Blocks (1.5 Kbytes free) 192 Blocks (2 Kbytes free) 384 Blocks (4 Kbytes free) 768 Blocks (8 Kbytes free)
1010 1011 1100 1101 1110 1111
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
134
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x3A0 : THDL Indirect Block Select Bit
Bit 15 Bit 14 Bit 13 to Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R R/W
Function
BUSY BRWB Unused
Default
X 0 XH
Reserved BLOCK[10] BLOCK[9] BLOCK[8] BLOCK[7] BLOCK[6] BLOCK[5] BLOCK[4] BLOCK[3] BLOCK[2] BLOCK[1] BLOCK[0]
X 0 0 0 0 0 0 0 0 0 0 0
This register provides the block number used to access the block pointer RAM. Writing to this register triggers an indirect block register access. BLOCK[10:0]: The indirect block number (BLOCK[10:0]) indicate the block to be configured or interrogated in the indirect access. Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device. BRWB: The block indirect access control bit (BRWB) selects between a configure (write) or interrogate (read) access to the block pointer RAM. Writing a logic
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
135
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
zero to BRWB triggers an indirect block write operation. Data to be written is taken from the Indirect Block Data register. Writing a logic one to BRWB triggers an indirect block read operation. The data read can be found in the Indirect Block Data register. BUSY: The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set high when this register is written to trigger an indirect access, and will stay high until the access is complete. At which point, BUSY will be set low. This register should be polled to determine when data from an indirect read operation is available in the THDL Indirect Block Data register or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
136
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x3A4 : THDL Indirect Block Data Bit
Bit 15 Bit 14 to Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R/W
Function
Reserved Unused
Default
0 XH
Reserved BPTR[10] BPTR[9] BPTR[8] BPTR[7] BPTR[6] BPTR[5] BPTR[4] BPTR[3] BPTR[2] BPTR[1] BPTR[0]
X 0 0 0 0 0 0 0 0 0 0 0
This register contains data read from the transmit block pointer RAM after an indirect block read operation or data to be inserted into the transmit block pointer RAM in an indirect block write operation. BPTR[10:0]: The indirect block pointer (BPTR[10:0]) configures the block pointer of the block specified by the Indirect Block Select register. The block pointer to be written to the transmit block pointer RAM, in an indirect write operation, must be set up in this register before triggering the write. The block pointer value is the block number of the next block in the linked list. A circular list of blocks must be formed in order to use the block list as a channel FIFO buffer. FPTR[10:0] reflects the value written until the completion of a subsequent indirect block read operation. When provisioning a channel FIFO, all blocks pointers must be re-written to properly initialize the FIFO.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
137
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Reserved: The reserved bits (Reserved) must be set low for correct operation of the FREEDM-84A672 device.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
138
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x3B0 : THDL Configuration Bit
Bit 15 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 to Bit 4 Bit 3 to Bit 0 R/W R/W R/W R/W
Type
Function
Unused
Default
XXH
BIT8 TSTD Reserved Unused
0 0 0 XH
Reserved
0H
This register configures all provisioned channels. Reserved: The reserved bits must be set low for correct operation of the FREEDM84A672 device. TSTD: The telecom standard bit (TSTD) controls the bit ordering of the HDLC data transferred on the transmit APPI. When TSTD is set low, the least significant bit of the each byte on the transmit APPI bus (AD[0] and AD[8]) is the first HDLC bit transmitted and the most significant bit of each byte (AD[7] and AD[15]) is the last HDLC bit transmitted (datacom standard). When TSTD is set high, AD[0] and AD[8] are the last HDLC bit transmitted and AD[7] and AD[15] are the first HDLC bit transmitted (telecom standard). BIT8: The least significant stuff control bit (BIT8) carries the value placed in the least significant bit of each octet when the HDLC processor is configured (7BIT set high) to stuff the least significant bit of each octet in the corresponding transmit link (TD[n]). When BIT8 is set high, the least significant bit (last bit of each octet transmitted) is forced high. When BIT8 is set low, the least significant bit is forced low. BIT8 is ignored when 7BIT is set low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
139
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x400 : TCAS Indirect Link and Time-slot Select Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R R/W
Function
BUSY RWB Unused LINK[6] LINK[5] LINK[4] LINK[3] LINK[2] LINK[1] LINK[0] Unused TSLOT[4] TSLOT[3] TSLOT[2] TSLOT[1] TSLOT[0]
Default
X 0 X 0 0 0 0 0 0 0 X 0 0 0 0 0
This register provides the link number and time-slot number used to access the transmit channel provision RAM. Writing to this register triggers an indirect register access and transfers the contents of the Indirect Channel Data register to an internal holding register. TSLOT[4:0]: The indirect time-slot number bits (TSLOT[4:0]) indicate the time-slot to be configured or interrogated in the indirect access. For a channelised T1/J1 link, time-slots 1 to 24 are valid. For a channelised E1 link, time-slots 1 to 31 are valid. For unchannelised or unframed links, only time-slot 0 is valid. LINK[6:0]: The indirect link number bits (LINK[6:0]) select amongst the 84 transmit links to be configured or interrogated in the indirect access.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
140
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
RWB: The indirect access control bit (RWB) selects between a configure (write) or interrogate (read) access to the transmit channel provision RAM. The address to the transmit channel provision RAM is constructed by concatenating the TSLOT[6:0] and LINK[4:0] bits. Writing a logic zero to RWB triggers an indirect write operation. Data to be written is taken from the PROV and the CHAN[9:0] bits of the Indirect Data register. Writing a logic one to RWB triggers an indirect read operation. Addressing of the RAM is the same as in an indirect write operation. The data read can be found in the PROV and the CHAN[9:0] bits of the Indirect Channel Data register. BUSY: The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set high when this register is written to trigger an indirect access, and will stay high until the access is complete. At which point, BUSY will be set low. This register should be polled to determine when data from an indirect read operation is available in the TCAS Indirect Channel Data register or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
141
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x404 : TCAS Indirect Channel Data Bit
Bit 15 Bit 14 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R/W
Function
PROV Unused
Default
0 XXH
CHAN[9] CHAN[8] CHAN[7] CHAN[6] CHAN[5] CHAN[4] CHAN[3] CHAN[2] CHAN[1] CHAN[0]
0 0 0 0 0 0 0 0 0 0
This register contains the data read from the transmit channel provision RAM after an indirect read operation or the data to be inserted into the transmit channel provision RAM in an indirect write operation. CHAN[9:0]: The indirect data bits (CHAN[9:0]) report the channel number read from the transmit channel provision RAM after an indirect read operation has completed. Channel number to be written to the transmit channel provision RAM in an indirect write operation must be set up in this register before triggering the write. CHAN[9:0] reflects the value written until the completion of a subsequent indirect read operation. PROV: The indirect provision enable bit (PROV) reports the channel provision enable flag read from transmit channel provision RAM after an indirect read operation has completed. The provision enable flag to be written to the transmit channel provision RAM in an indirect write operation must be set up in this register before triggering the write. When PROV is set high, the current time-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
142
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
slot is assigned to the channel as indicated by CHAN[9:0]. When PROV is set low, the time-slot does not belong to any channel. The transmit link data is set to the contents of the Idle Time-slot Fill Data register. PROV reflects the value written until the completion of a subsequent indirect read operation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
143
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x40C : TCAS Idle Time-slot Fill Data Bit
Bit 15 to Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W
Type
Function
Unused
Default
XXH
FDATA[7] FDATA[6] FDATA[5] FDATA[4] FDATA[3] FDATA[2] FDATA[1] FDATA[0]
1 1 1 1 1 1 1 1
This register contains the data to be written to disabled time-slots of a channelised link. FDATA[7:0]: The fill data bits (FDATA[7:0]) are transmitted during disabled (PROV set low) time-slots of channelised links.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
144
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x410 : TCAS Channel Disable Bit
Bit 15 Bit 14 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R/W
Function
CHDIS Unused
Default
0 XXH
DCHAN[9] DCHAN[8] DCHAN[7] DCHAN[6] DCHAN[5] DCHAN[4] DCHAN[3] DCHAN[2] DCHAN[1] DCHAN[0]
0 0 0 0 0 0 0 0 0 0
This register controls the disabling of one specific channel to allow orderly provisioning of time-slots. DCHAN[9:0]: The disable channel number bits (DCHAN[9:0]) selects the channel to be disabled. When CHDIS is set high, the channel specified by DCHAN[9:0] is disabled. Data in time-slots associated with the specified channel is set to FDATA[7:0] in the Idle Time-slot Fill Data register. When CHDIS is set low, the channel specified by DCHAN[9:0] operates normally. CHDIS: The channel disable bit (CHDIS) controls the disabling of the channels specified by DCHAN[9:0]. When CHDIS is set high, the channel selected by DCHAN[9:0] is disabled. Data in time-slots associated with the specified channel is set to FDATA[7:0] in the Idle Time-slot Fill Data register. When CHDIS is set low, the channel specified by DCHAN[9:0] operates normally.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
145
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x440 : TCAS SBI SPE1 Configuration Register #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[11] FEN[10] FEN[9] FEN[8] FEN[7] FEN[6] FEN[5] FEN[4] FEN[3] FEN[2] FEN[1] FEN[0] Unused SBI_MODE[2] SBI_MODE[1] SBI_MODE[0]
Default
0 0 0 0 0 0 0 0 0 0 0 0 X 0 0 0
This register configures the operational mode of transmit links 0, 3, 6, 9, ... 33, 36, 39, ...81, i.e. those links mapped to SPE 1 of the SBI ADD BUS. SBI_MODE[2:0]: The SBI mode select bits (SBI_MODE[2:0]) configure the transmit links of SPE1, as shown in the following table:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
146
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 23 - SBI Mode SPE1 Configuration SBI_MODE [2:0] 000 001 010 011 100 101 110 111
FEN[11:0] Each FEN bit, FEN[n], configures link 3n for framed operation. In unframed operation (FEN[n] = 0), HDLC data is transmitted in all framing bit locations. In framed mode (FEN[n] = 1), the framing bit locations are unused.
SPE1 Configuration Single unchannelised DS-3 on link 0 28 T1/J1 links 21 E1 links (links 63, 66, 69, ... , 81 are unused) Reserved Reserved Reserved Reserved Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
147
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x444 : TCAS SBI SPE1 Configuration Register #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[27] FEN[26] FEN[25] FEN[24] FEN[23] FEN[22] FEN[21] FEN[20] FEN[19] FEN[18] FEN[17] FEN[16] FEN[15] FEN[14] FEN[13] FEN[12]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The bits of this register set are used to configure the framing modes of transmit links 36, 39, 42 ... 81. FEN[27:12]: Each FEN bit, FEN[n], configures link 3n for framed operation. In unframed operation (FEN[n] = 0), HDLC data is transmitted in all framing bit locations. In framed mode (FEN[n] = 1), the framing bit locations are unused.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
148
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x448 : TCAS SBI SPE2 Configuration Register #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[11] FEN[10] FEN[9] FEN[8] FEN[7] FEN[6] FEN[5] FEN[4] FEN[3] FEN[2] FEN[1] FEN[0] Unused SBI_MODE[2] SBI_MODE[1] SBI_MODE[0]
Default
0 0 0 0 0 0 0 0 0 0 0 0 X 0 0 0
This register configures the operational mode of transmit links 1, 4, 7, 10, ... 34, 37, ...82, i.e. those links mapped to SPE 2 of the SBI ADD BUS. SBI_MODE[2:0]: The SBI mode select bits (SBI_MODE[2:0]) configure the transmit links of SPE2, as shown in the following table:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
149
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 24 - SBI Mode SPE2 Configuration SBI_MODE [2:0] 000 001 010 011 100 101 110 111
FEN[11:0] Each FEN bit, FEN[n], configures link 3n+1 for framed operation. In unframed operation (FEN[n] = 0), HDLC data is transmitted in all framing bit locations. In framed mode (FEN[n] = 1), the framing bit locations are unused.
SPE2 Configuration Single unchannelised DS-3 on link 1 28 T1/J1 links 21 E1 links (links 64, 67, 70, ... , 82 are unused) Reserved Reserved Reserved Reserved Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
150
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x44C : TCAS SBI SPE2 Configuration Register #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[27] FEN[26] FEN[25] FEN[24] FEN[23] FEN[22] FEN[21] FEN[20] FEN[19] FEN[18] FEN[17] FEN[16] FEN[15] FEN[14] FEN[13] FEN[12]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The bits of this register set are used to configure the framing modes of transmit links 37, 40, 43 ... 82. FEN[27:12]: Each FEN bit, FEN[n], configures link 3n+1 for framed operation. In unframed operation (FEN[n] = 0), HDLC data is transmitted in all framing bit locations. In framed mode (FEN[n] = 1), the framing bit locations are unused.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
151
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x450 : TCAS SBI SPE3 Configuration Register #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[11] FEN[10] FEN[9] FEN[8] FEN[7] FEN[6] FEN[5] FEN[4] FEN[3] FEN[2] FEN[1] FEN[0] Unused SBI_MODE[2] SBI_MODE[1] SBI_MODE[0]
Default
0 0 0 0 0 0 0 0 0 0 0 0 X 0 0 0
This register configures the operational mode of transmit links 2, 5, 8, 11, ... 35, 38, ...83, i.e. those links mapped to SPE 3 of the SBI ADD BUS. SBI_MODE[2:0]: The SBI mode select bits (SBI_MODE[2:0]) configure the transmit links of SPE3, as shown in the following table:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
152
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 25 - SBI Mode SPE3 Configuration SBI_MODE [2:0] 000 001 010 011 100 101 110 111
FEN[11:0] Each FEN bit, FEN[n], configures link 3n+2 for framed operation. In unframed operation (FEN[n] = 0), HDLC data is transmitted in all framing bit locations. In framed mode (FEN[n] = 1), the framing bit locations are unused.
SPE3 Configuration Single unchannelised DS-3 on link 2 28 T1/J1 links 21 E1 links (links 65, 68, 71, ... , 83 are unused) Reserved Reserved Reserved Reserved Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
153
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x454 : TCAS SBI SPE3 Configuration Register #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
FEN[27] FEN[26] FEN[25] FEN[24] FEN[23] FEN[22] FEN[21] FEN[20] FEN[19] FEN[18] FEN[17] FEN[16] FEN[15] FEN[14] FEN[13] FEN[12]
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The bits of this register set are used to configure the framing modes of transmit links 38, 41, 44 ... 83. FEN[27:12]: Each FEN bit, FEN[n], configures link 3n+2 for framed operation. In unframed operation (FEN[n] = 0), HDLC data is transmitted in all framing bit locations. In framed mode (FEN[n] = 1), the framing bit locations are unused.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
154
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x480 - 0x488 : TCAS Links #0 to #2 Configuration Bit
Bit 15 to Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W
Type
Function
Unused
Default
XXXH
Reserved Unused Reserved Reserved Reserved
0 X 0 0 0
This register controls the operation of transmit links #0 to #2 when they are configured to transmit data on the TD[2:0] outputs (i.e. SPEn_EN is low). Reserved: The reserved bits must be set low for correct operation of the FREEDM84A672 device.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
155
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x500 : PMON Status Bit
Bit 15 to Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R R R R
Type
Function
Unused
Default
XXXH
C2DET C1DET UFDET OFDET Unused Unused
X X X X X X
This register contains status information indicating whether a non-zero count has been latched in the count registers. OFDET: The overflow detect bit (OFDET) indicates the status of the PMON Receive FIFO Overflow Count register. OFDET is set high when overflow events have occurred during the latest PMON accumulation interval. OFDET is set low if no overflow events are detected. UFDET: The underflow detect bit (UFDET) indicates the status of the PMON Transmit FIFO Underflow Count register. UFDET is set high when underflow events have occurred during the latest PMON accumulation interval. UFDET is set low if no underflow events are detected. C1DET: The configurable event #1 detect bit (C1DET) indicates the status of the PMON Configurable Count #1 register. C1DET is set high when selected events have occurred during the latest PMON accumulation interval. C1DET is set low if no selected events are detected. C2DET: The configurable event #2 detect bit (C2DET) indicates the status of the PMON Configurable Count #2 register. C2DET is set high when selected
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
156
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
events have occurred during the latest PMON accumulation interval. C2DET is set low if no selected events are detected.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
157
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x504 : PMON Receive FIFO Overflow Count Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R R R R R R R R R R R R R R R R
Function
OF[15] OF[14] OF[13] OF[12] OF[11] OF[10] OF[9] OF[8] OF[7] OF[6] OF[5] OF[4] OF[3] OF[2] OF[1] OF[0]
Default
X X X X X X X X X X X X X X X X
This register reports the number of receive FIFO overflow events in the previous accumulation interval. OF[15:0]: The OF[15:0] bits reports the number of receive FIFO overflow events that have been detected since the last time this register was polled. This register is polled by writing to the FREEDM-84A672 Master Clock / Frame Pulse Activity Monitor and Accumulation Trigger register. The write access transfers the internally accumulated error count to the FIFO overflow register and simultaneously resets the internal counter to begin a new cycle of error accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
158
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x508 : PMON Transmit FIFO Underflow Count Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R R R R R R R R R R R R R R R R
Function
UF[15] UF[14] UF[13] UF[12] UF[11] UF[10] UF[9] UF[8] UF[7] UF[6] UF[5] UF[4] UF[3] UF[2] UF[1] UF[0]
Default
X X X X X X X X X X X X X X X X
This register reports the number of transmit FIFO underflow events in the previous accumulation interval. UF[15:0]: The UF[15:0] bits reports the number of transmit FIFO underflow events that have been detected since the last time this register was polled. This register is polled by writing to the FREEDM-84A672 Master Clock / Frame Pulse Activity Monitor and Accumulation Trigger register. The write access transfers the internally accumulated error count to the FIFO underflow register and simultaneously resets the internal counter to begin a new cycle of error accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
159
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x50C : PMON Configurable Count #1 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R R R R R R R R R R R R R R R R
Function
C1[15] C1[14] C1[13] C1[12] C1[11] C1[10] C1[9] C1[8] C1[7] C1[6] C1[5] C1[4] C1[3] C1[2] C1[1] C1[0]
Default
X X X X X X X X X X X X X X X X
This register reports the number events, selected by the FREEDM-84A672 Master Performance Monitor Control register, that occurred in the previous accumulation interval. C1[15:0]: The C1[15:0] bits reports the number of selected events that have been detected since the last time this register was polled. This register is polled by writing to the FREEDM-84A672 Master Clock / Frame Pulse Activity Monitor and Accumulation Trigger register. The write access transfers the internally accumulated error count to the configurable count #1 register and simultaneously resets the internal counter to begin a new cycle of event accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
160
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x510 : PMON Configurable Count #2 Bit
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Type
R R R R R R R R R R R R R R R R
Function
C2[15] C2[14] C2[13] C2[12] C2[11] C2[10] C2[9] C2[8] C2[7] C2[6] C2[5] C2[4] C2[3] C2[2] C2[1] C2[0]
Default
X X X X X X X X X X X X X X X X
This register reports the number events, selected by the FREEDM-84A672 Master Performance Monitor Control register, that occurred in the previous accumulation interval. C2[15:0]: The C2[15:0] bits reports the number of selected events that have been detected since the last time this register was polled. This register is polled by writing to the FREEDM-84A672 Master Clock / Frame Pulse Activity Monitor and Accumulation Trigger register. The write access transfers the internally accumulated error count to the configurable count #2 register and simultaneously resets the internal counter to begin a new cycle of event accumulation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
161
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x580 : RAPI Control Bit
Bit 15 Bit 14 Bit 13 Bit 12 to Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W
Type
R/W R/W R/W
Function
ENABLE STATEN Reserved Unused
Default
0 0 0 XXXH
ALL1ENB BADDR[2] BADDR[1] BADDR[0]
1 1 1 1
This register provides the base address of the Rx APPI for purposes of responding to polling and device selection. This register also enables the RAPI672. BADDR[2:0]: The base address bits (BADDR[2:0]) configure the address space occupied by the FREEDM-84A672 device for purposes of responding to receive polling and receive device selection. During polling, the BADDR[2:0] bits are used to respond to polling via the RXADDR[2:0] pins. During device selection, the BADDR[2:0] are used to select a FREEDM-84A672 device, enabling it to accept data on the receive APPI. During data transfer, the RXDATA[15:13] pins of the prepended channel address reflect the BADDR[2:0] bits. ALL1ENB: The All Ones Enable bit (ALL1ENB) permits the FREEDM-84A672 to respond to receive polling and device selection when BADDR[2:0] = `111'. When ALL1ENB is zero, the FREEDM-84A672 responds to receive polling and device selection when BADDR[2:0] = RXADDR[2:0] = `111'. When ALL1ENB is one, the FREEDM-84A672 regards the all-ones address as a null address and does not respond to receive polling and device selection when BADDR[2:0] = `111', regardless of the value of RXADDR[2:0].
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
162
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Reserved: The reserved bit must be set to zero for correct operation of the FREEDM84A672 device. STATEN: The RAPI672 Status Enable bit (STATEN) enables the RAPI672 to provide the status of an errored packet on RXDATA[7:0] during transfer of the final word of that packet on the receive APPI (REOP and RERR high). When STATEN is set high, the RAPI672 overwrites RXDATA[7:0] of the final word of an errored packet with status information for that packet. When STATEN is set low, the RAPI672 does not report detailed status information for an errored packet. The RXDATA[15:0] connector description details the errored packet status reporting when STATEN is set high. ENABLE: The RAPI672 Enable bit (ENABLE) enables normal operation of the RAPI672. When ENABLE is set low, the RAPI672 will not transfer data from the RHDL672 into its internal FIFOs. When ENABLE is set high, the RAPI672 operates normally.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
163
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x5C0 : SBI EXTRACT Control Bit
Bit 15 to Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W
Type
Function
Unused
Default
XXH
Reserved Unused Unused Reserved Reserved Reserved SBI_PERR_EN SBI_PAR_CTL
0 X X 0 0 0 0 1
This register controls the operation of the SBI EXTRACT block. SBI_PAR_CTL The SBI_PAR_CTL bit is used to configure the Parity mode for checking of the SBI parity signal, DDP as follows: When SBI_PAR_CTL is '0' parity is even. When SBI_PAR_CTL is `1' parity is odd. SBI_PERR_EN The SBI_PERR_EN bit is used to enable SBI Parity Error interrupt generation. When SBI_PERR_EN is `0', SBI Parity Error Interrupts are disabled. When SBI_PERR_EN is `1', SBI Parity Error Interrupts are enabled. In both cases the SBI Parity checker logic will update the SBI EXTRACT Parity Error Interrupt Reason Register when a parity error occurs. Reserved: The reserved bits must be set low for correct operation of the FREEDM84A672 device.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
164
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x5CC : SBI EXTRACT Tributary RAM Indirect Access Address Bit
Bit 15 to Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W
Type
Function
Unused
Default
XXH
Reserved SPE[1] SPE[0] TRIB[4] TRIB[3] TRIB[2] TRIB[1] TRIB[0]
0 0 0 0 0 0 0 0
This register provides the receive SPE and link number used to access the SBI EXTRACT tributary control configuration RAM. TRIB[4:0] and SPE[1:0] The TRIB[4:0] and SPE[1:0] fields are used to specify which SBI tributary the control configuration RAM write or read operation will apply to. Legal values for TRIB[4:0] are b'00001' through b`11100'. Legal values for SPE[1:0] are b'01' through b`11'. Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
165
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x5D0 : SBI EXTRACT Tributary RAM Indirect Access Control Bit
Bit 15 to Bit 8 Bit 7 Bit 6 to Bit 2 Bit 1 Bit 0 R/W R/W R/W
Type
Function
Unused
Default
XXH
BUSY Unused
X XXH
RWB Reserved
0 0
This register controls access the SBI EXTRACT tributary control configuration RAM. Writing to this register triggers an indirect register access. Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device. RWB The indirect access control bit (RWB) selects between a configure (write) or interrogate (read) access to the tributary control configuration RAM. Writing a `0' to RWB triggers an indirect write operation. Data to be written is taken from the SBI EXTRACT Tributary RAM Indirect Access Data Register. Writing a `1' to RWB triggers an indirect read operation. The data read can be found in the SBI EXTRACT Tributary RAM Indirect Access Data Register. BUSY The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set high when a write to the SBI EXTRACT Tributary RAM Indirect Access Control Register triggers an indirect access and will stay high until the access is complete. This register should be polled to determine when data from an indirect read operation is available in the SBI EXTRACT Tributary RAM Indirect Access Data Register or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
166
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x5D8 : SBI EXTRACT Tributary RAM Indirect Access Data Bit
Bit 15 to Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W
Type
Function
Unused
Default
XXXH
Reserved Reserved Reserved TRIB_TYP[1] TRIB_TYP[0] Reserved ENBL
0 0 0 0 0 0 0
This register contains data read from the SBI EXTRACT tributary control configuration RAM after an indirect read operation or data to be written to the tributary control configuration RAM in an indirect write operation. ENBL The ENBL bit is used to enable the Tributary. Writing to the SBI EXTRACT tributary control configuration RAM with the ENBL bit set enables the SBI EXTRACT block to take tributary data from an SBI tributary and output that data to the SBI PISO blocks. Reserved: The reserved bits must be set low for correct operation of the FREEDM84A672 device. TRIB_TYP[1:0] The TRIB_TYP[1:0] field is used to specify the characteristics of the SBI tributary as shown in Table 26 below:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
167
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 26 - TRIB_TYP Encoding TRIB_TYP[1:0] 00 01 10 11 Tributary type Reserved Framed Unframed Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
168
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x5DC : SBI EXTRACT Parity Error Interrupt Reason Bit
Bit 15 to Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R
Type
Function
Unused
Default
XXH
SPE[1] SPE[0] TRIB[4] TRIB[3] TRIB[2] TRIB[1] TRIB[0] PERRI
0 1 0 0 0 0 1 0
This register provides information about the most recent parity error on the SBI DROP BUS. PERRI When set PERRI indicates that an SBI parity error has been detected. Reading the SBI EXTRACT Parity Error Interrupt Reason Register clears this bit. TRIB[4:0] and SPE[1:0] The TRIB[4:0] and SPE[1:0] fields specify the SBI tributary for which a parity error was detected. These fields are only valid when PERRI is set.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
169
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x600 : TAPI Control Bit
Bit 15 Bit 14 Bit 13 Bit 12 to Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W
Type
R/W R/W R/W
Function
ENABLE Reserved Reserved Unused
Default
0 0 0 XXXH
ALL1ENB BADDR[2] BADDR[1] BADDR[0]
1 1 1 1
This register provides the base address of the Tx APPI for purposes of responding to polling and Tx APPI data transfers. This register also enables the TAPI672. BADDR[2:0]: The base address bits (BADDR[2:0]) configure the address space occupied by the FREEDM-84A672 device for purposes of responding to transmit polling and transmit data transfers. During polling, the TXADDR[12:10] pins are compared with the BADDR[2:0] bits to determine if the poll address identified by TXADDR[9:0] is intended for a channel in this FREEDM-84A672 device. During data transmission, the TXDATA[15:13] pins of the prepended channel address are compared with the BADDR[2:0] bits to determine if the data to follow is intended for this FREEDM-84A672 device. ALL1ENB: The All Ones Enable bit (ALL1ENB) permits the FREEDM-84A672 to respond to transmit polling and device selection when BADDR[2:0] = `111'. When ALL1ENB is zero, the FREEDM-84A672 responds to transmit polling when BADDR[2:0] = TXADDR[12:10] = `111' and device selection when BADDR[2:0] = TXDATA[15:13] = `111'. When ALL1ENB is one, the FREEDM84A672 regards the all-ones address as a null address and does not respond to transmit polling and device selection when BADDR[2:0] = `111', regardless of the values of TXADDR[12:10] and TXDATA[15:13].
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
170
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Reserved: The reserved bits must be set to zero for correct operation of the FREEDM84A672 device. ENABLE: The TAPI672 Enable bit (ENABLE) enables normal operation of the TAPI672. When ENABLE is set low, the TAPI672 will complete the current data transfer and will respond to any further transactions on the Tx APPI normally (by setting TRDY high), but data provided will be ignored. When ENABLE is set high, the TAPI672 operates normally.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
171
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x604 : TAPI Indirect Channel Provisioning Bit
Bit 15 Bit 14 Bit 13 to Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Type
R R/W
Function
BUSY RWB Unused
Default
X 0 XH
CHAN[9] CHAN[8] CHAN[7] CHAN[6] CHAN[5] CHAN[4] CHAN[3] CHAN[2] CHAN[1] CHAN[0]
0 0 0 0 0 0 0 0 0 0
The Indirect Channel Provisioning Register provides the channel number used to access the TAPI672 channel provisioning RAM. Writing to this register triggers an indirect channel register access. CHAN[9:0]: The indirect channel number bits (CHAN[9:0]) indicate the channel to be configured or interrogated in the indirect access. RWB: The Read/Write Bar (RWB) bit selects between a provisioning/unprovisioning operation (write) or a query operation (read). Writing a logic 0 to RWB triggers the provisioning or unprovisioning of the channel specified by CHAN[9:0]. Writing a logic 1 to RWB triggers a query of the channel specified by CHAN[9:0].
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
172
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
BUSY: The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set high when this register is written to trigger an indirect access, and will stay high until the access is complete. At which point, BUSY will be set low. This register should be polled to determine when data from an indirect read operation is available or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
173
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x608 : TAPI Indirect Channel Data Register Bit
Bit 15 Bit 14 to Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W
Type
R/W
Function
PROV Unused
Default
0 XH
BLEN[7] BLEN[6] BLEN[5] BLEN[4] BLEN[3] BLEN[2] BLEN[1] BLEN[0]
0 0 0 0 0 0 0 0
The TAPI Indirect Channel Data Register contains data read from the TAPI672 channel provision RAM after an indirect read operation or data to be written to channel provision RAM in an indirect write operation. BLEN[7:0]: The channel burst length (BLEN[7:0]) bits report the data transfer burst length read from the TAPI672 channel provision RAM after an indirect read operation has completed. The data transfer burst length specifies the length (in bytes, less one) of burst data transfers on the transmit APPI which are not terminated by the assertion of TEOP. The data transfer burst length can be specified on a per-channel basis. The data transfer burst length to be written to the channel provision RAM in an indirect write operation must be set up in this register before triggering the write. BLEN[7:0] reflects the value written until the completion of a subsequent indirect read operation. PROV: The indirect provision enable bit (PROV) reports the channel provision enable flag read from the TAPI672 channel provision RAM after an indirect read operation has completed. The provision enable flag to be written to the TAPI672 channel provision RAM, in an indirect write operation, must be set up in this register before triggering the write. When PROV is set high, the
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
174
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
channel as indicated by CHAN[9:0] is provisioned. When PROV is set low, the channel indicated by CHAN[9:0] is unprovisioned. PROV reflects the value written until the completion of a subsequent indirect read operation.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
175
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x680 : SBI INSERT Control Bit
Bit 15 to Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W
Type
Function
Unused
Default
XXH
Reserved Unused Unused Reserved Reserved Reserved Unused SBI_PAR_CTL
0 X X 0 0 0 X 1
This register controls the operation of the SBI INSERT block. SBI_PAR_CTL The SBI_PAR_CTL bit is used to configure the Parity mode for generation of the SBI parity signal, ADP as follows: When SBI_PAR_CTL is '0' parity is even. When SBI_PAR_CTL is `1' parity is odd. Reserved: The reserved bits must be set low for correct operation of the FREEDM84A672 device.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
176
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x68C : SBI INSERT Tributary RAM Indirect Access Address Bit
Bit 15 to Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W R/W R/W R/W
Type
Function
Unused
Default
XXH
Reserved SPE[1] SPE[0] TRIB[4] TRIB[3] TRIB[2] TRIB[1] TRIB[0]
0 0 0 0 0 0 0 0
This register provides the transmit SPE and link number used to access the SBI INSERT tributary control configuration RAM. TRIB[4:0] and SPE[1:0] The TRIB[4:0] and SPE[1:0] fields are used to specify which SBI tributary the control configuration RAM write or read operation will apply to. Legal values for TRIB[4:0] are b'00001' through b`11100'. Legal values for SPE[1:0] are b'01' through b`11'. Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
177
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x690 : SBI INSERT Tributary RAM Indirect Access Control Bit
Bit 15 to Bit 8 Bit 7 Bit 6 to Bit 2 Bit 1 Bit 0 R/W R/W R/W
Type
Function
Unused
Default
XXH
BUSY Unused
X XXH
RWB Reserved
0 0
This register controls access to the SBI INSERT tributary control configuration RAM. Writing to this register triggers an indirect register access. Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device. RWB The indirect access control bit (RWB) selects between a configure (write) or interrogate (read) access to the tributary control configuration RAM. Writing a `0' to RWB triggers an indirect write operation. Data to be written is taken from the SBI INSERT Tributary RAM Indirect Access Data Register. Writing a `1' to RWB triggers an indirect read operation. The data read can be found in the SBI INSERT Tributary RAM Indirect Access Data Register. BUSY The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set high when a write to the SBI INSERT Tributary RAM Indirect Access Control Register triggers an indirect access and will stay high until the access is complete. This register should be polled to determine when data from an indirect read operation is available in the SBI INSERT Tributary RAM Indirect Access Data Register or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
178
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Register 0x698 : SBI INSERT Tributary RAM Indirect Access Data Bit
Bit 15 to Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 R/W R/W R/W R/W R/W
Type
Function
Unused
Default
XXXH
CLK_MSTR TRIB_TYP[1] TRIB_TYP[0] Reserved ENBL
0 0 0 0 0
This register contains data read from the SBI INSERT tributary control configuration RAM after an indirect read operation or data to be written to the tributary control configuration RAM in an indirect write operation. ENBL The ENBL bit is used to enable the Tributary. Writing to the SBI INSERT tributary control configuration RAM with the ENBL bit set enables the SBI INSERT block to output tributary data on an SBI tributary. Reserved: The reserved bit must be set low for correct operation of the FREEDM84A672 device. TRIB_TYP[1:0] The TRIB_TYP[1:0] field is used to specify the characteristics of the SBI tributary as shown in Table 27 below:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
179
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 27 - TRIB_TYP Encoding TRIB_TYP[1:0] 00 01 10 11
CLK_MSTR The CLK_MSTR bit configures the SBI tributary to operate as a timing master or slave. Setting CLK_MSTR to 1 configures the tributary as a timing master (AJUST_REQ input ignored). Setting CLK_MSTR to 0 configures the tributary as a timing slave (requests on AJUST_REQ honoured).
Tributary type Reserved Framed Unframed Reserved
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
180
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
10
TEST FEATURES DESCRIPTION
The FREEDM-84A672 also supports a standard IEEE 1149.1 five signal JTAG boundary scan test port for use in board testing. All device inputs may be read and all device outputs may be forced via the JTAG test port.
10.1 Test Mode Registers
Test mode registers are used to apply test vectors during production testing of the FREEDM-84A672. Production testing is enabled by asserting the PMCTEST pin. During production tests, FREEDM-84A672 registers are selected by the TA[12:0] pins. Read accesses are enabled by asserting TRDB low while write accesses are enabled by asserting TWRB low. Test mode register data is conveyed on the TDAT[15:0] pins. Test mode registers (as opposed to normal mode registers) are selected when TA[12]/TRS is set high.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
181
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 28 - Test Mode Register Memory Map Address TA[12:0]
0x0000 - 0x07FE 0x0800 - 0x10FE 0x1100 - 0x11FE 0x1200 - 0x123E 0x1240 - 0x137E 0x1380 - 0x13BE 0x13C0 - 0x13FE 0x1400 - 0x14FE 0x1500 - 0x151E 0x1520 - 0x157E 0x1580 - 0x15BE 0x15C0 - 0x15FE 0x1600 - 0x163E 0x1640 - 0x167E 0x1680 - 0x16FE 0x1700 - 0x17FE 0x1800 - 0x18FE 0x1900 - 0x19FE 0x1A00 - 0x1AFE 0x1B00 - 0x1BFE 0x1C00 - 0x1CFE 0x1D00 - 0x1DFE 0x1E00 - 0x1FFE
Register
Normal Mode Registers Reserved RCAS672 Test Registers RHDL672 Test Registers Reserved THDL672 Test Registers Reserved TCAS672 Test Registers PMON Test Registers Reserved RAPI672 Test Registers SBI EXTRACT Test Registers TAPI672 Test Registers Reserved SBI INSERT Test Registers Reserved SBI PISO#1 Test Registers SBI PISO#2 Test Registers SBI PISO#3 Test Registers SBI SIPO#1 Test Registers SBI SIPO#2 Test Registers SBI SIPO#3 Test Registers Reserved
Notes on Test Mode Register Bits:
1. Writing values into unused register bits has no effect. However, to ensure software compatibility with future, feature-enhanced versions of the product, unused register
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
182
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
bits must be written with logic zero. Reading back unused bits can produce either a logic one or a logic zero; hence unused register bits should be masked off by software when read. 2. Writable test mode register bits are not initialized upon reset unless otherwise noted.
10.2 JTAG Test Port
The FREEDM-84A672 JTAG Test Access Port (TAP) allows access to the TAP controller and the 4 TAP registers: instruction, bypass, device identification and boundary scan. Using the TAP, device input logic levels can be read, device outputs can be forced, the device can be identified and the device scan path can be bypassed. For more details on the JTAG port, please refer to the Operations section.
Table 29 - Instruction Register Length - 3 bits Instructions
EXTEST IDCODE SAMPLE BYPASS BYPASS STCTEST BYPASS BYPASS
Selected Register
Boundary Scan Identification Boundary Scan Bypass Bypass Boundary Scan Bypass Bypass
Instruction Code IR[2:0]
000 001 010 011 100 101 110 111
10.2.1 Identification Register
Length - 32 bits Version number - 2H Part Number - 7385H Manufacturer's identification code - 0CDH Device identification - 273850CDH
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
183
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
10.2.2 Boundary Scan Register
The boundary scan register is made up of 365 boundary scan cells, divided into input observation (in_cell), output (out_cell), and bi-directional (io_cell) cells. These cells are detailed in the following pages. The first 32 cells form the ID code register, and carry the code 273850CDH. The cells are arranged as follows:
Table 30 - Boundary Scan Chain Pin/Enable
Unconnected Unconnected Unconnected Unconnected FASTCLK Logic 0 SPE1_EN SPE2_EN SPE3_EN TD_OEN[0] TD[0] TCLK[0] TD_OEN[1] TD[1] TCLK[1] TD_OEN[2] TD[2] TCLK[2] C1FPOUT_OEN C1FPOUT REFCLK APL_OEN
Register Bit
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Cell Type
OUT_CELL OUT_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
184
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
APL DPL AV5_OEN AV5 DV5 ADP_OEN ADP DDP AACTIVE_OEN AACTIVE C1FP Logic 0 Logic 0 ADATA_OEN[0] ADATA[0] DDATA[0] ADATA_OEN[1] ADATA[1] DDATA[1] ADATA_OEN[2] ADATA[2] DDATA[2] ADATA_OEN[3] ADATA[3] DDATA[3] ADATA_OEN[4] ADATA[4] DDATA[4]
Register Bit
22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49
Cell Type
OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
185
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
ADATA_OEN[5] ADATA[5] DDATA[5] ADATA_OEN[6] ADATA[6] DDATA[6] ADATA_OEN[7] ADATA[7] DDATA[7] Logic 0 Logic 0 TDAT_OEN[0] TDAT[0] AJUST_REQ TDAT_OEN[1] TDAT[1] ADETECT[0] TDAT_OEN[2] TDAT[2] ADETECT[1] TDAT_OEN[3] TDAT[3] Logic 0 TDAT_OEN[4] TDAT[4] Logic 0 TDAT_OEN[5] TDAT[5]
Register Bit
50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77
Cell Type
OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
186
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
Logic 0 TDAT_OEN[6] TDAT[6] Logic 0 TDAT_OEN[7] TDAT[7] Logic 0 Logic 0 Logic 0 TDAT_OEN[8] TDAT[8] Logic 0 TDAT_OEN[9] TDAT[9] Logic 0 TDAT_OEN[10] TDAT[10] Logic 0 TDAT_OEN[11] TDAT[11] Logic 0 TDAT_OEN[12] TDAT[12] Logic 0 TDAT_OEN[13] TDAT[13] Logic 0 TDAT_OEN[14]
Register Bit
78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105
Cell Type
IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL IN_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
187
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
TDAT[14] Logic 0 TDAT_OEN[15] TDAT[15] Logic 0 Logic 0 Unconnected Unconnected PMCTEST RXADDR[0] RXADDR[1] RXADDR[2] RXCLK RXDATA_OEN[0] RXDATA[0] RXDATA_OEN[1] RXDATA[1] RXDATA_OEN[2] RXDATA[2] RXDATA_OEN[3] RXDATA[3] RXDATA_OEN[4] RXDATA[4] RXDATA_OEN[5] RXDATA[5] RXDATA_OEN[6] RXDATA[6] RXDATA_OEN[7]
Register Bit
106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133
Cell Type
IO_CELL IN_CELL OUT_CELL IO_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
188
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
RXDATA[7] RSX_OEN RSX RXDATA_OEN[8] RXDATA[8] RXDATA_OEN[9] RXDATA[9] RXDATA_OEN[10] RXDATA[10] RXDATA_OEN[11] RXDATA[11] RXDATA_OEN[12] RXDATA[12] RXDATA_OEN[13] RXDATA[13] RXDATA_OEN[14] RXDATA[14] RXDATA_OEN[15] RXDATA[15] RXPRTY_OEN RXPRTY RERR_OEN RERR RMOD_OEN RMOD REOP_OEN REOP RENB
Register Bit
134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161
Cell Type
IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL IN_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
189
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
RPA_OEN RPA RVAL_OEN RVAL TRDY_OEN TRDY TERR_OEN TERR TMOD_OEN TMOD TEOP_OEN TEOP TXDATA_OEN[0] TXDATA[0] TXDATA_OEN[1] TXDATA[1] TXDATA_OEN[2] TXDATA[2] TXDATA_OEN[3] TXDATA[3] TXDATA_OEN[4] TXDATA[4] TXDATA_OEN[5] TXDATA[5] TXDATA_OEN[6] TXDATA[6] TXDATA_OEN[7] TXDATA[7]
Register Bit
162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189
Cell Type
OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
190
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
TSX TXPRTY_OEN TXPRTY TXDATA_OEN[8] TXDATA[8] TXDATA_OEN[9] TXDATA[9] TXDATA_OEN[10] TXDATA[10] TXDATA_OEN[11] TXDATA[11] TXDATA_OEN[12] TXDATA[12] TXDATA_OEN[13] TXDATA[13] TXDATA_OEN[14] TXDATA[14] TXDATA_OEN[15] TXDATA[15] Unconnected Unconnected TXCLK TXADDR[0] TXADDR[1] TXADDR[2] Unconnected Unconnected TXADDR[3]
Register Bit
190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217
Cell Type
IN_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL IN_CELL IN_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
191
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
TXADDR_OEN[4] TXADDR[4] TXADDR[5] TXADDR[6] TXADDR[7] TXADDR[8] TXADDR[9] TXADDR[10] TXADDR[11] TXADDR[12] TPA1_OEN[0] TPA1[0] TPA1_OEN[1] TPA1[1] TPA1_OEN[2] TPA1[2] TPA2_OEN[0] TPA2[0] TPA2_OEN[1] TPA2[1] TPA2_OEN[2] TPA2[2] D_OEN[0] D[0] D_OEN[1] D[1] D_OEN[2] D[2]
Register Bit
218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245
Cell Type
OUT_CELL IO_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
192
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
D_OEN[3] D[3] D_OEN[4] D[4] D_OEN[5] D[5] D_OEN[6] D[6] D_OEN[7] D[7] D_OEN[8] D[8] D_OEN[9] D[9] D_OEN[10] D[10] D_OEN[11] D[11] D_OEN[12] D[12] D_OEN[13] D[13] D_OEN[14] D[14] D_OEN[15] D[15] A[2] A[3]
Register Bit
246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273
Cell Type
OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL IN_CELL IN_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
193
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
A[4] A[5] A[6] A[7] A[8] A[9] A[10] A[11] ALE WRB RDB CSB INTB_OEN INTB Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0
Register Bit
274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301
Cell Type
IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
194
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
Logic 0 TA[12] Logic 0 Logic 0 Logic 0 TWRB Logic 0 TRDB Logic 0 TA[11] Logic 0 TA[10] Logic 0 TA[9] Logic 0 TA[8] Logic 0 TA[7] Logic 0 TA[6] Logic 0 Logic 0 Logic 0 TA[5] RSTB Logic 0 TA[4] Logic 0
Register Bit
302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329
Cell Type
IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL
Device I.D.
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
195
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
TA[3] Logic 0 TA[2] Logic 0 TA[1] Logic 0 TA[0] Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 SYSCLK Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 RCLK[2] RD[2] RCLK[1] RD[1]
Register Bit
330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357
Cell Type
IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL
Device I.D.
1 0 1 1 0 0 1 1 0 0 0 0 1 0 1 0 0 0 0 1 1 1 0 0 1
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
196
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Pin/Enable
RCLK[0] RD[0] Logic 0 Logic 0 Logic 0 Logic 0 Logic 0 TDO TDI TCK TMS TRSTB
Register Bit
358 359 360 361 362 363 364
Cell Type
IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL TAP Output TAP Input TAP Clock TAP Input TAP Input
Device I.D.
1 1 0 0 1 0 0 -
Notes:
1. Register bit 364 is the first bit of the scan chain (closest to TDI). 2. Enable cell pinname_OEN, tristates pin pinname when set high. 3. Cells `Logic 0' and `Logic 1' are Input Observation cells whose input pad is bonded to VSS or VDD internally. 4. Cells titled `Unconnected' are Output or Bi-directional cells whose pad is unconnected to the device package. In the case of bi-directional cells, the pad always drives (i.e. never tri-states) and the pad input is the same logic value as the pad output.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
197
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 5 - Input Observation Cell (IN_CELL)
IDCODE Scan Chain Out INPUT to internal logic
Input Pad
G1 G2 SHIFT-DR
I.D. Code bit CLOCK-DR
12 1 2 MUX 12 12
Scan Chain In
D C
In this diagram and those that follow, CLOCK-DR is equal to TCK when the current controller state is SHIFT-DR or CAPTURE-DR, and unchanging otherwise. The multiplexor in the center of the diagram selects one of four inputs, depending on the status of select lines G1 and G2. The ID Code bit is as listed in the table above.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
198
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 6 - Output Cell (OUT_CELL)
Scan Chain Out EXTEST Output or Enable from system logic IDCODE SHIFT-DR
G1 1 G1 G2 1 1 1 1 2 2 MUX 2 2 1
Output or Enable
MUX
D C
D C
I.D. code bit CLOCK-DR UPDATE-DR
Scan Chain In
Figure 7 - Bi-directional Cell (IO_CELL)
Scan Chain Out
EXTEST OUTPUT from internal logic IDCODE SHIFT-DR INPUT from pin I.D. code bit CLOCK-DR UPDATE-DR Scan Chain In
G1 1 G1 G2 12 1 2 MUX 12 12 D C D C 1
INPUT to internal logic
MUX
OUTPUT to pin
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
199
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 8 - Layout of Output Enable and Bi-directional Cells
Scan Chain Out OUTPUT ENABLE from internal logic (0 = drive)
OUT_CELL
Scan Chain In Scan Chain Out INPUT to internal logic OUTPUT from internal logic
IO_CELL
I/O PAD
Scan Chain In
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
200
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
11
OPERATIONS
This section presents operating details for the JTAG boundary scan feature.
11.1 JTAG Support
The FREEDM-84A672 supports the IEEE Boundary Scan Specification as described in the IEEE 1149.1 standards. The Test Access Port (TAP) consists of the five standard pins, TRSTB, TCK, TMS, TDI and TDO used to control the TAP controller and the boundary scan registers. The TRSTB input is the active low reset signal used to reset the TAP controller. TCK is the test clock used to sample data on input, TDI and to output data on output, TDO. The TMS input is used to direct the TAP controller through its states. The basic boundary scan architecture is shown below.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
201
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 9 - Boundary Scan Architecture
TDI
Boundary Scan Register Device Identification Register Bypass Register
Instruction Register and Decode
Mux DFF
TDO
TMS
Test Access Port Controller
Control Select Tri-state Enable
TRSTB TCK
The boundary scan architecture consists of a TAP controller, an instruction register with instruction decode, a bypass register, a device identification register and a boundary scan register. The TAP controller interprets the TMS input and generates control signals to load the instruction and data registers. The instruction register with instruction decode block is used to select the test to be executed and/or the register to be accessed. The bypass register offers a single bit delay from primary input, TDI to primary output , TDO. The device identification register contains the device identification code. The boundary scan register allows testing of board inter-connectivity. The boundary scan register consists of a shift register placed in series with device inputs and outputs. Using the boundary scan register, all digital inputs can be
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
202
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
sampled and shifted out on primary output TDO. In addition, patterns can be shifted in on primary input, TDI and forced onto all digital outputs.
TAP Controller
The TAP controller is a synchronous finite state machine clocked by the rising edge of primary input, TCK. All state transitions are controlled using primary input, TMS. The finite state machine is described below.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
203
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 10 - TAP Controller Finite State Machine
TRSTB=0 Test-Logic-Reset 1 0 1 Run-Test-Idle 0 1 Capture-DR 0 Shift-DR 1 Exit1-DR 0 Pause-DR 1 0 Exit2-DR 1 Update-DR 1 0 0 0 0 1 Select-DR-Scan 0 1 Capture-IR 0 Shift-IR 1 Exit1-IR 0 Pause-IR 1 Exit2-IR 1 Update-IR 1 0 0 0 1 1 Select-IR-Scan 0 1
All transitions dependent on input TMS
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
204
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Test-Logic-Reset
The test logic reset state is used to disable the TAP logic when the device is in normal mode operation. The state is entered asynchronously by asserting input, TRSTB. The state is entered synchronously regardless of the current TAP controller state by forcing input, TMS high for 5 TCK clock cycles. While in this state, the instruction register is set to the IDCODE instruction.
Run-Test-Idle
The run test/idle state is used to execute tests.
Capture-DR
The capture data register state is used to load parallel data into the test data registers selected by the current instruction. If the selected register does not allow parallel loads or no loading is required by the current instruction, the test register maintains its value. Loading occurs on the rising edge of TCK.
Shift-DR
The shift data register state is used to shift the selected test data registers by one stage. Shifting is from MSB to LSB and occurs on the rising edge of TCK.
Update-DR
The update data register state is used to load a test register's parallel output latch. In general, the output latches are used to control the device. For example, for the EXTEST instruction, the boundary scan test register's parallel output latches are used to control the device's outputs. The parallel output latches are updated on the falling edge of TCK.
Capture-IR
The capture instruction register state is used to load the instruction register with a fixed instruction. The load occurs on the rising edge of TCK.
Shift-IR
The shift instruction register state is used to shift both the instruction register and the selected test data registers by one stage. Shifting is from MSB to LSB and occurs on the rising edge of TCK.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
205
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Update-IR
The update instruction register state is used to load a new instruction into the instruction register. The new instruction must be scanned in using the Shift-IR state. The load occurs on the falling edge of TCK. The Pause-DR and Pause-IR states are provided to allow shifting through the test data and/or instruction registers to be momentarily paused.
Boundary Scan Instructions
The following is a description of the standard instructions. Each instruction selects a serial test data register path between input, TDI and output, TDO.
BYPASS
The bypass instruction shifts data from input, TDI to output, TDO with one TCK clock period delay. The instruction is used to bypass the device.
EXTEST
The external test instruction allows testing of the interconnection to other devices. When the current instruction is the EXTEST instruction, the boundary scan register is place between input, TDI and output, TDO. Primary device inputs can be sampled by loading the boundary scan register using the Capture-DR state. The sampled values can then be viewed by shifting the boundary scan register using the Shift-DR state. Primary device outputs can be controlled by loading patterns shifted in through input TDI into the boundary scan register using the Update-DR state.
SAMPLE
The sample instruction samples all the device inputs and outputs. For this instruction, the boundary scan register is placed between TDI and TDO. Primary device inputs and outputs can be sampled by loading the boundary scan register using the Capture-DR state. The sampled values can then be viewed by shifting the boundary scan register using the Shift-DR state.
IDCODE
The identification instruction is used to connect the identification register between TDI and TDO. The device's identification code can then be shifted out using the Shift-DR state.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
206
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
STCTEST
The single transport chain instruction is used to test out the TAP controller and the boundary scan register during production test. When this instruction is the current instruction, the boundary scan register is connected between TDI and TDO. During the Capture-DR state, the device identification code is loaded into the boundary scan register. The code can then be shifted out output, TDO using the Shift-DR state.
INTEST
The internal test instruction is used to exercise the device's internal core logic. When this instruction is the current instruction, the boundary scan register is connected between TDI and TDO. During the Update-DR state, patterns shifted in on input, TDI are used to drive primary inputs. During the Capture-DR state, primary outputs are sampled and loaded into the boundary scan register.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
207
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
12
FUNCTIONAL TIMING
12.1 SBI DROP BUS Interface Timing Figure 11 - T1/E1 DROP BUS Functional Timing
REFCLK C1FP DDATA[7:0] DPL DV5 DDP C1
*** *** *** *** *** ***
V3
V3
V3 DS0#4. V5 DS0#9.
Figure 11 illustrates the operation of the SBI DROP BUS, using a negative justification on the second to last V3 octet as an example. The justification is indicated by asserting DPL high during the V3 octet. The timing diagram also shows the location of one of the tributaries by asserting DV5 high during the V5 octet.
Figure 12 - DS3 DROP BUS Functional Timing
REFCLK C1FP DDATA[7:0] DPL DV5 DDP C1
*** *** *** *** *** ***
H3
H3
H3
DS-3 #1 DS-3 #2 DS-3 #3DS-3 #1
Figure 12 shows three DS-3 tributaries mapped onto the SBI bus. A negative justification is shown for DS-3 #2 during the H3 octet with DPL asserted high. A positive justification is shown for DS-3#1 during the first DS-3#1 octet after H3 which has DPL asserted low.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
208
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
12.2 SBI ADD BUS Interface Timing Figure 13 - DS3 Add Bus Adjustment Request Functional Timing
REFCLK C1FP ADATA[7:0] APL AV5 ADP AJUST_REQ AACTIVE C1 *** *** *** *** *** *** *** *** H3 H3 H3
DS-3 #1 DS-3 #2 DS-3 #3DS-3 #1
Figure 13 illustrates the operation of the SBI ADD BUS, using positive and negative justification requests as an example. (The responses to the justification requests would take effect during the next multi-frame.) The negative justification request occurs on the DS-3#3 tributary when AJUST_REQ is asserted high during the H3 octet. The positive justification occurs on the DS-3#2 tributary when AJUST_REQ is asserted high during the first DS-3#2 octet after the H3 octet. The AACTIVE signal is shown for the case in which FREEDM-84A672 is only driving DS-3#2 onto the SBI ADD bus.
12.3 Receive Link Timing
The timing relationship of the receive clock (RCLK[n]) and data (RD[n]) signals is shown in Figure 14. The receive data is viewed as a contiguous serial stream. There is no concept of time-slots or framing. Every eight bits are grouped together into a byte with arbitrary alignment. The first bit received (B1 in Figure 14) is deemed the most significant bit of an octet. The last bit received (B8) is deemed the least significant bit. Bits that are to be processed by the FREEDM84A672 are clocked in on the rising edge of RCLK[n]. Bits that should be ignored (X in Figure 14) are squelched by holding RCLK[n] quiescent. In Figure 14, the quiescent period is shown to be a low level on RCLK[n]. A high level, effected by extending the high phase of the previous valid bit, is also acceptable. Selection of bits for processing is arbitrary and is not subject to any byte alignment nor frame boundary considerations.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
209
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 14 - Receive Link Timing
RCLK[n] RD[n]
12.4 Transmit Link Timing
B1 B2 B3 B4 X B5 X X X B6 B7 B8 B1 X
The timing relationship of the transmit clock (TCLK[n]) and data (TD[n]) signals is shown in Figure 15. The transmit data is viewed as a contiguous serial stream. There is no concept of time-slots or framing. Every eight bits are grouped together into a byte with arbitrary byte alignment. Octet data is transmitted from most significant bit (B1 in Figure 15) and ending with the least significant bit (B8 in Figure 15). Bits are updated on the falling edge of TCLK[n]. A transmit link may be stalled by holding the corresponding TCLK[n] quiescent. In Figure 15, bits B5 and B2 are shown to be stalled for one cycle while bit B6 is shown to be stalled for three cycles. In Figure 15, the quiescent period is shown to be a low level on TCLK[n]. A high level, effected by extending the high phase of the previous valid bit, is also acceptable. Gapping of TCLK[n] can occur arbitrarily without regard to byte nor frame boundaries.
Figure 15 - Transmit Link Timing
TCLK[n] TD[n]
12.5 Receive APPI Timing
B1 B2 B3 B4 B5 B6 B7 B8 B1 B2
The receive Any-PHY packet interface (APPI) timing is shown in Figure 16 through Figure 19. The FREEDM-84A672 device provides data to an external controller using the receive APPI. The following discussion surrounding the receive APPI functional timing assumes that multiple FREEDM-84A672 devices share a single external controller. All Rx APPI signals are shared between the FREEDM-84A672 devices.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
210
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 16 - Receive APPI Timing (Normal Transfer)
RXCLK RXADDR[2:0] RPA RENB RXDATA[15:0] RVAL RSX REOP RMOD RERR CH 2 D0 Dev 0 D1 Dev 0 D2 D3 D4 D5 D6 D7 Dev 0 NULL Dev 7 Dev 0 NULL Dev 6 Dev 7 NULL Dev 4 Dev 6 NULL Dev 0 Dev 4 NULL Dev 1 Dev 0 NULL Dev 3 Dev 1 NULL Dev 2 Dev 3 NULL Dev 2
Figure 16 shows the transfer of an 8 word packet across the Rx APPI from FREEDM-84A672 device 0, channel 2. In this example, seven FREEDM-84A672 devices are sharing the Rx APPI, with device 5 being the null address. The data transfer begins when the external controller selects FREEDM-84A672 device 0 by placing that address on the RXADDR[2:0] inputs and setting RENB high. The external controller sets RENB low in the next RXCLK cycle to commence data transfer across the Rx APPI. The FREEDM-84A672 samples RENB low and responds by asserting RSX one RXCLK cycle later. The start of all burst data transfers is qualified with RSX and an in-band channel address on RXDATA[15:0] to associate the data to follow with a HDLC channel. During the cycle when D2 is placed on RXDATA[15:0], the external controller is unable to accept any further data and sets RENB high. Two RXCLK cycles later, the FREEDM-84A672 tristates the Rx APPI. The external controller may hold RENB high for an indeterminate number of RXCLK cycles. The FREEDM84A672 will wait until the external controller returns RENB low. Because the FREEDM-84A672 does not support interrupted data transfers on the Rx APPI, the external controller must reselect FREEDM-84A672 device 0 or output a null address during the clock cycle before it returns RENB low. However, while RENB remains high, the address on the RXADDR[2:0] signals may change. When the FREEDM-84A672 device 0 samples RENB low, it continues data transfer by providing D4 on RXDATA[15:0]. Note that if D3 were the final word of the packet (Status), in response to sampling REOP high, the external controller does not have to reselect FREEDM-84A672 device 0. This is shown in Figure 19. The FREEDM-84A672 will not pause burst data transfers across the Rx APPI. The FREEDM-84A672 automatically deselects at the end of all burst data transfers. The FREEDM-84A672 must be reselected before any further data will be transferred across the Rx APPI.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
211
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
The RVAL and REOP signals indicate the presence and end of valid packet data respectively. The RERR and RMOD signals are only valid at the end of a packet and are qualified with the REOP signal. When a packet is errored, the FREEDM84A672 may be programmed to overwrite RXDATA[15:0] in the final word of packet transfer with status information indicating the cause of the error. RXDATA[15:0] is not modified if a packet is error free. The RXADDR[2:0] signals serve to poll FREEDM-84A672 devices as well as for selection. During data transfer, the RXADDR[2:0] signals continue to poll the FREEDM-84A672 devices sharing the Rx APPI. Polled results are returned on the RPA signal. Note that each poll address is separated by a NULL address to generate tristate turn-around cycle in order to prevent multiple FREEDM-84A672 devices from briefly driving RPA. If RPA is a point-to-point signal for each FREEDM-84A672 device on the board, then the tristate turn-around cycle is not required, thereby effectively doubling the polling bandwidth at the expense of extra signals. Polled results reflect the status of the two FIFOs in the RAPI672. Polled responses always refer to the next data transfer. In other words, polled responses during or after the RXCLK cycle where RSX is set high refer to the FIFO which is not involved in the current data transfer. For example, once FIFO one begins transferring data on the Rx APPI (RSX set high), any polls against that FREEDM-84A672 device respond with the status of FIFO two. This allows the external controller to gather knowledge about the FIFO not involved in the current data transfer so that it can anticipate reselecting that FREEDM-84A672 device (via RENB) to maximize bandwidth on the Rx APPI (shown in Figure 18).
Figure 17 - Receive APPI Timing (Auto Deselection)
RXCLK RXADDR[2:0] RPA RENB RXDATA[15:0] RVAL RSX REOP RMOD RERR CH 2 D0 Dev 0 D1 D98 D99 CH 8 Dev 0 D0 D1 Dev 0 NULL Dev 7 Dev 0 NULL Dev 6 Dev 7 NULL Dev 4 NULL Dev 4 Dev 0 NULL Dev 0 Dev 3 NULL Dev 2 Dev 3 NULL Dev 2
Figure 17 shows the transfer of a 100 word packet across the Rx APPI from FREEDM-84A672 device 0, channel 2 followed by the transfer of a 2 word packet from FREEDM-84A672 device 0, channel 8. More importantly, Figure 17 illustrates that, for back-to-back transfers from the same FREEDM-84A672
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
212
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
(device 0), it must be reselected before any further data is provided on the Rx APPI. At the end of the first 100 word packet transfer across the Rx APPI, the FREEDM-84A672 automatically deselects and must be reselected before the second two word packet is transferred. When the external controller samples REOP high, it recognizes that the burst transfer has completed. Two RXCLK cycles later, the external controller reselects FREEDM-84A672 device 0 by setting RENB high and placing address 0 on the RXADDR[2:0] signals. When the FREEDM-84A672 samples RENB low, it begins the next data transfer as before.
Figure 18 - Receive APPI Timing (Optimal Reselection)
RXCLK RXADDR[2:0] RPA RENB Dev 0 RXDATA[15:0] RVAL RSX REOP RMOD RERR CH 2 D0 D1 D125 D126 D127 CH 2 Dev 0 D128 Dev 0 NULL Dev 7 Dev 0 NULL Dev 6 Dev 7 NULL NULL Dev 0 NULL Dev 4 Dev 0 NULL Dev 4 Dev 3 NULL
Figure 18 shows optimal bandwidth utilization across the Rx APPI. With knowledge that the maximum burst data transfer (excluding channel address prepend) is 256 bytes, i.e. 128 words, the external controller sets RENB high when the 127th word (D126) is placed on RXDATA[15:0] in anticipation of the end of a burst transfer. The FREEDM-84A672 completes the burst data transfer and tristates the Rx APPI one RXCLK cycle after RENB is sampled high. Because the burst data transfer is complete and RENB is immediately returned low following selection, the FREEDM-84A672 immediately begins the next data transfer following the single turn-around cycle. The protocol dictates that at least one tristate turn-around cycle be inserted between data transfers, even if the external controller is reselecting the same FREEDM-84A672 device. In other words, Figure 18 shows the earliest possible time that the external controller could have set RENB high to reselect FREEDM84A672 device 0.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
213
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 19 - Receive APPI Timing (Boundary Condition)
RXCLK RXADDR[2:0] RPA RENB RXDATA[15:0] RVAL RSX REOP RMOD RERR CH 2 D0 D1 D2 D3 CH 1 Dev 7 D8 D9 Dev 0 NULL Dev 7 Dev 0 NULL Dev 6 Dev 7 NULL Dev 4 Dev 6 NULL Dev 4 Dev 7 Dev 1 NULL Dev 7 Dev 3 Dev 1 NULL Dev 2 Dev 3 NULL Dev 2
Figure 19 shows the boundary condition where a packet transfer completes shortly after the external controller has set RENB high to pause the FREEDM84A672 device. The second data transfer is the final two words of a packet for FREEDM-84A672 device 7, channel 1. When FREEDM-84A672 device 0 places D2 on RXDATA[15:0], the external controller sets RENB high to pause the FREEDM-84A672 device. In the following RXCLK cycle, the FREEDM-84A672 provides D3 on RXDATA[15:0] and sets REOP high to conclude packet transfer. The external controller samples REOP high while RENB is high and recognizes that the packet transfer is complete. The external controller now knows that it doesn't need to reselect FREEDM-84A672 device 0, but can select another FREEDM-84A672 device sharing the Rx APPI. The external controller decides to select FREEDM-84A672 device 7 by placing this address on the RXADDR[2:0] signals. The external controller sets RENB low to commence data transfer from FREEDM-84A672 device 7.
12.6 Transmit APPI Timing
The transmit Any-PHY packet interface (APPI) timing is shown in Figure 20. An external controller provides data to the FREEDM-84A672 device using the transmit APPI. The following discussion surrounding the transmit APPI functional timing assumes that multiple FREEDM-84A672 devices share a single external controller. The three most significant bits of TXADDR[12:0] perform device selection for purposes of polling while the ten least significant bits provide the channel poll address. All Tx APPI signals are shared between the FREEDM84A672 devices.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
214
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 20 - Transmit APPI Timing (Normal Transfer)
TXCLK TRDY Dev 4 D129
TXDATA[15:0] TSX TEOP TMOD TERR
CH 0
D0
D1
D2
D126
D127
CH 0
D128
D130
D131
D132
D254
D255
Figure 20 shows transfer of a 256 word packet on the Tx APPI of FREEDM84A672 device 4, channel 0. The maximum burst data transfer (excluding channel address prepend) is 128 words, so two data transfers are required to complete the transfer of the 256 word packet. The start of all burst data transfers is qualified with the TSX signal and an in-band channel address on TXDATA[15:0] to associate the data to follow with a HDLC channel. The TEOP signal indicates the end of valid packet data. The TMOD and TERR signals held low except at the end of a packet (TEOP set high). The FREEDM-84A672 starts driving the TRDY signal one TXCLK cycle after TSX is sampled high. Upon sampling the TRDY signal high, the external controller completes the current burst data transfer. The FREEDM-84A672 tristates the TRDY signal one TXCLK cycle after it has been driven high. This is the case for the first burst data transfer in Figure 20. In the second burst data transfer, the FREEDM-84A672 drives the TRDY signal low to indicate that the FIFOs in the TAPI672 are full and no further data may be transferred. Upon sampling the TRDY signal low, the external controller must hold the last valid word of data on TXDATA[15:0]. The FREEDM-84A672 may drive TRDY low for an indeterminate number of TXCLK cycles. During this time, the external controller must wait and is not permitted to begin another burst data transfer until TRDY is sampled high. When the TAPI672 has at least one empty FIFO, the FREEDM-84A672 drives the TRDY signal high. Upon sampling the TRDY signal high, the external controller completes the current burst data transfer. The FREEDM-84A672 tristates the TRDY signal one TXCLK cycle after it has been driven high. The external controller must sample the TRDY signal high before it can begin the next burst data transfer. This prevents the external controller from bombarding the FREEDM-84A672 device with small packets and allows the FREEDM84A672 to perform the necessary house-keeping and clean-up associated with the ending of burst data transfers. This protocol also ensures that transitions between burst data transfers do not require any extra per channel storage, thereby simplifying implementation of both the external controller and the FREEDM-84A672 device. Figure 21 illustrates this condition.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
215
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 21 - Transmit APPI Timing (Special Conditions)
TXCLK TRDY Dev 3 TXDATA[15:0] TSX TEOP TMOD TERR CH 0 D0 CH 671 D0 D1 Dev 5 D2 CH 2 D0
Figure 21 shows two special conditions - (1) the transfer of a one word packet illustrating how the external controller must wait until TRDY has been sampled high before the next data transfer can begin, and (2) the transfer of a packet which completes when TRDY is set low illustrating that although the packet has been completely transferred, the external controller must still wait until TRDY has been sampled high before the next data transfer can begin. The first data transfer is a single word packet for FREEDM-84A672 device 3, channel 0. The FREEDM-84A672 asserts TRDY high one TXCLK cycle after TSX is sampled high. The Tx APPI protocol dictates that the external controller must wait until TRDY is sampled high before beginning the next data transfer for FREEDM-84A672 device 5, channel 671. The external controller must hold the last valid word on TXDATA[15:0] until TRDY is sampled high. In this case, that data is a don't care. The FREEDM-84A672 tristates the TRDY signal one TXCLK cycle after it has been driven high. The second transfer is a three word packet which completes transfer in the same TXCLK cycle that TRDY is sampled low by the external controller. Again, the external controller must hold the last valid word on TXDATA[15:0] until TRDY is sampled high. In this case, that data is D2, the last word of the packet. The FREEDM-84A672 may drive TRDY low for an indeterminate number of TXCLK cycles. During this time, the external controller must wait and is not permitted to begin another burst data transfer until TRDY is sampled high. When the external controller samples TRDY high, the current burst transfer is deemed to be complete and the external controller may begin the next data transfer. The FREEDM-84A672 tristates the TRDY signal one TXCLK cycle after it has been driven high.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
216
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 22 - Transmit APPI Timing (Polling)
TXCLK TXADDR[12:0] TPA1[0] TPA1[1] TPA1[2] TPA2[0] TPA2[1] TPA2[2] CH 671 CH 0 Dev 0 CH 254 CH 671 HUNGRY OK CH 0 STARVE OK Dev 1 CH 8 Dev 0 CH 0 CH 254 STARVE UFLOW HUNGRY OK NULL CH 8 STARVE OK CH 9 HUNGRY OK CH 0 CH 399 CH 0 HUNGRY OK CH 1 HUNGRY OK Dev 1 CH 0 STARVE OK Dev 1 CH 1 HUNGRY OK NULL CH 399 STARVE UFLOW CH 400 STARVE UFLOW
Dev 0 CH 1 CH 255 HUNGRY OK STARVE UFLOW
Polling is completely decoupled from device and channel selection on the Tx APPI. Accordingly, the TXADDR[12:0] signals continue to provide only a poll address for any of the FREEDM-84A672 devices sharing the Tx APPI. The most significant three bits provide the device address and the least significant ten bits provide the channel address. Poll results are returned on the TPAn[2:0] signals. The TPAn[0] bit indicates whether or not space exists in the channel FIFO for data (high means space exists in the channel FIFO) and the TPAn[1] bit indicates whether or not that polled channel FIFO is at risk of underflowing and should be provided data soon (high means the channel FIFO is at risk of underflowing). The TPAn[2] bit indicates whether or not an underflow condition has occurred on the polled channel FIFO (high means an underflow condition occurred on that channel). In Figure 22, channel 671 in device 0 reports that space does not exist for data in the channel FIFO, that there is currently no risk of underflow on that channel (hungry) and that an underflow event has not occurred on this channel since the last poll. Channel 0 in device 0 reports that space exists for data in the channel FIFO, that there is currently a risk of underflow on that channel (starving) and that an underflow event has occurred on this channel since the last poll. Polled results for two channels provide a two fold increase in the polling bandwidth on the Tx APPI to accommodate the high density of 672 channels.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
217
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
13
ABSOLUTE MAXIMUM RATINGS
Maximum rating are the worst case limits that the device can withstand without sustaining permanent damage. They are not indicative of normal operating conditions.
Table 31 - FREEDM-84A672 Absolute Maximum Ratings
Case Temperature under Bias Storage Temperature Supply Voltage (+3.3 Volt VDD3.3) Supply Voltage (+2.5 Volt VDD2.5) Volatge on Any Pin Static Discharge Voltage Latch-Up Current DC Input Current Lead Temperature Absolute Maximum Junction Temperature
-40C to +85C -40C to +125C -0.3V to +4.6V -0.3V to +3.5V -0.3V to VDD3.3 + 0.3V 1000 V 100 mA 20 mA +230C +150C
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
218
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
14
D.C. CHARACTERISTICS (TA = -40C to +85C, VDD3.3 = 3.0 to 3.6 V, VDD2.5 = 2.3 to 2.7 V) Table 32 - FREEDM-84A672 D.C. Characteristics
Symbol
Parameter
Min
Typ
Max
Units
Conditions
VDD3.3 VDD2.5 VIL VIH VOL
3.3V Power Supply 2.5V Power Supply Any-PHY Input Low Voltage Any-PHY Input High Voltage Output or Bidirectional Low Voltage Output or Bidirectional High Voltage Schmitt Triggered Input High Voltage Schmitt Triggered Input Low Voltage Input Low Current Input High Current Input Low Current Input High Current Input Capacitance
3.0 2.3 -0.5 2.0
3.3 2.5
3.6 2.7 0.6 VDD3.3 + 0.5 0.4
Volts Volts Volts Volts Volts
Note 4. Note 4.
IOL = -8 mA for all outputs except TDO where IOL = -4 mA. Note 3. IOH = 8 mA for all outputs except TDO where IOH = 4 mA. Note 3.
VOH
2.4
Volts
VT+ VTIILPU IIHPU IIL IIH CIN
2.0 -0.2 +10 -10 -10 -10 45 0 0 0 5
VDD3.3 + 0.5 0.6 +100 +10 +10 +10
Volts Volts A A A A pF VIL = GND, Notes 1, 3, 4. VIH = VDD, Notes 1, 3 VIL = GND, Notes 2, 3 VIH = VDD, Notes 2, 3 Excludes package. Package typically 2 pF. Note 4. All pins. Excludes package. Package typically 2 pF. Note 4.
COUT
Output Capacitance
5
pF
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
219
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Symbol
Parameter
Min
Typ
Max
Units
Conditions
CIO
Bi-directional Capacitance Pin Inductance Operating Current.
5
pF
All pins. Excludes package. Package typically 2 pF. Note 4. All pins. Note 4. VDD2.5 = 2.7V, Outputs Unloaded. All 3 SPEs on SBI interface active. Note 4.
LPIN IDDOP
2 440
nH mA
Notes on D.C. Characteristics:
1. Input pin or bi-directional pin with internal pull-up resistor. 2. Input pin or bi-directional pin without internal pull-up resistor. 3. Negative currents flow into the device (sinking), positive currents flow out of the device (sourcing). 4. Typical values are given as a design aid. The product is not tested to the typical values given in the data sheet.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
220
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
15
FREEDM-84A672 TIMING CHARACTERISTICS (TA = -40C to +85C, VDD3.3 = 3.0 to 3.6 V, VDD2.5 = 2.3 to 2.7 V) Table 33 - Clocks and SBI Frame Pulse (Figure 23) Symbol Description Min Max Units
REFCLK Frequency REFCLK Duty Cycle FASTCLK Frequency (51.84 MHz) FASTCLK Frequency (44.928 MHz) FASTCLK Frequency (66 MHz) FASTCLK Duty Cycle SYSCLK Frequency SYSCLK Duty Cycle TSC1FP THC1FP TPC1FPOUT C1FP Set-Up Time to REFCLK C1FP Hold Time to REFCLK REFCLK to C1FPOUT Valid
19.44 -50 ppm 40 51.84 -50 ppm 44.928 -50 ppm 66 -50 ppm 40 45 -50 ppm 40 4 1 2
19.44 +50 ppm 60 51.84 +50 ppm 44.928 +50 ppm 66 +50 ppm 60 45 +50 ppm 60
MHz % MHz MHz MHz % MHz % ns ns
20
ns
Notes on Input Timing:
1. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 2. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt point of the input.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
221
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Notes on Output Timing:
1. Output propagation delay time is the time in nanoseconds from the 1.4 Volt point of the reference signal to the 1.4 Volt point of the output. 2. Maximum and minimum output propagation delays are measured with a 100 pF load on the Any-PHY interface outputs, 20 pF load on the TD[2:0] outputs and 50pF load on all other outputs. Maximum propagation delay for TD[2:0] increases by typically 1 ns for each 10 pF of extra load. 3. Output tristate delay is the time in nanoseconds from the 1.4 Volt point of the reference signal to the point where the total current delivered through the output is less than or equal to the leakage current.
Figure 23 - SBI Frame Pulse Timing
REFCLK tS C 1FP C1FP tH C1FP
tP C1FPOUT C1FPO UT
Table 34 - SBI DROP BUS (Figure 24) Symbol Description Min Max Units
tSSBIDROP tHSBIDROP
All SBI DROP BUS Inputs Set-Up Time to REFCLK
4
ns ns
All SBI DROP BUS Inputs Hold Time 1 to REFCLK
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
222
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 24 - SBI DROP BUS Timing
REFCLK
tS SBIDROP DDATA[7:0] DDP, DPL DV5
tH SBIDROP
Table 35 - SBI ADD BUS (Figure 25 to Figure 26) Symbol Description Min Max Units
tSSBIADD tHSBIADD tPAACTIVE tPSBIADD tZSBIADD tPOUTEN
AJUST_REQ Set-Up Time to REFCLK AJUST_REQ Hold Time to REFCLK REFCLK to AACTIVE Valid REFCLK to All SBI ADD BUS Outputs (except AACTIVE) Valid REFCLK to All SBI ADD BUS Outputs (except AACTIVE) Tristate
4 1 2 2 2 18 20 20 15
ns ns ns ns ns ns
ADETECT[1] and ADETECT[0] low to All 0 SBI ADD BUS Outputs (except AACTIVE) Valid ADETECT[1] or ADETECT[0] high to All SBI ADD BUS Outputs (except AACTIVE) Tristate 0
tZOUTEN
15
ns
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
223
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 25 - SBI ADD BUS Timing
REFCLK
tS SIADD AJUST_REQ
tH A BIADD
tP A ACT IVE AACTIVE tP S BIADD ADATA[7:0] ADP, APL, AV5 tZ S BIADD ADATA[7:0] ADP, APL, AV5
Figure 26 - SBI ADD BUS Collision Avoidance Timing
ADETECT[n]
tP OUTEN ADATA[7:0] ADP, APL, AV5
tZ OUTEN
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
224
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 36 - Clock/Data Input (Figure 27) Symbol Description Min Max Units
RCLK[2:0] Frequency RCLK[2:0] Duty Cycle tSRD tHRD RD[2:0] Set-Up Time RD[2:0] Hold Time 40 1 2
51.84 60
MHz % ns ns
Figure 27 - Receive Data Timing
RCLK[n] tS RD RD[n] tH RD
Table 37 - Clock/Data Output (Figure 28) Symbol Description Min Max Units
TCLK[2:0] Frequency TCLK[2:0] Duty Cycle tPTD TCLK[2:0] Low to TD[2:0] Valid 40 3
51.84 60 12
MHz % ns
Figure 28 - Transmit Data Timing
TCLK[n] tP TD TD[n]
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
225
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Table 38 - Any-PHY Packet Interface (Figure 29 to Figure 30) Symbol Description Min Max Units
RXCLK Frequency RXCLK Duty Cycle TXCLK Frequency TXCLK Duty Cycle tSAPPI tHAPPI tPAPPI tZAPPI tZDAPPI All APPI Inputs Set-up time to RXCLK, TXCLK All APPI Inputs Hold time to RXCLK, TXCLK RXCLK, TXCLK to all APPI Outputs Valid RXCLK, TXCLK to APPI Outputs Tristate RXCLK, TXCLK to APPI Outputs Driven
25 40 25 40 4 1 2 2 2
50 60 50 60
MHz % MHz % ns ns
12 12
ns ns ns
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
226
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 29 - Receive Any-PHY Packet Interface Timing
RXCLK
tS APPI RXADDR[2:0] RENB
tH A PP I
tP APPI RPA, RSX, RVAL RXDATA[15:0] RXPRTY, RE RR REOP, RMOD tZ APPI RPA, RSX, RVAL RXDATA[15:0] RXPRTY, RE RR REOP, RMOD RPA, RSX, RVAL RXDATA[15:0] RXPRTY, RE RR REOP, RMOD
tZD APPI
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
227
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 30 - Transmit Any-PHY Packet Interface Timing
TXCLK
TXADDR[12:0] TXDATA[15:0] TXPRTY, TSX TEO P, TMOD TERR
tS A PPI
tH APPI
tP A PPI TPAn[2:0] TRDY tZ A PP I TPAn[2:0] TRDY tZD APP I TPAn[2:0] TRDY
Table 39 - Microprocessor Interface Read Access (Figure 31) Symbol Description Min Max Units
tSAR tHAR tSALR tHALR tVL tVRD tSLR
Address to Valid Read Set-up Time Address to Valid Read Hold Time Address to Latch Set-up Time Address to Latch Hold Time Valid Latch Pulse Width Valid Read Pulse Width Latch to Read Set-up
10 5 10 10 5 100 0
ns ns ns ns ns ns ns
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
228
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Symbol
Description
Min
Max
Units
tHLR tPRD tZRD tPINTH
Latch to Read Hold Valid Read to Valid Data Propagation Delay Valid Read Deasserted to Output Tristate Valid Read Deasserted to INTB High
5 40 20 50
ns ns ns ns
Figure 31 - Microprocessor Read Access Timing
tSAR A[11:2] tS ALR tVL ALE tS (CSB+RDB) tPINTH INTB
LR
Valid
Address
tV tH
RD AR
tH ALR
tHLR
tPRD D[15:0]
tZ RD
Valid Data
Notes on Microprocessor Read Timing:
1. A valid read cycle is defined as a logical OR of the CSB and the RDB signals.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
229
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
2. Microprocessor Interface timing applies to normal mode register accesses only. 3. In non-multiplexed address/data bus applications, ALE should be held high, parameters tSALR, tHALR, tVL, tSLR, and tHLR are not applicable. 4. Parameter tHAR is not applicable if address latching is used.
Table 40 - Microprocessor Interface Write Access (Figure 32) Symbol Description Min Max Units
tSAW tSDW tSALW tHALW tVL tSLW tHLW tHDW tHAW tVWR
Address to Valid Write Set-up Time Data to Valid Write Set-up Time Address to Latch Set-up Time Address to Latch Hold Time Valid Latch Pulse Width Latch to Write Set-up Latch to Write Hold Data to Valid Write Hold Time Address to Valid Write Hold Time Valid Write Pulse Width
10 20 10 10 5 0 5 5 5 20
ns ns ns ns ns ns ns ns ns ns
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
230
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Figure 32 - Microprocessor Write Access Timing
A[7:0] tS ALW tV L ALE tSAW (CSB+WRB)
Valid Address
tH ALW tS LW tHLW
tVWR
tH AW
tS DW D[7:0]
tH DW
Valid Data
Notes on Microprocessor Write Timing:
1. A valid write cycle is defined as a logical OR of the CSB and the WRB signals. 2. Microprocessor Interface timing applies to normal mode register accesses only. 3. In non-multiplexed address/data bus architectures, ALE should be held high, parameters tSALW , tHALW , tVL, tSLW , and tHLW are not applicable. 4. Parameters tHAW and tSAW are not applicable if address latching is used.
Table 41 - JTAG Port Interface (Figure 33) Symbol Description Min Max Units
TCK Frequency TCK Duty Cycle tSTMS tHTMS TMS Set-up time to TCK TMS Hold time to TCK 40 50 50
1 60
MHz % ns ns
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
231
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
Symbol
Description
Min
Max
Units
tSTDI tHTDI tPTDO
TDI Set-up time to TCK TDI Hold time to TCK TCK Low to TDO Valid
50 50 2 60
ns ns ns
Figure 33 - JTAG Port Interface Timing
TCK tS TMS TMS tS TDI TDI tH TDI tH TMS
TCK tP TDO TDO
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
232
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
16
ORDERING AND THERMAL INFORMATION Table 42 - FREEDM-84A672 Ordering Information PART NO. DESCRIPTION
PM7385-BI
352 Enhanced Ball Grid Array (SBGA)
Table 43 - FREEDM-84A672 Thermal Information PART NO. CASE TEMPERATURE Theta Ja Theta Jc
PM7385-BI
-40C to +85C
19 C/W
< 1 C/W
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
233
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
17
MECHANICAL INFORMATION Figure 34 - 352 Pin Enhanced Ball Grid Array (SBGA)
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
234
PM7385 FREEDM-84A672
DATA SHEET PMC-1990114 ISSUE 6 84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER WITH ANY-PHY PACKET INTERFACE
CONTACTING PMC-SIERRA, INC.
PMC-Sierra, Inc. 8555 Baxter Place Burnaby, BC Canada V5A 4V7 Tel: Fax: (604) 415-6000 (604) 415-6200 document@pmc-sierra.com info@pmc-sierra.com apps@pmc-sierra.com http://www.pmc-sierra.com
Document Information: Corporate Information: Application Information: Web Site:
None of the information contained in this document constitutes an express or implied warranty by PMC-Sierra, Inc. as to the sufficiency, fitness or suitability for a particular purpose of any such information or the fitness, or suitability for a particular purpose, merchantability, performance, compatibility with other parts or systems, of any of the products of PMC-Sierra, Inc., or any portion thereof, referred to in this document. PMC-Sierra, Inc. expressly disclaims all representations and warranties of any kind regarding the contents or use of the information, including, but not limited to, express and implied warranties of accuracy, completeness, merchantability, fitness for a particular use, or non-infringement. In no event will PMC-Sierra, Inc. be liable for any direct, indirect, special, incidental or consequential damages, including, but not limited to, lost profits, lost business or lost data resulting from any use of or reliance upon the information, whether or not PMC-Sierra, Inc. has been advised of the possibility of such damage. FREEDM is a trademark of PMC-Sierra, Inc. The technology discussed is protected by one or more of the following Patents: U.S. Patent Nos. 5,640,398 and 6,188,699 Can. Patent No. 2,161,921 Relevant patent applications and other patents may also exist. (c) 2001 PMC-Sierra, Inc PMC-1990114 (R6) Issue date: August 2001
PMC-Sierra, Inc.
8555 Baxter Place Burnaby, BC Canada V5A 4V7 604 .415.6000


▲Up To Search▲   

 
Price & Availability of 1990114

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X